  "$schema": "https://verbaipsa.org/api/v1/schema/stelle-buendel.schema.json",
  "amtlich": false,
  "api_json": "/api/v1/ch/sr-734.2/art-39.json",
  "api_md": "/api/v1/ch/sr-734.2/art-39.md",
  "edition": "Fedlex, Systematische Rechtssammlung des Bundes",
  "edition_id": "fedlex-sr",
  "eid": "art_39",
  "extraktionsregel": "akn-kanon-v1",
  "fassung_kennung": "ch/sr-734.2/2019-06-01/art-39",
  "fassungen": {
    "de": {
      "api_json": "/api/v1/ch/sr-734.2/art-39.de.json",
      "api_md": "/api/v1/ch/sr-734.2/art-39.de.md",
      "fundstelle": "https://www.fedlex.admin.ch/eli/cc/1994/1199_1199_1199/de#art_39",
      "fussnoten": [],
      "kanonische_url": "https://verbaipsa.org/ch/sr-734.2/art-39/de/",
      "num": "Art. 39",
      "quelle_sha": "430ccc9d9b0d655f32b7b916d1ebcecf2b040f80d406ab065b191ff9c10717f9",
      "sha256": "3f7024be0a0b009fdb20ca3199822bb6dc7ca5fef7d6ac2651f4f5babf734ce5",
      "sprache": "de",
      "titel": "Unterirdische Anlagen",
      "url": "/ch/sr-734.2/art-39/de/",
      "wortlaut": "1 Unterirdische Starkstromanlagen müssen allseitig berührungssicher gebaut sein, wenn sie nur über einen vertikalen Einstieg zugänglich sind.\n2 Sind sie nicht berührungssicher, so muss für den Einstieg ein Vorraum vorgesehen werden, der vom Betriebsraum durch eine Türe abgetrennt ist."
    },
    "fr": {
      "api_json": "/api/v1/ch/sr-734.2/art-39.fr.json",
      "api_md": "/api/v1/ch/sr-734.2/art-39.fr.md",
      "fundstelle": "https://www.fedlex.admin.ch/eli/cc/1994/1199_1199_1199/fr#art_39",
      "fussnoten": [],
      "kanonische_url": "https://verbaipsa.org/ch/sr-734.2/art-39/fr/",
      "num": "Art. 39",
      "quelle_sha": "3672d40eae7e89c3bb0db6f28a2940b79c706bd5ab8d742706a11761f9175900",
      "sha256": "5bb47f6a2e57833a42c8dddc63843f719b0df2827690911645667f8068612528",
      "sprache": "fr",
      "titel": "Installations souterraines",
      "url": "/ch/sr-734.2/art-39/fr/",
      "wortlaut": "1 Les installations à courant fort souterraines ayant seulement un accès vertical doivent être protégées de toutes parts des contacts directs.\n2 Si ces installations ne sont pas protégées des contacts directs, on prévoira un local d’accès séparé des locaux de service par une porte."
    },
    "it": {
      "api_json": "/api/v1/ch/sr-734.2/art-39.it.json",
      "api_md": "/api/v1/ch/sr-734.2/art-39.it.md",
      "fundstelle": "https://www.fedlex.admin.ch/eli/cc/1994/1199_1199_1199/it#art_39",
      "fussnoten": [],
      "kanonische_url": "https://verbaipsa.org/ch/sr-734.2/art-39/it/",
      "num": "Art. 39",
      "quelle_sha": "cbbeb2112cf7ad204f0ad24b7acca3177751bb00c0547bfca41fa570e150b563",
      "sha256": "6b67213b0068b44ef63dad5aa2c9a91708039138ed447123f0d74296e0a30a06",
      "sprache": "it",
      "titel": "Impianti sotterranei",
      "url": "/ch/sr-734.2/art-39/it/",
      "wortlaut": "1 Se accessibili solo tramite un accesso verticale, gli impianti sotterranei a corrente forte devono essere costruiti in modo da risultare protetti da ogni lato dal contatto.\n2 Se gli impianti non sono protetti da ogni lato dal contatto, l’accesso deve prevedere un vano d’ingresso separato da una porta dal locale d’esercizio ."
    }
  },
  "id": "ch/sr-734.2/art-39",
  "ist_geltend": true,
  "kanonische_url": "https://verbaipsa.org/ch/sr-734.2/art-39/",
  "kennung": "ch/sr-734.2/art-39",
  "lizenz": "gemeinfrei, Art. 5 URG",
  "schema": 1,
  "sprachen": [
    "de",
    "fr",
    "it"
  ],
  "sr": "734.2",
  "stand": "2019-06-01",
  "stelle": "art-39",
  "typ": "stelle_buendel",
  "url": "/ch/sr-734.2/art-39/",
  "werk_id": "ch/sr-734.2",
  "werk_kennung": "sr-734.2"
}