{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-1.de.json","api_md":"/api/v1/ch/lev/art-1.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_1","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-1","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_1","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_1","num":"1. Kapitel:","titel":"Zweck, Geltungsbereich und Begriffe"}],"id":"ch/lev/art-1","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-1/de/","kennung":"ch/lev/art-1","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 1","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"44cbb03f50eb215dda12bace38243ca9d8060d1576dc62882724e87b9e566d62","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-1","titel":"Zweck","typ":"stelle","url":"/ch/lev/art-1/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Diese Verordnung bezweckt die Vermeidung von Gefahren, die von elektrischen Leitungen sowie von der Annäherung, Parallelführung und Kreuzung elektrischer Leitungen unter sich, mit anderen Anlagen oder mit Bauten ausgehen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-1.fr.json","api_md":"/api/v1/ch/lev/art-1.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_1","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-1","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_1","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_1","num":"1. Kapitel:","titel":"Zweck, Geltungsbereich und Begriffe"}],"id":"ch/lev/art-1","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-1/fr/","kennung":"ch/lev/art-1","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 1","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"80ec723533865c551d2309c69dd8c7d038c63c51824f026464e2a1710b78b7f6","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-1","titel":"But","typ":"stelle","url":"/ch/lev/art-1/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"La présente ordonnance a pour but d’éviter les dangers provoqués par les lignes électriques, notamment par le rapprochement, le parallélisme et le croisement de lignes électriques entre elles, avec d’autres installations ou avec des constructions."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-1.it.json","api_md":"/api/v1/ch/lev/art-1.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_1","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-1","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_1","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_1","num":"1. Kapitel:","titel":"Zweck, Geltungsbereich und Begriffe"}],"id":"ch/lev/art-1","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-1/it/","kennung":"ch/lev/art-1","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 1","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"03f2ad2df69be3acf954ab72c814fe8501f72a3797aba876e0c7f910776e53ae","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-1","titel":"Scopo","typ":"stelle","url":"/ch/lev/art-1/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"La presente ordinanza si propone di ridurre i pericoli che risultano dalla presenza delle linee elettriche, dalla vicinanza, dal parallelismo e dagli incroci delle linee elettriche tra loro, con altri impianti o con fabbricati."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-2.de.json","api_md":"/api/v1/ch/lev/art-2.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_2","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-2","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_2","fussnoten":[{"marker":"5","nummer":5,"text":"Bereinigung gemäss nicht veröffentlichtem BRB vom 19. Dez 1997."},{"marker":"6","nummer":6,"text":"SR 742.141.1"},{"marker":"7","nummer":7,"text":"Eingefügt durch Beilage 2 Ziff. II 4 der V vom 16. Nov. 2011, in Kraft seit 1. Juli 2012 (AS 2011 6233)."}],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_1","num":"1. Kapitel:","titel":"Zweck, Geltungsbereich und Begriffe"}],"id":"ch/lev/art-2","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-2/de/","kennung":"ch/lev/art-2","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 2","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"636d30eac5fac451a7a8dd60d59e90c9372307b9c9fcc6334080b857a0a0ade4","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-2","titel":"Geltungsbereich","typ":"stelle","url":"/ch/lev/art-2/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Diese Verordnung regelt Erstellung, Betrieb und Instandhaltung von elektrischen Leitungen.\n2 Die Bestimmungen für die Erstellung gelten für bestehende Leitungen, wenn:\na. sie vollständig umgebaut werden;\nb. sie in bedeutendem Mass verändert werden und die Erfüllung der Anforderungen weder unverhältnismässig ist noch die Sicherheit wesentlich beeinträchtigt;\nc. sie für Mensch und Umwelt eine drohende Gefahr darstellen oder andere elektrische Anlagen in erheblichem Mass störend beeinflussen;\nd. durch die Erstellung anderer Anlagen Annäherungen, Parallelführungen und Kreuzungen entstehen.\n3 Können einzelne Bestimmungen dieser Verordnung nur unter ausserordentlichen Schwierigkeiten befolgt werden oder erweisen sie sich für die technische Entwicklung oder den Schutz der Umwelt als hinderlich, so kann das Eidgenössische Departement für Umwelt, Verkehr, Energie und Kommunikation (Departement) oder in weniger bedeutenden Fällen die zuständige Kontrollstelle (Art. 21 Elektrizitätsgesetz) auf begründetes Gesuch hin Abweichungen bewilligen.\n4 Für Lichtwellenleiter gelten sinngemäss die Bestimmungen über Schwachstromleitungen.\n5 Diese Verordnung gilt nicht für die elektrischen Anlagen nach Artikel 42 Absatz 1 der Eisenbahnverordnung vom 23. November 1983."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-2.fr.json","api_md":"/api/v1/ch/lev/art-2.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_2","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-2","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_2","fussnoten":[{"marker":"5","nummer":5,"text":"Nouvelle dénomination selon l’ACF du 19 déc. 1997 (non publié)."},{"marker":"6","nummer":6,"text":"RS 742.141.1"},{"marker":"7","nummer":7,"text":"Introduit par l’annexe 2 ch. II 4 de l’O du 16 nov. 2011, en vigueur depuis le 1er juil. 2012 (RO 2011 6233)."}],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_1","num":"1. Kapitel:","titel":"Zweck, Geltungsbereich und Begriffe"}],"id":"ch/lev/art-2","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-2/fr/","kennung":"ch/lev/art-2","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 2","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"e618a772d9e802f6e4c4549042797f7615fe116205063ebfdf0bcf7e5698d42f","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-2","titel":"Champ d’application","typ":"stelle","url":"/ch/lev/art-2/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 La présente ordonnance s’applique à l’établissement, à l’exploitation et à l’entretien des lignes électriques.\n2 Les dispositions relatives à l’établissement des lignes électriques s’appliquent aux lignes existantes:\na. en cas de transformation complète;\nb. en cas de modification importante de ces lignes, à condition que leur application n’exige pas un effort disproportionné et qu’elle n’affecte pas notablement la sécurité;\nc. si lesdites lignes représentent un danger imminent pour l’homme et pour l’environnement ou si elles perturbent notablement d’autres installations électriques;\nd. si la construction d’autres installations crée des rapprochements, des parallélismes ou des croisements.\n3 Si certaines dispositions de la présente ordonnance s’avèrent extraordinairement difficiles à respecter ou si elles entravent le développement technique ou la protection de l’environnement, le Département fédéral de l’environnement, des transports, de l’énergie et de la communication (ci-après département) ou, dans les cas de moindre importance, l’organe de contrôle compétent (art. 21 de la loi sur les installations électriques, LIE) peut, sur demande motivée, consentir des dérogations.\n4 Les dispositions sur les lignes à courant faible sont applicables aux conducteurs à fibres optiques.\n5 La présente ordonnance n’est pas applicable aux installations électriques visées à l’art. 42, al. 1, de l’ordonnance du 23 novembre 1983 sur les chemins de fer."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-2.it.json","api_md":"/api/v1/ch/lev/art-2.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_2","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-2","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_2","fussnoten":[{"marker":"6","nummer":6,"text":"Nuova denominazione giusta il DCF non pubblicato del 19 dic. 1997."},{"marker":"7","nummer":7,"text":"RS 742.141.1"},{"marker":"8","nummer":8,"text":"Introdotto dall’annesso 2 cifra II n. 4 dell’O del 16 nov. 2011, in vigore dal 1° lug. 2012 (RU 2011 6233)."}],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_1","num":"1. Kapitel:","titel":"Zweck, Geltungsbereich und Begriffe"}],"id":"ch/lev/art-2","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-2/it/","kennung":"ch/lev/art-2","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 2","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"c1c8ce3a1578c51ac171c76bd9e583ca05fb6a1fe1ffa52518688e1c9e684e9e","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-2","titel":"Campo di applicazione","typ":"stelle","url":"/ch/lev/art-2/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 La presente ordinanza regola la costruzione, l’esercizio e la manutenzione delle linee elettriche.\n2 Le disposizioni relative alla costruzione valgono per le linee esistenti quando:\na. esse vengono radicalmente ristrutturate;\nb. esse vengono modificate in misura significativa, il soddisfacimento delle esigenze non sia sproporzionato e la sicurezza non ne risulti pregiudicata;\nc. esse presentano un pericolo incombente per l’uomo e l’ambiente o perturbano in modo grave altri impianti elettrici;\nd. in seguito alla costruzione di altri impianti, vengono a crearsi vicinanze, parallelismi ed incroci.\n3 Se singole disposizioni della presente ordinanza possono essere rispettate solo con difficoltà straordinarie, o se esse si rivelano di ostacolo all’evoluzione tecnica o alla protezione dell’ambiente, il Dipartimento federale dell’ambiente, dei trasporti, dell’energia e delle comunicazioni (Dipartimento) o, in casi meno importanti, l’organo di controllo competente (art. 21 della legge sull’elettricità) può, su richiesta motivata, autorizzare deroghe.\n4 Per i cavi a fibre ottiche trovano applicazione, per analogia, le disposizioni relative alle linee a corrente debole.\n5 La presente ordinanza non si applica agli impianti elettrici secondo l’articolo 42 capoverso 1 dell’ordinanza del 23 novembre 1983 sulle ferrovie."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-3.de.json","api_md":"/api/v1/ch/lev/art-3.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_3","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-3","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_3","fussnoten":[{"marker":"8","nummer":8,"text":"SR 734.2"},{"marker":"9","nummer":9,"text":"SR 734.1"},{"marker":"10","nummer":10,"text":"Aufgehoben durch Beilage 2 Ziff. II 4 der V vom 16. Nov. 2011, mit Wirkung seit 1. Juli 2012 (AS 2011 6233)."}],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_1","num":"1. Kapitel:","titel":"Zweck, Geltungsbereich und Begriffe"}],"id":"ch/lev/art-3","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-3/de/","kennung":"ch/lev/art-3","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 3","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"6070a2729fe9582eddb7eedbedead42f3b17d6182d15515c35a1e1faa36da2f5","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-3","titel":"Weitere Vorschriften","typ":"stelle","url":"/ch/lev/art-3/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Für Erstellung, Betrieb und Instandhaltung von elektrischen Leitungen gelten zudem die Bestimmungen der Starkstromverordnung vom 30. März 1994 sowie der Schwachstromverordnung vom 30. März 1994.\n2 …"}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-3.fr.json","api_md":"/api/v1/ch/lev/art-3.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_3","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-3","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_3","fussnoten":[{"marker":"8","nummer":8,"text":"RS 734.2"},{"marker":"9","nummer":9,"text":"RS 734.1"},{"marker":"10","nummer":10,"text":"Abrogé par l’annexe 2 ch. II 4 de l’O du 16 nov. 2011, avec effet au 1er juil. 2012 (RO 2011 6233)."}],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_1","num":"1. Kapitel:","titel":"Zweck, Geltungsbereich und Begriffe"}],"id":"ch/lev/art-3","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-3/fr/","kennung":"ch/lev/art-3","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 3","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"5dc38a385d3d33171f61600187a3ceff5b8c04d4057f70be3b914d88ad7ed729","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-3","titel":"Autres dispositions","typ":"stelle","url":"/ch/lev/art-3/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les dispositions de l’ordonnance du 30 mars 1994 sur le courant fort et celles de l’ordonnance du 30 mars 1994 sur le courant faible sont également valables pour l’établissement, l’exploitation et l’entretien des lignes électriques.\n2 …"}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-3.it.json","api_md":"/api/v1/ch/lev/art-3.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_3","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-3","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_3","fussnoten":[{"marker":"9","nummer":9,"text":"RS 734.2"},{"marker":"10","nummer":10,"text":"RS 734.1"},{"marker":"11","nummer":11,"text":"Abrogato dall’annesso 2 cifra II n. 4 dell’O del 16 nov. 2011, con effetto dal 1° lug. 2012 (RU 2011 6233)."}],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_1","num":"1. Kapitel:","titel":"Zweck, Geltungsbereich und Begriffe"}],"id":"ch/lev/art-3","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-3/it/","kennung":"ch/lev/art-3","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 3","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"67f2db1391a97f59c17c3cc0a6d13c7311f4592465c8f526cdbbab85d44ebff3","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-3","titel":"Altre prescrizioni","typ":"stelle","url":"/ch/lev/art-3/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Per la costruzione, l’esercizio e la manutenzione delle linee elettriche valgono inoltre le disposizioni dell’ordinanza del 30 marzo 1994 sugli impianti elettrici a corrente forte e dell’ordinanza del 30 marzo 1994 sugli impianti elettrici a corrente debole.\n2 …"}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-4.de.json","api_md":"/api/v1/ch/lev/art-4.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_4","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-4","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_4","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_1","num":"1. Kapitel:","titel":"Zweck, Geltungsbereich und Begriffe"}],"id":"ch/lev/art-4","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-4/de/","kennung":"ch/lev/art-4","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 4","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"53beb2a4a93275a31c80c4d49b9342bd6ec2259aac25a2a5d4406e83898dddd0","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-4","titel":"Begriffe","typ":"stelle","url":"/ch/lev/art-4/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Die in dieser Verordnung verwendeten Begriffe sind in Anhang 1 definiert."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-4.fr.json","api_md":"/api/v1/ch/lev/art-4.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_4","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-4","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_4","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_1","num":"1. Kapitel:","titel":"Zweck, Geltungsbereich und Begriffe"}],"id":"ch/lev/art-4","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-4/fr/","kennung":"ch/lev/art-4","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 4","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"4ef907f3757629fc867fac694f5287066714b66072ade4f90edfd58fb7d79cbb","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-4","titel":"Définitions","typ":"stelle","url":"/ch/lev/art-4/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les termes utilisés dans la présente ordonnance sont définis à l’annexe 1."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-4.it.json","api_md":"/api/v1/ch/lev/art-4.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_4","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-4","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_4","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_1","num":"1. Kapitel:","titel":"Zweck, Geltungsbereich und Begriffe"}],"id":"ch/lev/art-4","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-4/it/","kennung":"ch/lev/art-4","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 4","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"047ff702983d1e439d9b41a8e1139cdcdf73f627030d45cec67c9e8e0d88e8ce","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-4","titel":"Definizioni","typ":"stelle","url":"/ch/lev/art-4/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"I concetti utilizzati nella presente ordinanza sono definiti nell’appendice 1."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-5.de.json","api_md":"/api/v1/ch/lev/art-5.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_5","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-5","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_5","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-5","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-5/de/","kennung":"ch/lev/art-5","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 5","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"c4667e6081ca7d4416da4dd2b8a5332c4d169971acac118733c3b35a6651eef0","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-5","titel":"Grundsatz","typ":"stelle","url":"/ch/lev/art-5/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Elektrische Leitungen dürfen bei bestimmungsgemässem Betrieb sowie in voraussehbaren Störfällen weder Personen noch Sachen gefährden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-5.fr.json","api_md":"/api/v1/ch/lev/art-5.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_5","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-5","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_5","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-5","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-5/fr/","kennung":"ch/lev/art-5","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 5","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"23ac232d12634a9e94254b3d0eb9c5c4502a186f785566d19d36b8b3db9f8109","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-5","titel":"Généralités","typ":"stelle","url":"/ch/lev/art-5/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les lignes électriques ne doivent mettre en danger ni les personnes ni les choses, en exploitation normale comme en cas de perturbation prévisible."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-5.it.json","api_md":"/api/v1/ch/lev/art-5.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_5","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-5","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_5","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-5","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-5/it/","kennung":"ch/lev/art-5","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 5","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"4d3442771fc2548c9c2fe51eb17b170ce0d1c130d6300526381bcfdc8b7fb7f0","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-5","titel":"Principio","typ":"stelle","url":"/ch/lev/art-5/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Le linee elettriche, se esercite conformemente al loro scopo o in presenza di guasti prevedibili, non devono mettere in pericolo persone o cose."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-6.de.json","api_md":"/api/v1/ch/lev/art-6.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_6","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-6","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_6","fussnoten":[{"marker":"11","nummer":11,"text":"International Electrotechnical Commission."},{"marker":"12","nummer":12,"text":"Comité Européen de Normalisation ELECtrotechnique."},{"marker":"13","nummer":13,"text":"Die Liste der Titel der Normen sowie deren Texte können kostenlos eingesehen und gegen Bezahlung bezogen werden bei der Schweizerischen Normen-Vereinigung (SNV), Sulzerallee 70, 8404 Winterthur; www.snv.ch ."},{"marker":"14","nummer":14,"text":"Fassung gemäss Anhang Ziff. 5 der V vom 8. Dez. 1997, in Kraft seit 1. Jan. 1998 (AS 1998 54)."},{"marker":"15","nummer":15,"text":"Fassung gemäss Anhang Ziff. 5 der V vom 8. Dez. 1997, in Kraft seit 1. Jan. 1998 (AS 1998 54)."}],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-6","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-6/de/","kennung":"ch/lev/art-6","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 6","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"40513de2a7d47725b0a8f8632c0434a0fad897cab033fb99229bb953eddc28d0","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-6","titel":"Regeln der Technik","typ":"stelle","url":"/ch/lev/art-6/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Wo diese Verordnung keine Vorschriften enthält, gelten die anerkannten Regeln der Technik.\n2 Als anerkannte Regeln der Technik gelten insbesondere die Normen von IEC und CENELEC. Wo international harmonisierte Normen fehlen, gelten die schweizerischen Normen.\n3 Bestehen keine spezifischen technischen Normen, so sind sinngemäss anwendbare Normen oder allfällige technische Weisungen zu berücksichtigen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-6.fr.json","api_md":"/api/v1/ch/lev/art-6.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_6","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-6","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_6","fussnoten":[{"marker":"11","nummer":11,"text":"Commission Électrotechnique Internationale"},{"marker":"12","nummer":12,"text":"Comité européen de normalisation électrotechnique"},{"marker":"13","nummer":13,"text":"La liste des titres des normes ainsi que leur texte peuvent être obtenus auprès de l’Association suisse de normalisation (SNV), Sulzerallee 70, 8404 Winterthour; www.snv.ch."},{"marker":"14","nummer":14,"text":"Nouvelle teneur selon l’annexe ch. 5 de l’O du 8 déc. 1997, en vigueur depuis le 1er janv. 1998 (RO 1998 54)."},{"marker":"15","nummer":15,"text":"Nouvelle teneur selon l’annexe ch. 5 de l’O du 8 déc. 1997, en vigueur depuis le 1er janv. 1998 (RO 1998 54)."}],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-6","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-6/fr/","kennung":"ch/lev/art-6","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 6","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"5962877c5f2f605b6db4b58ed818041fa2f64b2811106649917fb03e6ee2e94f","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-6","titel":"Règles techniques","typ":"stelle","url":"/ch/lev/art-6/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Lorsque la présente ordonnance ne prescrit rien, on s’en tiendra aux règles techniques reconnues.\n2 Sont réputées règles techniques reconnues en particulier les normes internationales harmonisées de la CEI et du CENELEC. À défaut, on s’en tiendra aux normes suisses.\n3 S’il n’existe pas de normes techniques spécifiques, on utilisera les normes applicables par analogie ou les directives techniques éventuelles."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-6.it.json","api_md":"/api/v1/ch/lev/art-6.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_6","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-6","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_6","fussnoten":[{"marker":"12","nummer":12,"text":"Commissione elettrotecnica internazionale."},{"marker":"13","nummer":13,"text":"Comitato europeo di normalizzazione elettrotecnica."},{"marker":"14","nummer":14,"text":"L’elenco dei titoli delle norme e i relativi testi possono essere richiesti all’Associazione svizzera di normalizzazione (SNV), Sulzerallee 70, 8404 Winterthur; www.snv.ch ."},{"marker":"15","nummer":15,"text":"Nuovo testo giusta l’all. n. 5 dell’O dell’8 dic. 1997, in vigore dal 1° gen. 1998 (RU 1998 54)."},{"marker":"16","nummer":16,"text":"Nuovo testo giusta l’all. n. 5 dell’O dell’8 dic. 1997, in vigore dal 1° gen. 1998 (RU 1998 54)."}],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-6","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-6/it/","kennung":"ch/lev/art-6","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 6","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"0d63458e34680d583210a43a75e6a9fd82aa9a146a87e2e274dc4da327ba5328","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-6","titel":"Regole della tecnica","typ":"stelle","url":"/ch/lev/art-6/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Laddove la presente ordinanza non contiene prescrizioni, valgono le regole riconosciute della tecnica.\n2 Per regole riconosciute della tecnica si intendono in particolare le norme della CEI e del CENELEC. In mancanza di norme armonizzate a livello internazionale si applicano le norme svizzere.\n3 Se non esistono norme tecniche specifiche, si prendono in considerazione le norme applicabili per analogia o eventuali istruzioni tecniche."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-7.de.json","api_md":"/api/v1/ch/lev/art-7.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_7","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-7","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_7","fussnoten":[{"marker":"16","nummer":16,"text":"[AS 1997 1008, 2000 762 Ziff. I 6 3012 Ziff. I Art. 34 Abs. 3. AS 2009 6243 Anhang 3 Ziff. I]. Siehe heute: die V vom 25. Nov. 2015 (SR 734.5)."},{"marker":"17","nummer":17,"text":"Eingefügt durch Ziff. 4 des Anhanges der V über die elektromagnetische Verträglichkeit vom 9. April 1997, in Kraft seit 1. Mai 1997 (AS 1997 1008)."}],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-7","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-7/de/","kennung":"ch/lev/art-7","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 7","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"5f1c8248081aad501465fb42266a2ab2e333fddf32c3811add0f4744c9a35b31","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-7","titel":"Störschutz","typ":"stelle","url":"/ch/lev/art-7/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Elektrische Leitungen müssen, soweit dies ohne ausserordentlichen Aufwand möglich ist, so erstellt, geändert und instand gehalten werden, dass sie in allen Betriebszuständen den bestimmungsgemässen Betrieb anderer Stark- oder Schwachstromanlagen und anderer elektrotechnischer Einrichtungen nicht in unzumutbarer Weise stören.\n2 Störungsgefährdete elektrische Leitungen müssen, soweit dies ohne aussergewöhnlichen Aufwand möglich ist, so erstellt, geändert und instand gehalten werden, dass ihr bestimmungsgemässer Betrieb in allen Betriebszuständen nicht durch andere elektrotechnische Anlagen und Einrichtungen in unzumutbarer Weise gestört wird.\n3 Treten trotz Beachtung der anerkannten Regeln der Technik unzumutbare Störungen auf, die nur mit grossem Aufwand beseitigt werden können, so suchen sich die Beteiligten zu verständigen. Kommt keine Einigung zustande, so entscheidet das Departement. Es hört zuvor die beteiligten Kontrollstellen an.\n4 Für die elektromagnetische Verträglichkeit gelten die Bestimmungen der Verordnung vom 9. April 1997 über die elektromagnetische Verträglichkeit."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-7.fr.json","api_md":"/api/v1/ch/lev/art-7.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_7","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-7","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_7","fussnoten":[{"marker":"16","nummer":16,"text":"[RO 1997 1008, 2000 762 ch. I 6 3012 ch. I art. 34 al. 3. RO 2009 6243 annexe 3 ch. I]. Voir actuellement l’O du 25 nov. 2015 (RS 734.5)."},{"marker":"17","nummer":17,"text":"Introduit par l’annexe ch. 4 de l’O du 9 avr. 1997 sur la compatibilité électromagnétique, en vigueur depuis le 1er mai 1997 (RO 1997 1008)."}],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-7","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-7/fr/","kennung":"ch/lev/art-7","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 7","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"2cc5774010b71cab08b2f8b2fd29a9c75f554d81208d1cab2edc5d340358b857","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-7","titel":"Prévention des perturbations","typ":"stelle","url":"/ch/lev/art-7/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Sous réserve de difficultés extraordinaires, les lignes électriques doivent être construites, modifiées et entretenues de façon que, indépendamment de leur état et leur charge, elles ne perturbent de manière inadmissible ni les installations à courant fort ou à courant faible ni les autres équipements électrotechniques, ces installations et ces équipements étant exploités conformément à leur destination.\n2 Sous réserve de difficultés extraordinaires, les lignes électriques susceptibles d’être perturbées doivent être construites, modifiées et entretenues de façon que, exploitées conformément à leur destination et indépendamment de leur état et de leur charge, elles ne puissent être perturbées de manière inadmissible par d’autres installations ou équipements électrotechniques.\n3 Si des perturbations inadmissibles et très difficiles à éliminer surviennent, malgré le respect des règles techniques reconnues, les intéressés cherchent à s’entendre. S’ils n’y parviennent pas, le département tranche. Il consulte au préalable les organes de contrôle compétents.\n4 Les dispositions de l’ordonnance du 9 avril 1997 sur la compatibilité électromagnétique sont applicables."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-7.it.json","api_md":"/api/v1/ch/lev/art-7.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_7","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-7","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_7","fussnoten":[{"marker":"17","nummer":17,"text":"[RU 1997 1008, 2000 I n. 6 3012 I art. 34 cpv. 3. RU 2011 6243 all. 3]. Vedi ora l’O del 25 nov. 2015 (RS 734.5)."},{"marker":"18","nummer":18,"text":"Introdotto dall’all. n. 4 dell’O del 9 apr. 1997 sulla compatibilità elettromagnetica, in vigore dal 1° mag. 1997 (RU 1997 1008)."}],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-7","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-7/it/","kennung":"ch/lev/art-7","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 7","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"2f44f83efdd4a4a3d148b3071cec60e4ca0e78db6cad048a151b25ad9d25274a","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-7","titel":"Protezione dalle perturbazioni","typ":"stelle","url":"/ch/lev/art-7/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 In quanto non ne risultino dispendi straordinari, le linee elettriche devono essere costruite, modificate e mantenute in modo da non perturbare in maniera inammissibile, in qualsiasi condizione d’esercizio, l’esercizio conforme al loro scopo di altri impianti a corrente forte o debole e di altri dispositivi elettrotecnici.\n2 In quanto non ne risultino dispendi straordinari, le linee elettriche esposte al pericolo di perturbazioni devono essere costruite, modificate e mantenute in modo che il loro esercizio conforme allo scopo non venga perturbato in maniera inammissibile, in tutte le condizioni d’esercizio, da altri impianti e dispositivi elettrotecnici.\n3 Se, malgrado l’osservanza delle regole riconosciute della tecnica, si manifestano perturbazioni inammissibili, eliminabili solo con grande dispendio, le parti in causa cercano di mettersi d’accordo. Se nessun accordo può essere raggiunto, decide il Dipartimento. In precedenza, questi consulta gli organi di controllo interessati.\n4 Per la compatibilità elettromagnetica vigono le disposizioni dell’ordinanza del 9 aprile 1997 sulla compatibilità elettromagnetica."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-8.de.json","api_md":"/api/v1/ch/lev/art-8.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_8","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-8","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_8","fussnoten":[{"marker":"18","nummer":18,"text":"Die Bezeichnung der Verwaltungseinheit wurde in Anwendung von Art. 16 Abs. 3 der Publikationsverordnung vom 17. Nov. 2004 (AS 2004 4937) angepasst."}],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-8","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-8/de/","kennung":"ch/lev/art-8","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 8","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"adab0f28fde9b3cfb6faf369226f605b81a9e9ffe5051d5e66b7965b4d3ab617","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-8","titel":"Vermeiden von Beeinflussungen durch Leitungen","typ":"stelle","url":"/ch/lev/art-8/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Bei Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich, mit anderen Anlagen oder mit Bauten sind unzulässige gegenseitige Beeinflussungen oder Beschädigungen zu vermeiden.\n2 Werden elektrische Leitungen mit anderen leitfähigen Systemen parallel geführt, müssen Schutzvorkehren gegen unzulässige induzierte Längsspannungen getroffen werden.\n3 Müssen elektrische Leitungen im Einflussbereich fremder Erdungsanlagen erstellt werden, so sind sie entsprechend den grössten voraussehbaren Spannungen zu isolieren. Über Kabelmäntel und Schutzrohre dürfen keine Fremdströme fliessen.\n4 Sind beim Zusammentreffen von elektrischen Leitungen Sicherungsmassnahmen zu treffen und können sich die Betriebsinhaber über die Verteilung der Kosten nicht einigen, so entscheidet das Bundesamt für Energie (Art. 17 Elektrizitätsgesetz)."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-8.fr.json","api_md":"/api/v1/ch/lev/art-8.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_8","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-8","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_8","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-8","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-8/fr/","kennung":"ch/lev/art-8","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 8","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"335f4ce3cdedb22b10f497945885ecea8d591e15932b6a2a4b3927e03e329e9a","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-8","titel":"Lutte contre les influences des lignes","typ":"stelle","url":"/ch/lev/art-8/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 En cas de rapprochements, de parallélismes ou de croisements de lignes électriques avec d’autres lignes, avec d’autres installations ou avec des constructions, il faut éviter tout dommage et toute influence réciproque inadmissible.\n2 En cas de parallélismes de lignes électriques avec d’autres systèmes conducteurs d’électricité, des mesures de protection doivent être prises contre les composantes longitudinales inadmissibles de tensions induites.\n3 Si des lignes électriques doivent être établies dans la zone d’influence de prises de terre étrangères, on les isolera contre les tensions maximales prévisibles susceptibles d’apparaître. Aucun courant vagabond ne doit pouvoir circuler dans les gaines de câbles ni dans les tuyaux de protection.\n4 Si, en cas de rencontres entre lignes électriques, des mesures de sécurité doivent être prises et que les exploitants n’arrivent pas à s’entendre sur la répartition des coûts, l’Office fédéral de l’énergie tranche (art. 17 LIE)."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-8.it.json","api_md":"/api/v1/ch/lev/art-8.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_8","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-8","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_8","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-8","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-8/it/","kennung":"ch/lev/art-8","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 8","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"ed34154cf186c701412a96958b970b5df423bd8b38a91efe9dceee3cb8c010f2","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-8","titel":"Interferenze esercitate dalle linee elettriche","typ":"stelle","url":"/ch/lev/art-8/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 In caso di vicinanze, parallelismi ed incroci di linee elettriche tra loro, con altri impianti o con fabbricati, occorre evitare interferenze e danni reciproci inammissibili.\n2 In caso di parallelismo di linee elettriche con altri sistemi conduttori, si devono prendere misure protettive contro l’induzione di tensioni longitudinali inammissibili.\n3 Se le linee elettriche devono essere costruite nelle zone di influenza di impianti di messa a terra estranei, esse devono essere dotate di una isolazione commisurata alla tensione massima prevedibile. Occorre badare a che correnti estranee non possano fluire lungo le guaine dei cavi ed i tubi di protezione.\n4 Se, nel caso di incontro di linee elettriche, si rendono necessarie misure di sicurezza e se gli esercenti non riescono a mettersi d’accordo sulla ripartizione delle spese, decide l’Ufficio federale dell’energia (art. 17 della legge sull’elettricità)."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-9.de.json","api_md":"/api/v1/ch/lev/art-9.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_9","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-9","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_9","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-9","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-9/de/","kennung":"ch/lev/art-9","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 9","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"a71796ee6eab2d44cfdb2a9a5ef1ed4c9b687187e57bac1ce2a599d9917ef6d5","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-9","titel":"Verhältnis zu anderen Leitungen oder Infrastrukturanlagen","typ":"stelle","url":"/ch/lev/art-9/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Bei der Projektierung von elektrischen Leitungen muss der Betriebsinhaber die Leitungen und Infrastrukturanlagen im Einflussbereich der geplanten Leitung erheben.\n2 Treffen elektrische Leitungen mit anderen Leitungen, Anlagen oder Objekten zusammen und kann dadurch die Sicherheit beeinträchtigt werden, so muss der Betriebsinhaber der Leitung die Kontrollstelle frühzeitig schriftlich davon in Kenntnis setzen und über die vorgesehenen Schutzmassnahmen orientieren.\n3 Die Kontrollstelle entscheidet über die Zulässigkeit der geplanten Anordnung und über die Schutzmassnahmen.\n4 Die Kontrollstelle kann beim Zusammentreffen von Starkstromleitungen mit anderen Anlagen und Objekten zusätzliche Schutzmassnahmen nach Anhang 2 vorschreiben."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-9.fr.json","api_md":"/api/v1/ch/lev/art-9.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_9","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-9","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_9","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-9","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-9/fr/","kennung":"ch/lev/art-9","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 9","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"00229608030d6ae0e6d92059f888bc6719227855940f1f478290f69d9f865748","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-9","titel":"Rapport avec d’autres lignes ou infrastructures","typ":"stelle","url":"/ch/lev/art-9/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Lors de la planification de lignes électriques, l’exploitant doit prendre en compte les lignes et les infrastructures se trouvant dans la zone d’influence du projet.\n2 Si les lignes électriques rencontrent d’autres lignes, d’autres installations ou d’autres objets et peuvent de ce fait affecter la sécurité, l’exploitant de la ligne doit en informer sans retard l’organe de contrôle par écrit en indiquant les mesures de protection prévues.\n3 L’organe de contrôle décide si la disposition projetée est admissible et si les mesures de protection sont adéquates.\n4 L’organe de contrôle peut, en cas de rencontre de lignes électriques à courant fort avec d’autres installations ou objets, fixer des mesures de protection supplémentaires conformément à l’annexe 2."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-9.it.json","api_md":"/api/v1/ch/lev/art-9.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_9","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-9","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_9","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-9","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-9/it/","kennung":"ch/lev/art-9","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 9","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"949a00712fea48aa2d7b9b1394821324762393b7dec20ff9c50ed01d7a158f19","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-9","titel":"Interrelazione con altre linee o infrastrutture","typ":"stelle","url":"/ch/lev/art-9/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Nella progettazione delle linee elettriche, l’esercente effettua un inventario delle linee e delle infrastrutture esistenti nella zona di influenza della linea progettata.\n2 Se in caso di incontro di linee elettriche con altre linee, impianti od oggetti può risultare una riduzione della sicurezza, l’esercente deve darne tempestiva conoscenza, per iscritto, all’organo di controllo, informandolo delle misure di protezione previste.\n3 L’organo di controllo decide in merito all’ammissibilità della disposizione prevista e delle misure di protezione.\n4 L’organo di controllo può, nel caso di incontro di linee a corrente forte con altri impianti od oggetti, prescrivere misure protettive supplementari secondo l’appendice 2."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-10.de.json","api_md":"/api/v1/ch/lev/art-10.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_10","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-10","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_10","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-10","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-10/de/","kennung":"ch/lev/art-10","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 10","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"7f8cd4d94ef2846105bbf1fe1a4e33e9540236eaf31478c7ccf570d36a1673cc","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-10","titel":"Vorübergehende Gefährdung","typ":"stelle","url":"/ch/lev/art-10/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Entstehen bei Erstellung, Betrieb oder Instandhaltung elektrischer Leitungen, anderer elektrischer Anlagen oder Anlagen wie Bahnen, Luftseilbahnen, Rohrleitungen und Nationalstrassen vorübergehend gegenseitige Gefährdungen, so müssen sich die Betriebsinhaber der beteiligten Anlagen gegenseitig informieren und über die erforderlichen Schutzmassnahmen verständigen.\n2 Der Betriebsinhaber der Leitung meldet der Kontrollstelle das Zusammentreffen und die vereinbarten Schutzmassnahmen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-10.fr.json","api_md":"/api/v1/ch/lev/art-10.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_10","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-10","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_10","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-10","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-10/fr/","kennung":"ch/lev/art-10","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 10","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"b8b5c2d21fa919a44257f2547d76510a8339e723ce51b68006411c8c0c66a266","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-10","titel":"Danger temporaire","typ":"stelle","url":"/ch/lev/art-10/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Si, lors de l’établissement, de l’exploitation ou de l’entretien de lignes électriques à proximité d’autres installations électriques ou de chemins de fer, de téléphériques, de conduites ou de routes nationales, il y a mise en danger réciproque temporaire, les exploitants de toutes les installations concernées doivent s’informer mutuellement et prendre, d’un commun accord, les mesures de protection nécessaires.\n2 L’exploitant de la ligne concernée annonce à l’organe de contrôle la rencontre de sa ligne avec d’autres installations ou d’autres objets, et les mesures de protection conclues."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-10.it.json","api_md":"/api/v1/ch/lev/art-10.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_10","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-10","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_10","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-10","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-10/it/","kennung":"ch/lev/art-10","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 10","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"18e9ac10ea535076bd20ff5b7d0f22bd857e96f6514c3926cad8e6b9362143a0","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-10","titel":"Esposizioni a pericolo transitorie","typ":"stelle","url":"/ch/lev/art-10/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Se nel corso della costruzione, dell’esercizio o della manutenzione di linee elettriche, di altri impianti elettrici o di impianti quali ferrovie, funivie, trasporti in condotta e strade nazionali, sorgono condizioni di pericolo reciproche, gli esercenti degli impianti interessati devono provvedere ad informarsi tra loro e ad accordarsi sulle misure di protezione necessarie.\n2 L’esercente della linea annuncia il caso all’organo di controllo e comunica le misure di protezione concordate."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-11.de.json","api_md":"/api/v1/ch/lev/art-11.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_11","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-11","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_11","fussnoten":[{"marker":"19","nummer":19,"text":"Fassung gemäss Ziff. I der V vom 3. April 2019, in Kraft seit 1. Juni 2019 (AS 2019 1377)."}],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-11","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-11/de/","kennung":"ch/lev/art-11","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 11","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"113a9172203c5705881f8c858741379a42a205b48d1a173def3bde25746e5117","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-11","titel":"Landschafts- und Umweltschutz","typ":"stelle","url":"/ch/lev/art-11/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Beeinträchtigungen des Landschaftsbilds sowie der Natur und Umwelt durch elektrische Leitungen mit einer Nennspannung von 220 kV oder höher können auf Antrag des Betriebsinhabers dieser Leitungen durch Ersatzmassnahmen an Starkstromanlagen Dritter kompensiert werden (Art. 15b Abs. 2 EleG). Der Betriebsinhaber zieht dabei insbesondere die folgenden Ersatzmassnahmen an Leitungen in Betracht:\na. Bündelung;\nb. Umlegung;\nc. Verkabelung;\nd. Rückbau.\n2 Er beteiligt den Dritten angemessen an der Planung und strebt mit seiner Zustimmung einen gemeinsamen Antrag an. Verweigert der Dritte seine Zustimmung, so stellt der Betriebsinhaber allein Antrag.\n3 Er reicht den Antrag sowie sämtliche Unterlagen, die für die Beurteilung der Ersatzmassnahmen notwendig sind, mit seinem Plangenehmigungsgesuch ein.\n4 Sämtliche dem Dritten durch die Ersatzmassnahme entstehenden Nachteile sind unter Vorteilsanrechnung voll zu entschädigen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-11.fr.json","api_md":"/api/v1/ch/lev/art-11.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_11","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-11","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_11","fussnoten":[{"marker":"18","nummer":18,"text":"Nouvelle teneur selon le ch. I de l’O du 3 avr. 2019, en vigueur depuis le 1er juin 2019 (RO 2019 1377)."}],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-11","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-11/fr/","kennung":"ch/lev/art-11","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 11","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"feee7ca89ce90862670180509bc0be66398a5088e5d5e09280a986fe99900690","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-11","titel":"Protection du paysage et de l’environnement","typ":"stelle","url":"/ch/lev/art-11/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Toute atteinte au paysage, à la nature ou à l’environnement par des lignes électriques d’une tension nominale égale ou supérieure à 220 kV peut, sur requête de l’exploitant de ces lignes, être compensée par des mesures de remplacement réalisées sur des installations électriques à courant fort appartenant à un tiers (art. 15b, al. 2, LIE). L’exploitant envisage en particulier les mesures de remplacement suivantes sur les lignes:\na. regroupement;\nb. déplacement;\nc. câblage;\nd. démantèlement.\n2 Il implique de manière appropriée le tiers dans la planification et s’efforce d’aboutir à une requête commune jouissant de l’approbation de celui-ci. Si le tiers refuse de donner son approbation, l’exploitant dépose sa requête seul.\n3 Il dépose la requête, accompagnée de tous les documents nécessaires à l’évaluation des mesures de remplacement, avec sa demande d’approbation des plans.\n4 Tout inconvénient à un tiers résultant de la mesure de remplacement doit être intégralement indemnisé en y imputant les avantages."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-11.it.json","api_md":"/api/v1/ch/lev/art-11.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_11","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-11","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_11","fussnoten":[{"marker":"19","nummer":19,"text":"Nuovo testo giusta la cifra I dell’O del 3 apr. 2019, in vigore dal 1° giu. 2019 (RU 2019 1377)."}],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-11","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-11/it/","kennung":"ch/lev/art-11","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 11","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"5f8eebb035bfe8aff1f6af1fab0853642a52e022e8964f097a16cac5821577f8","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-11","titel":"Protezione del paesaggio e dell’ambiente","typ":"stelle","url":"/ch/lev/art-11/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le deturpazioni del paesaggio, della natura e dell’ambiente provocate da linee elettriche con una tensione nominale pari o superiore a 220 kV, su richiesta del gestore di dette linee possono essere compensate attraverso provvedimenti di sostituzione su impianti a corrente forte di terzi (art. 15b cpv. 2 LIE). Il gestore prende in considerazione in particolare i seguenti provvedimenti di sostituzione sulle linee:\na. raggruppamento;\nb. spostamento;\nc. cablaggio;\nd. smantellamento.\n2 Esso coinvolge adeguatamente il terzo nella pianificazione e previa la sua approvazione mira a una domanda comune. Se il terzo rifiuta di dare la sua approvazione, il gestore presenta la domanda da solo.\n3 Esso presenta la domanda e tutta la documentazione necessaria per la valutazione dei provvedimenti di sostituzione unitamente alla propria domanda di approvazione dei piani.\n4 Tutti gli svantaggi derivanti al terzo dal provvedimento di sostituzione devono essere interamente indennizzati previa detrazione dei vantaggi."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-11a.de.json","api_md":"/api/v1/ch/lev/art-11a.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_11_a","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-11a","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_11_a","fussnoten":[{"marker":"20","nummer":20,"text":"Eingefügt durch Ziff. II 2 der V vom 24. Juni 2009, in Kraft seit 1. Sept. 2009 (AS 2009 3507)."},{"marker":"21","nummer":21,"text":"SR 814.710"}],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-11a","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-11a/de/","kennung":"ch/lev/art-11a","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 11a","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"6e22c134ad3e5ad672b178bc22b6fa7833915f5f227f0c32596f1bba2cbeff18","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-11a","titel":"Schutz vor nichtionisierender Strahlung bei bestehenden Leitungen","typ":"stelle","url":"/ch/lev/art-11a/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Die für die Erteilung einer Baubewilligung oder die Genehmigung von Nutzungsänderungen von Grundstücken zuständige kommunale oder kantonale Behörde muss vor der Erteilung einer Baubewilligung oder der Genehmigung einer Nutzungsänderung die Betreiberin einer Hochspannungsleitung anhören, wenn:\na. die zulässige Nutzung von Flächen in bestehenden Bauzonen so erweitert oder geändert wird, dass neue Orte mit empfindlicher Nutzung (Art. 3 Abs. 3 Bst. a und b der V vom 23. Dez. 1999 über den Schutz vor nichtionisierender Strahlung, NISV) entstehen können innerhalb des Bereiches um eine bestehende Hochspannungsleitung, in welchem der Anlagegrenzwert (Anhang 1 Ziff. 14 NISV) im massgebenden Betriebszustand (Anhang 1 Ziff. 13 NISV) erreicht oder überschritten ist;\nb. Gebäude so erstellt oder geändert werden, dass neue Orte mit empfindlicher Nutzung (Art. 3 Abs. 3 Bst. a und b NISV) innerhalb des Bereiches um eine bestehende Hochspannungsleitung entstehen, in welchem der Anlagegrenzwert (Anhang 1 Ziff. 14 NISV) im massgebenden Betriebszustand (Anhang 1 Ziff. 13 NISV) erreicht oder überschritten ist."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-11a.fr.json","api_md":"/api/v1/ch/lev/art-11a.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_11_a","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-11a","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_11_a","fussnoten":[{"marker":"19","nummer":19,"text":"Introduit par le ch. II 2 de l’O du 24 juin 2009, en vigueur depuis le 1er sept. 2009 (RO 2009 3507)."},{"marker":"20","nummer":20,"text":"RS 814.710"}],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-11a","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-11a/fr/","kennung":"ch/lev/art-11a","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 11a","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"61f82d984202c427d767c7a69545bb0114f54c5c2bf0badecaacf09cbea109ef","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-11a","titel":"Protection contre le rayonnement non ionisant de lignes existantes","typ":"stelle","url":"/ch/lev/art-11a/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"L’autorité communale ou cantonale compétente pour l’octroi d’un permis de construire ou l’approbation du changement d’affectation d’un bien-fonds doit consulter l’exploitant de la ligne à haute tension avant de délivrer le permis de construire ou d’approuver le changement d’affectation si:\na. l’affectation autorisée de surfaces à l’intérieur de zones à bâtir existantes se trouve élargie ou modifiée de telle manière qu’il peut en résulter de nouveaux lieux à utilisation sensible (art. 3, al. 3, let. a et b, de l’O du 23 déc. 1999 sur la protection contre le rayonnement ionisant, ORNI) dans l’aire d’une ligne à haute tension existante où la valeur limite de l’installation (annexe 1, ch. 14, ORNI) est atteinte ou dépassée dans le mode d’exploitation déterminant (annexe 1, ch. 13, ORNI);\nb. des bâtiments sont édifiés ou modifiés de telle manière qu’il en résulte de nouveaux lieux à utilisation sensible (art. 3, al. 3, let. a et b, ORNI) dans l’aire d’une ligne à haute tension existante où la valeur limite (annexe 1, ch. 14, ORNI) est atteinte ou dépassée dans le mode d’exploitation déterminant (annexe 1, ch. 13, ORNI)."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-11a.it.json","api_md":"/api/v1/ch/lev/art-11a.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_11_a","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-11a","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_11_a","fussnoten":[{"marker":"20","nummer":20,"text":"Introdotto dalla cifra II n. 2 dell’O del 24 giu. 2009, in vigore dal 1° set. 2009 (RU 2009 3507)."},{"marker":"21","nummer":21,"text":"RS 814.710"}],"gliederung":[{"ebene":"title","eid":"tit_1","num":"1. Titel:","titel":"Allgemeine Bestimmungen"},{"ebene":"chapter","eid":"tit_1/chap_2","num":"2. Kapitel:","titel":"Sicherheit"}],"id":"ch/lev/art-11a","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-11a/it/","kennung":"ch/lev/art-11a","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 11a","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"88fcfeb4043e5224d1cc59d71bd8cf25c13476eb9c2b043188e33bbaaa0ea1fa","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-11a","titel":"Protezione dalle radiazioni non ionizzanti per le linee esistenti","typ":"stelle","url":"/ch/lev/art-11a/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Prima di rilasciare un permesso di costruzione o approvare modifiche all’utilizzazione di fondi, l’autorità comunale o cantonale competente deve consultare il gestore di una linea ad alta tensione nel caso in cui:\na. l’utilizzazione autorizzata di superfici in zone edificabili esistenti venga estesa o modificata in modo tale da rendere possibili nuovi luoghi a utilizzazione sensibile (art. 3 cpv. 3 lett. a e b dell’O del 23 dic. 1999 sulla protezione dalle radiazioni non ionizzanti, ORNI) nel perimetro di una linea ad alta tensione esistente nel quale è raggiunto o superato il valore limite dell’impianto (all. 1 n. 14 ORNI) nello stato di esercizio determinante (all. 1 n. 13 ORNI);\nb. vengano costruiti o modificati edifici in modo tale da creare nuovi luoghi a utilizzazione sensibile (art. 3 cpv. 3 lett. a e b ORNI) nel perimetro di una linea ad alta tensione esistente nel quale è raggiunto o superato il valore limite dell’impianto (all. 1 n. 14 ORNI) nello stato di esercizio determinante (all. 1 n. 13 ORNI)."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-11b.de.json","api_md":"/api/v1/ch/lev/art-11b.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_11_b","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-11b","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_11_b","fussnoten":[{"marker":"23","nummer":23,"text":"Fassung gemäss Ziff. I der V vom 4. Juni 2021, in Kraft seit 1. Juli 2021 (AS 2021 330)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1","num":"1. Kapitel:","titel":"Anzuwendende Übertragungstechnologie"}],"id":"ch/lev/art-11b","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-11b/de/","kennung":"ch/lev/art-11b","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 11b","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"c6bf6fae093013c2cdc283a6789a730e36962d74e50492037dc46740db6a49f7","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-11b","titel":"Grundsatz","typ":"stelle","url":"/ch/lev/art-11b/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Ob ein Vorhaben an einer Leitung mit einer Nennspannung von unter 220 kV und einer Frequenz von 50 Hz als Erdkabel oder als Freileitung auszuführen ist, bestimmt sich insbesondere nach Artikel 15c des Elektrizitätsgesetzes sowie nach den Bestimmungen dieses Kapitels.\n2 Der Mehrkostenfaktor gemäss Artikel 15c Absatz 2 des Elektrizitätsgesetzes beträgt 2,0."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-11b.fr.json","api_md":"/api/v1/ch/lev/art-11b.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_11_b","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-11b","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_11_b","fussnoten":[{"marker":"22","nummer":22,"text":"Nouvelle teneur selon le ch.I de l’O du 4 juin 2021, en vigueur depuis le 1er juil. 2021 (RO 2021 330)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1","num":"1. Kapitel:","titel":"Anzuwendende Übertragungstechnologie"}],"id":"ch/lev/art-11b","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-11b/fr/","kennung":"ch/lev/art-11b","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 11b","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"08050711bf97dc8f37d8a2e0d99bdfcf54fb88ba0052815223a2e4c83be1ed1a","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-11b","titel":"Principe","typ":"stelle","url":"/ch/lev/art-11b/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 La réalisation d’un projet concernant une ligne d’une tension nominale inférieure à 220 kV et ayant une fréquence de 50 Hz sous forme de ligne souterraine ou de ligne aérienne est déterminée en particulier sur la base de l’art. 15c LIE et des dispositions du présent chapitre.\n2 Le facteur de surcoût visé à l’art. 15c, al. 2, LIE s’élève à 2,0."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-11b.it.json","api_md":"/api/v1/ch/lev/art-11b.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_11_b","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-11b","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_11_b","fussnoten":[{"marker":"23","nummer":23,"text":"Nuovo testo giusta la cifra I dell’O del 4 giu. 2021, in vigore dal 1° lug. 2021 (RU 2021 330)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1","num":"1. Kapitel:","titel":"Anzuwendende Übertragungstechnologie"}],"id":"ch/lev/art-11b","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-11b/it/","kennung":"ch/lev/art-11b","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 11b","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"4604ba569f85eba546621f47c1148414428c498a4b39664df618ead7ad3cadea","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-11b","titel":"Principio","typ":"stelle","url":"/ch/lev/art-11b/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 La decisione se eseguire un progetto riguardante una linea con tensione nominale inferiore a 220 kV e una frequenza di 50 Hz come cavo interrato o come linea aerea è determinata in particolare secondo l’articolo 15c della legge sugli impianti elettrici e le disposizioni del presente capitolo.\n2 Il fattore dei costi aggiuntivi conformemente all’articolo 15c capoverso 2 della legge sugli impianti elettrici ammonta a 2,0."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-11c.de.json","api_md":"/api/v1/ch/lev/art-11c.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_11_c","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-11c","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_11_c","fussnoten":[{"marker":"24","nummer":24,"text":"SR 734.71"}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1","num":"1. Kapitel:","titel":"Anzuwendende Übertragungstechnologie"}],"id":"ch/lev/art-11c","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-11c/de/","kennung":"ch/lev/art-11c","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 11c","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"3bd1bf1303d9d3fa1d442f5f889b2a7ac3a8930adc0b052d41fb3cec90fa0bb4","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-11c","titel":"Ermittlung des Mehrkostenfaktors eines konkreten Vorhabens","typ":"stelle","url":"/ch/lev/art-11c/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Der Mehrkostenfaktor eines konkreten Vorhabens wird aus dem Verhältnis der voraussichtlichen Gesamtkosten der Ausführung des Vorhabens als Erdkabel zu den voraussichtlichen Gesamtkosten der Ausführung als Freileitung ermittelt.\n2 Zu den voraussichtlichen Gesamtkosten gehören die folgenden Kosten im Zusammenhang mit dem Vorhaben:\na. Planungskosten;\nb. Kosten für den Grunderwerb und die Einräumung von Rechten und Dienstbarkeiten;\nc. Kosten für Wiederherstellungs- und Ersatzmassnahmen;\nd. Kosten für Material;\ne. Bau- und Montagekosten;\nf. Kosten für den Rückbau von bestehenden Leitungen;\ng. Kosten für Instandhaltung und Reparatur;\nh. Kosten für den Ersatz einzelner Komponenten;\ni. Kosten der Energieverluste.\n3 Die voraussichtlichen Gesamtkosten sind über einen Zeitraum zu ermitteln, welcher der Lebensdauer der langlebigsten Komponente der zu vergleichenden Ausführungen entspricht.\n4 Die Kosten nach Absatz 2 sind unter Anwendung der Kapitalwertmethode zu bewerten. Dabei ist ein Diskontierungssatz einzusetzen, der dem durchschnittlichen Kapitalkostensatz nach Artikel 13 Absatz 3 Buchstabe b der Stromversorgungsverordnung vom 14. März 2008, abzüglich des im Zeitpunkt des Vergleichs geltenden Teuerungssatzes der Konsumentenpreise, entspricht.\n5 Für die Ermittlung der Kosten der Energieverluste ist der Preis des langfristigsten Future-Produkts für Lieferverträge für Strom am schweizerischen Terminmarkt zu verwenden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-11c.fr.json","api_md":"/api/v1/ch/lev/art-11c.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_11_c","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-11c","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_11_c","fussnoten":[{"marker":"23","nummer":23,"text":"RS 734.71"}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1","num":"1. Kapitel:","titel":"Anzuwendende Übertragungstechnologie"}],"id":"ch/lev/art-11c","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-11c/fr/","kennung":"ch/lev/art-11c","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 11c","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"49ab9649da73e489e15a6d769ac0ed27b47a84490733e8c70a29a4e37757a4ce","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-11c","titel":"Calcul du facteur de surcoût d’un projet concret","typ":"stelle","url":"/ch/lev/art-11c/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Le facteur de surcoût d’un projet concret est calculé à partir du rapport entre les coûts totaux présumés pour la réalisation du projet sous forme de ligne souterraine et les coûts totaux présumés pour la réalisation sous forme de ligne aérienne.\n2 Les coûts totaux présumés englobent les coûts suivants en lien avec le projet:\na. coûts de planification;\nb. coûts d’acquisition des terrains et de concession de droits et de servitudes;\nc. coûts des mesures de reconstitution et de remplacement;\nd. coûts de matériel;\ne. coûts de construction et de montage;\nf. coûts de démantèlement des lignes existantes;\ng. coûts de maintenance et de réparation;\nh. coûts de remplacement de différents composants;\ni. coûts des pertes d’énergie.\n3 Les coûts totaux présumés sont calculés sur une période correspondant à la durée de vie des composants les plus durables des réalisations comparées.\n4 Les coûts visés à l’al. 2 sont évalués au moyen de la méthode de la valeur actualisée nette. L’évaluation fait appel à un taux d’actualisation correspondant au coût moyen pondéré du capital visé à l’art. 13, al. 3, let. b, de l’ordonnance du 14 mars 2008 sur l’approvisionnement en électricité, déduction faite du taux de renchérissement des prix à la consommation en vigueur au moment de la comparaison.\n5 Le calcul des coûts des pertes d’énergie fait appel au prix du produit dans les contrats dont l’échéance est la plus éloignée conclus sur le marché à terme suisse et portant sur la livraison d’électricité."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-11c.it.json","api_md":"/api/v1/ch/lev/art-11c.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_11_c","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-11c","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_11_c","fussnoten":[{"marker":"24","nummer":24,"text":"RS 734.71"}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1","num":"1. Kapitel:","titel":"Anzuwendende Übertragungstechnologie"}],"id":"ch/lev/art-11c","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-11c/it/","kennung":"ch/lev/art-11c","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 11c","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"265599f9c18e3bda264b9e7f7902d766bb1b5799a96024a12e873c21f96efa96","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-11c","titel":"Determinazione del fattore dei costi aggiuntivi di un progetto concreto","typ":"stelle","url":"/ch/lev/art-11c/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Il fattore dei costi aggiuntivi di un progetto concreto è determinato dal rapporto tra i costi complessivi previsti per l’esecuzione della variante con cavi interrati e i costi complessivi previsti per l’esecuzione della variante con linee aeree.\n2 I costi complessivi previsti comprendono i costi di progetto relativi a:\na. pianificazione;\nb. acquisto del fondo e concessione di diritti e servitù;\nc. provvedimenti di sostituzione e di ripristino;\nd. materiale;\ne. costruzione e montaggio;\nf. smantellamento delle linee esistenti;\ng. manutenzione e riparazione;\nh. sostituzione di singoli componenti;\ni. perdite di energia.\n3 I costi complessivi previsti sono determinati per un periodo che corrisponde alla durata di vita dei componenti più longevi delle varianti da confrontare.\n4 I costi di cui al capoverso 2 sono valutati attraverso il metodo del valore attuale netto. Nel fare ciò si applica un tasso di attualizzazione corrispondente al costo medio ponderato del capitale secondo l’articolo 13 capoverso 3 lettera b dell’ordinanza del 14 marzo 2008 sull’approvvigionamento elettrico, dedotto il tasso di rincaro dei prezzi al consumo applicabile al momento del confronto.\n5 I costi provocati dalle perdite di energia sono determinati sulla base del prezzo del prodotto future a lungo termine per i contratti di fornitura di elettricità sul mercato svizzero a termine."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-11d.de.json","api_md":"/api/v1/ch/lev/art-11d.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_11_d","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-11d","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_11_d","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1","num":"1. Kapitel:","titel":"Anzuwendende Übertragungstechnologie"}],"id":"ch/lev/art-11d","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-11d/de/","kennung":"ch/lev/art-11d","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 11d","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"a94b65d966dbac8ba6de74c4c671d7bb07dfe5cb838e286b57d40f43f1c4d112","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-11d","titel":"Einhaltung des Mehrkostenfaktors","typ":"stelle","url":"/ch/lev/art-11d/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Ist der Mehrkostenfaktor eines konkreten Vorhabens nicht grösser als der Mehrkostenfaktor nach Artikel 11b, so ist das Vorhaben als Erdkabel auszuführen.\n2 Das Vorhaben ist trotz Einhaltung des Mehrkostenfaktors als Freileitung auszuführen, sofern:\na. das Vorhaben eine bestehende Freileitung betrifft und nicht mehr als vier Spannweiten umfasst; oder\nb. die vom Vorhaben betroffene Leitung mit einer bestehenden Freileitung gebündelt werden kann, deren Nennspannung gleich oder höher ist als diejenige der vom Vorhaben betroffenen Leitung."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-11d.fr.json","api_md":"/api/v1/ch/lev/art-11d.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_11_d","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-11d","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_11_d","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1","num":"1. Kapitel:","titel":"Anzuwendende Übertragungstechnologie"}],"id":"ch/lev/art-11d","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-11d/fr/","kennung":"ch/lev/art-11d","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 11d","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"edb3a518896a5382978a88cf932ec240a036767a695978f94aaf65b7e5832bee","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-11d","titel":"Respect du facteur de surcoût","typ":"stelle","url":"/ch/lev/art-11d/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Si le facteur de surcoût d’un projet concret ne dépasse pas le facteur de surcoût visé à l’art. 11b, le projet doit être réalisé sous forme de ligne souterraine.\n2 Le projet est réalisé sous forme de ligne aérienne malgré le respect du facteur de surcoût:\na. s’il concerne une ligne aérienne existante et s’étend sur quatre portées au maximum, ou\nb. si la ligne concernée par le projet peut être regroupée avec une ligne aérienne existante dont la tension nominale est supérieure ou égale à celle de la ligne concernée par le projet."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-11d.it.json","api_md":"/api/v1/ch/lev/art-11d.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_11_d","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-11d","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_11_d","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1","num":"1. Kapitel:","titel":"Anzuwendende Übertragungstechnologie"}],"id":"ch/lev/art-11d","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-11d/it/","kennung":"ch/lev/art-11d","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 11d","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"4b62e753d58f3c4d50ec833a3f0efb49a8dfa00596a2f387da0cef6516bfd1ed","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-11d","titel":"Rispetto del fattore dei costi aggiuntivi","typ":"stelle","url":"/ch/lev/art-11d/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Se il fattore dei costi aggiuntivi di un progetto concreto non supera il fattore dei costi aggiuntivi secondo l’articolo 11b, il progetto è eseguito con cavi interrati.\n2 Il progetto è eseguito con linee aeree nonostante il rispetto del fattore dei costi aggiuntivi se:\na. riguarda una linea aerea esistente e comprende non più di quattro campate; oppure\nb. la linea interessata dal progetto può essere raggruppata con una linea aerea esistente, la cui tensione nominale è uguale o superiore a quella della linea interessata dal progetto."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-11e.de.json","api_md":"/api/v1/ch/lev/art-11e.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_11_e","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-11e","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_11_e","fussnoten":[{"marker":"25","nummer":25,"text":"Fassung gemäss Ziff. I der V vom 4. Juni 2021, in Kraft seit 1. Juli 2021 (AS 2021 330)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1","num":"1. Kapitel:","titel":"Anzuwendende Übertragungstechnologie"}],"id":"ch/lev/art-11e","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-11e/de/","kennung":"ch/lev/art-11e","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 11e","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"31235fdba0d340703adf2c42f216d3a8866fa8f836b87d377b8a3fbf42a72be1","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-11e","titel":"Überschreitung des Mehrkostenfaktors","typ":"stelle","url":"/ch/lev/art-11e/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Ein konkretes Vorhaben kann trotz Überschreitung des Mehrkostenfaktors teilweise oder vollständig als Erdkabel ausgeführt werden, wenn der Betriebsinhaber im Plangenehmigungsverfahren nachweist, dass ein Dritter die den Mehrkostenfaktor überschreitenden Kosten trägt."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-11e.fr.json","api_md":"/api/v1/ch/lev/art-11e.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_11_e","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-11e","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_11_e","fussnoten":[{"marker":"24","nummer":24,"text":"Nouvelle teneur selon le ch.I de l’O du 4 juin 2021, en vigueur depuis le 1er juil. 2021 (RO 2021 330)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1","num":"1. Kapitel:","titel":"Anzuwendende Übertragungstechnologie"}],"id":"ch/lev/art-11e","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-11e/fr/","kennung":"ch/lev/art-11e","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 11e","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"987cd83f759846ca9844e311a50b47e0cf46487f7eefffb93a2c5dbfb45feba7","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-11e","titel":"Dépassement du facteur de surcoût","typ":"stelle","url":"/ch/lev/art-11e/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Un projet concret peut, malgré le dépassement du facteur de surcoût, être réalisé partiellement ou intégralement sous forme de ligne souterraine si, lors de la procédure d’approbation des plans, l’exploitant démontre qu’un tiers prend en charge le montant dépassant le facteur de surcoût fixé."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-11e.it.json","api_md":"/api/v1/ch/lev/art-11e.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_11_e","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-11e","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_11_e","fussnoten":[{"marker":"25","nummer":25,"text":"Nuovo testo giusta la cifra I dell’O del 4 giu. 2021, in vigore dal 1° lug. 2021 (RU 2021 330)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1","num":"1. Kapitel:","titel":"Anzuwendende Übertragungstechnologie"}],"id":"ch/lev/art-11e","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-11e/it/","kennung":"ch/lev/art-11e","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 11e","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"4f63ac138038e174759a2936129712da881b3987cdcca2a034cb2100ca4430c8","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-11e","titel":"Superamento del fattore dei costi aggiuntivi","typ":"stelle","url":"/ch/lev/art-11e/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Un progetto concreto può essere eseguito parzialmente o interamente con cavi interrati nonostante il superamento del fattore dei costi aggiuntivi, se nell’ambito della procedura d’approvazione dei piani l’esercente dimostra che un terzo si assume l’importo eccedente il fattore dei costi aggiuntivi."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-12.de.json","api_md":"/api/v1/ch/lev/art-12.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_12","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-12","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_12","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-12","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-12/de/","kennung":"ch/lev/art-12","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 12","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"e02a4012c6a3c33375b708428ea0979e90a4bdce04ccc52f196a9da214e4dfc4","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-12","titel":"Leitungsführung","typ":"stelle","url":"/ch/lev/art-12/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Leitungen sind so zu erstellen, dass sie auch bei starkem Wind oder Schneefall nicht durch Bäume und Sträucher beeinträchtigt werden.\n2 Leiter dürfen nur an den für sie erstellten und zugelassenen Tragwerken befestigt werden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-12.fr.json","api_md":"/api/v1/ch/lev/art-12.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_12","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-12","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_12","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-12","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-12/fr/","kennung":"ch/lev/art-12","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 12","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"d5374f9615969ea73b8df28e0ae4072934dabd1e222ef7b5ccec48644673a38a","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-12","titel":"Tracé de la ligne","typ":"stelle","url":"/ch/lev/art-12/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les lignes doivent être établies de façon à ne pas pouvoir être endommagées par des arbres ni par des buissons, même lors de vents violents ou de fortes chutes de neige.\n2 Les conducteurs doivent être fixés uniquement sur des supports admis et établis pour eux."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-12.it.json","api_md":"/api/v1/ch/lev/art-12.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_12","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-12","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_12","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-12","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-12/it/","kennung":"ch/lev/art-12","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 12","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"d7579d928128c08502c603465adeaa7b408c74e3278db771ac4cf406fd8e23c8","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-12","titel":"Tracciato","typ":"stelle","url":"/ch/lev/art-12/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le linee devono essere costruite in modo da non poter venire danneggiate da alberi o arbusti, anche in presenza di forte vento o di neve.\n2 I conduttori delle linee possono essere fissati esclusivamente ai sostegni all’uopo autorizzati e costruiti."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-13.de.json","api_md":"/api/v1/ch/lev/art-13.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_13","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-13","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_13","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-13","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-13/de/","kennung":"ch/lev/art-13","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 13","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"4978742335befb7770e71f42a0b805964b24d22692ec3e13c92e090bcea9805b","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-13","titel":"Abstand der Leiter unter sich und zu den Tragwerken","typ":"stelle","url":"/ch/lev/art-13/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Der Abstand der Leiter unter sich und zu den Tragwerken muss so bemessen sein, dass Kurzschlüsse auch bei ausserordentlichen Bewegungen der Leiter (Windauslenkung, Abwurf von Zusatzlasten) ausgeschlossen sind."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-13.fr.json","api_md":"/api/v1/ch/lev/art-13.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_13","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-13","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_13","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-13","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-13/fr/","kennung":"ch/lev/art-13","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 13","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"a3163e86213f687e9b005f714e9c17801933caf52b36e2dd1c500300b82b64a2","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-13","titel":"Distance entre les conducteurs et entre les conducteurs et les supports","typ":"stelle","url":"/ch/lev/art-13/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"La distance entre les conducteurs et entre les conducteurs et les supports doit être fixée de façon que les courts-circuits soient exclus, même en cas de mouvements extraordinaires des conducteurs (déviation due au vent, chute de surcharges)."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-13.it.json","api_md":"/api/v1/ch/lev/art-13.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_13","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-13","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_13","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-13","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-13/it/","kennung":"ch/lev/art-13","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 13","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"8cfceca4a3c60104cc0b3a289effa968f9adf097fb6afbf494bb6eaca82d1815","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-13","titel":"Distanze dei conduttori tra loro e dai sostegni","typ":"stelle","url":"/ch/lev/art-13/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Le distanze dei conduttori tra loro e dai sostegni vanno fissate in modo da escludere cortocircuiti anche in seguito a spostamenti straordinari dei conduttori (spostamenti sotto la spinta del vento, caduta del sovraccarico)."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-14.de.json","api_md":"/api/v1/ch/lev/art-14.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_14","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-14","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_14","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-14","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-14/de/","kennung":"ch/lev/art-14","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 14","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"1803670f56e9b4e6f3f2c94a7a2bc8a7c7a069bce2aa20b6d966cb1a3cab75f2","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-14","titel":"Abstand zum Boden","typ":"stelle","url":"/ch/lev/art-14/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Leiter und Luftkabel müssen sowohl beim grössten Durchhang wie auch bei Windauslenkung mindestens die Bodenabstände nach Anhang 3 aufweisen.\n2 Bei im Winter benutzbaren Transportwegen, bei markierten Skipisten und bei viel begangenen Wanderwegen sind auch die mittleren Schneehöhen zu berücksichtigen.\n3 Die Kontrollstelle kann in begründeten Ausnahmefällen kleinere Abstände bewilligen. Sie bestimmt dabei die zu treffenden Schutzmassnahmen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-14.fr.json","api_md":"/api/v1/ch/lev/art-14.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_14","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-14","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_14","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-14","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-14/fr/","kennung":"ch/lev/art-14","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 14","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"374566b31315e2ebfe076ef6ab9d5ff8afbc53d9710299a357a8fb4aae7d2b01","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-14","titel":"Distance entre les lignes et le sol","typ":"stelle","url":"/ch/lev/art-14/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les distances minimales entre les conducteurs et les câbles aériens et le sol, aussi bien pour la flèche maximale que pour la déviation due au vent, sont données à l’annexe 3.\n2 On tiendra compte des hauteurs moyennes de la neige pour les pistes de ski, les chemins carrossables en hiver et les chemins touristiques très fréquentés.\n3 Dans certains cas exceptionnels justifiés, l’organe de contrôle peut autoriser des distances inférieures. Il fixe alors les mesures de protection à prendre."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-14.it.json","api_md":"/api/v1/ch/lev/art-14.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_14","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-14","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_14","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-14","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-14/it/","kennung":"ch/lev/art-14","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 14","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"dcde157adad29b48b464cc60685045e308fe77f486e2746f614fed290fa9306d","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-14","titel":"Distanza dal suolo","typ":"stelle","url":"/ch/lev/art-14/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 In presenza della freccia massima o sotto la spinta del vento, la distanza dal suolo di conduttori e cavi aerei non deve scendere al disotto del valori di cui all’appendice 3.\n2 Per i percorsi usati in inverno per i trasporti, le piste di sci contrassegnate ed i sentieri molto frequentati, nell’osservanza della distanza minima dal suolo si deve tener conto anche dell’altezza media della coltre nevosa.\n3 L’organo di controllo può autorizzare, in casi eccezionali motivati, distanze più piccole. Esso definisce, in tal caso, le misure di protezione da applicare."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-15.de.json","api_md":"/api/v1/ch/lev/art-15.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_15","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-15","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_15","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-15","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-15/de/","kennung":"ch/lev/art-15","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 15","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"a04f1e4019694499a9917ed925a58f023a453479c510aa4608d82f33e5d1fbcf","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-15","titel":"Abstand zu Bäumen","typ":"stelle","url":"/ch/lev/art-15/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Bäume unter oder neben Leitungen sind zurückzuschneiden oder zu beseitigen, wenn dies zum Schutz der Personen, welche die Bäume besorgen, oder zur Gewährleistung der Betriebssicherheit der Leitung notwendig ist."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-15.fr.json","api_md":"/api/v1/ch/lev/art-15.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_15","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-15","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_15","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-15","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-15/fr/","kennung":"ch/lev/art-15","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 15","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"0325f9ea62ae934dad23f0d695a40f8386af39fa6f1104315f5955a0bbed2e38","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-15","titel":"Distance entre les lignes et les arbres","typ":"stelle","url":"/ch/lev/art-15/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les arbres situés sous les lignes ou à proximité des lignes doivent être abattus ou suffisamment élagués pour garantir à la fois la protection des personnes assurant l’entretien des arbres et la sécurité de l’exploitation de la ligne."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-15.it.json","api_md":"/api/v1/ch/lev/art-15.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_15","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-15","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_15","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-15","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-15/it/","kennung":"ch/lev/art-15","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 15","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"6dd2048e6773bd2b5c80eee73b630e8ecef6ab739d734419f1864a4e81701f0a","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-15","titel":"Distanza dagli alberi","typ":"stelle","url":"/ch/lev/art-15/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Gli alberi sotto o accanto alle linee vanno rimossi o potati qualora ciò sia necessario per la protezione delle persone occupate alla cura degli alberi stessi o per garantire la sicurezza d’esercizio della linea."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-16.de.json","api_md":"/api/v1/ch/lev/art-16.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_16","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-16","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_16","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-16","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-16/de/","kennung":"ch/lev/art-16","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 16","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"33f1e8b6fddc1560f2776eda023544437c1a9915ff3f9184002d0d6e12b1e1f3","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-16","titel":"Abstand zu Gewässern","typ":"stelle","url":"/ch/lev/art-16/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Für den Abstand von Schwachstromfreileitungen zu Gewässern gilt Artikel 40."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-16.fr.json","api_md":"/api/v1/ch/lev/art-16.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_16","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-16","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_16","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-16","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-16/fr/","kennung":"ch/lev/art-16","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 16","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"dddcdc58b2f88f3fa76c5be6f6818cb45c4517de0b71250986d65687912868e1","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-16","titel":"Distance entre les lignes et les cours d’eau","typ":"stelle","url":"/ch/lev/art-16/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les distances entre les lignes aériennes à courant faible et les cours d’eau sont régies par l’art. 40."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-16.it.json","api_md":"/api/v1/ch/lev/art-16.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_16","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-16","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_16","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-16","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-16/it/","kennung":"ch/lev/art-16","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 16","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"4fe4be204087ab534ded761e58c2c21f06936c1652da02614855bef6e39a4934","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-16","titel":"Distanza dalle acque","typ":"stelle","url":"/ch/lev/art-16/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Per quanto concerne la distanza delle linee aeree a corrente debole dalle acque trova applicazione l’articolo 40."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-17.de.json","api_md":"/api/v1/ch/lev/art-17.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_17","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-17","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_17","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-17","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-17/de/","kennung":"ch/lev/art-17","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 17","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"e587fa4d48afcde37502b2d7bd189146ae92ce5d60af87ef59091482ea700cca","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-17","titel":"Leiter und Tragelemente von Luftkabeln","typ":"stelle","url":"/ch/lev/art-17/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Die Beanspruchung der Leiter und Tragelemente darf die höchstzulässige Zugbeanspruchung der verwendeten Werkstoffe nicht überschreiten.\n2 Die Leiter und Tragelemente müssen eine Bruchkraft von mindestens 1,25 kN aufweisen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-17.fr.json","api_md":"/api/v1/ch/lev/art-17.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_17","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-17","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_17","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-17","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-17/fr/","kennung":"ch/lev/art-17","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 17","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"1c8250bb99f92bc49e73fbc1b8c71a3194b1aea453f0acf5187b904cf79c78fa","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-17","titel":"Conducteurs et éléments porteurs de câbles aériens","typ":"stelle","url":"/ch/lev/art-17/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 La contrainte à laquelle sont soumis les conducteurs et les éléments porteurs ne doit pas dépasser la contrainte maximale à la traction du matériau utilisé.\n2 Les conducteurs et les éléments porteurs doivent résister à une charge minimale de rupture de 1,25 kN."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-17.it.json","api_md":"/api/v1/ch/lev/art-17.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_17","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-17","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_17","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-17","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-17/it/","kennung":"ch/lev/art-17","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 17","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"1ef75bba714f18f8e6a89dce74385b200d225b999629f33afecbd398ff5a1505","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-17","titel":"Conduttori ed elementi portanti dei cavi aerei","typ":"stelle","url":"/ch/lev/art-17/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 La sollecitazione a cui sono sottoposti i conduttori e gli elementi portanti non deve superare la massima sollecitazione alla trazione ammissibile per i materiali impiegati.\n2 I conduttori e gli elementi portanti devono avere un carico di rottura almeno pari a 1,25 kN."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-18.de.json","api_md":"/api/v1/ch/lev/art-18.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_18","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-18","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_18","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-18","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-18/de/","kennung":"ch/lev/art-18","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 18","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"af421a1ff3e07da3a0596c9686b21eb015313077f8ce24774c1df904477803ef","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-18","titel":"Grösster Leiterzug","typ":"stelle","url":"/ch/lev/art-18/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Die maximal zu erwartende Zugbeanspruchung eines Leiters oder Kabels ist aufgrund folgender Annahmen zu berechnen:\na. einer Leitertemperatur von –20 °C ohne Zusatzlast;\nb. einer Leitertemperatur von 0 °C und einer gleichmässig verteilten Zusatzlast von mindestens 8 N/m, ohne Wind.\n2 Sind aufgrund der örtlichen Verhältnisse tiefere Temperaturen oder grössere Zusatzlasten zu erwarten, so sind diese der Berechnung zugrunde zu legen.\n3 Bei Luftkabeln gelten die Temperaturannahmen immer für das Tragelement. Das Kabelgewicht bzw. die nicht als Tragelement dienenden Leiter sind zur Zusatzlast zu addieren."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-18.fr.json","api_md":"/api/v1/ch/lev/art-18.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_18","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-18","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_18","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-18","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-18/fr/","kennung":"ch/lev/art-18","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 18","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"5fc892d1f2678f3b75f3389dffa3b8bd4c595b4b9c56f61caa0870ac1aaeb776","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-18","titel":"Contrainte maximale à la traction des conducteurs","typ":"stelle","url":"/ch/lev/art-18/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 La contrainte maximale à la traction d’un conducteur ou d’un câble se calcule à partir des hypothèses suivantes:\na. une température du conducteur de –20° C, sans surcharge;\nb. une température du conducteur de 0° C et une surcharge uniformément répartie d’au moins 8N/m sans vent.\n2 Si les conditions locales montrent que des températures plus basses ou des surcharges plus fortes sont à prévoir, on les introduira dans le calcul.\n3 Pour les câbles aériens, les hypothèses de température sont toujours valables pour l’élément porteur. Le poids du câble ou des conducteurs qui ne tiennent pas lieu d’élément porteur est à ajouter à la surcharge."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-18.it.json","api_md":"/api/v1/ch/lev/art-18.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_18","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-18","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_18","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-18","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-18/it/","kennung":"ch/lev/art-18","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 18","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"d40633d5073d4fd387bc0bab30981da1271cd18352287f7f50a158bb1eb54b44","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-18","titel":"Sollecitazione massima alla trazione","typ":"stelle","url":"/ch/lev/art-18/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Per il calcolo della sollecitazione massima alla trazione a cui sarà presumibilmente sottoposto un conduttore o un cavo, si assumono le seguenti ipotesi:\na. una temperatura del conduttore pari a –20° C, senza sovraccarico;\nb. una temperatura del conduttore pari a 0° C ed un sovraccarico distribuito uniformemente pari ad almeno 8 N/m, in assenza di vento.\n2 Se, in base alle esperienze raccolte in loco, bisogna attendersi temperature più basse o sovraccarichi maggiori, saranno queste ultime condizioni ad essere assunte quali ipotesi di calcolo.\n3 Per i cavi aerei, le ipotesi relative alle temperature si riferiscono sempre agli elementi portanti. Il peso del cavo o i conduttori che non servono da elemento portante devono essere aggiunti al sovraccarico."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-19.de.json","api_md":"/api/v1/ch/lev/art-19.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_19","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-19","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_19","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-19","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-19/de/","kennung":"ch/lev/art-19","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 19","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"0e7444b4e8391632eba66081a4f5f27f3d577a19df7b5274eba08d4a305e14fa","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-19","titel":"Grösster Leiterdurchhang","typ":"stelle","url":"/ch/lev/art-19/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Der maximal zu erwartende Durchhang eines Leiters oder Kabels ist aufgrund folgender Annahmen zu berechnen:\na. einer Leitertemperatur von 40 °C;\nb. einer Leitertemperatur von 0 °C und einer gleichmässig verteilten Zusatzlast von mindestens 8 N/m ohne Wind.\n2 Sind aufgrund der örtlichen Verhältnisse höhere Temperaturen oder grössere Zusatzlasten zu erwarten, so sind diese der Berechnung zugrunde zu legen.\n3 Bei Luftkabeln gelten die Temperaturannahmen immer für das Tragelement. Das Kabelgewicht bzw. die nicht als Tragelement dienenden Leiter sind zur Zusatzlast zu addieren."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-19.fr.json","api_md":"/api/v1/ch/lev/art-19.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_19","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-19","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_19","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-19","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-19/fr/","kennung":"ch/lev/art-19","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 19","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"4b962230555459e22162f0eb08bbe3f3b562b02f876d43d2eb5b26f91cec9602","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-19","titel":"Flèche maximale des conducteurs","typ":"stelle","url":"/ch/lev/art-19/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 La flèche maximale d’un conducteur ou d’un câble se calcule à partir des hypothèses suivantes:\na. une température du conducteur de 40° C;\nb. une température du conducteur de 0° C et une surcharge uniformément répartie d’au moins 8 N/m sans vent.\n2 Si les conditions locales montrent que des températures plus élevées ou des surcharges plus fortes sont à prévoir, on les introduira dans le calcul.\n3 Pour les câbles aériens, les hypothèses de température sont toujours valables pour l’élément porteur. Le poids du câble ou des conducteurs qui ne tiennent pas lieu d’élément porteur est à ajouter à la surcharge."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-19.it.json","api_md":"/api/v1/ch/lev/art-19.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_19","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-19","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_19","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-19","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-19/it/","kennung":"ch/lev/art-19","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 19","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"be399121cdad6e416f8bad9fc887d6666bc2e5fe00a1fd51fb1e85eb0bdf1666","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-19","titel":"Freccia massima dei conduttori","typ":"stelle","url":"/ch/lev/art-19/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Per il calcolo della freccia massima presumibile di un conduttore o di un cavo, si assumono le seguenti ipotesi:\na. una temperatura del conduttore pari a +40° C;\nb. una temperatura del conduttore pari a 0° C ed un sovraccarico distribuito uniformemente pari ad almeno 8 N/m, in assenza di vento.\n2 Se, in base alle esperienze raccolte in loco, bisogna attendersi temperature più basse o sovraccarichi maggiori, saranno queste ultime condizioni ad essere assunte quali ipotesi di calcolo.\n3 Per i cavi aerei, le ipotesi relative alle temperature si riferiscono sempre agli elementi portanti. Il peso del cavo o i conduttori che non servono da elemento portante devono essere aggiunti al sovraccarico."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-20.de.json","api_md":"/api/v1/ch/lev/art-20.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_20","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-20","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_20","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-20","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-20/de/","kennung":"ch/lev/art-20","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 20","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"54f3f4f20defac78594b4c5d0d146363d9d19edaf9522fcb54178acb7d9bd16b","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-20","titel":"Leiterverbindungen","typ":"stelle","url":"/ch/lev/art-20/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Die Verbindungen der Leiter müssen denselben elektrotechnischen Anforderungen genügen wie das Leitermaterial.\n2 Die Verbindungen von selbsttragenden Leitern oder von Tragelementen von Luftkabeln müssen die Anforderungen nach Artikel 17 erfüllen.\n3 Freileitungen dürfen nicht aus mehreren kurzen Leiterstücken zusammengesetzt werden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-20.fr.json","api_md":"/api/v1/ch/lev/art-20.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_20","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-20","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_20","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-20","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-20/fr/","kennung":"ch/lev/art-20","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 20","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"a3e82776c1aa7a6974facf6edc3793dc96bd2cbe0a1978796a7386d6d33ae034","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-20","titel":"Jonctions des conducteurs","typ":"stelle","url":"/ch/lev/art-20/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les manchons de jonction des conducteurs doivent répondre aux mêmes exigences électrotechniques que les conducteurs eux-mêmes.\n2 Les manchons de jonction des conducteurs autoporteurs ou des éléments porteurs de câbles aériens doivent remplir les conditions fixées à l’art. 17.\n3 L’utilisation de courts tronçons de conducteurs assemblés n’est pas admise pour une ligne aérienne."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-20.it.json","api_md":"/api/v1/ch/lev/art-20.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_20","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-20","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_20","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-20","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-20/it/","kennung":"ch/lev/art-20","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 20","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"09b4022dfe38541f570b788be4e6613d42b3a7b6e290ce733122206c6747084b","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-20","titel":"Giunzioni dei conduttori","typ":"stelle","url":"/ch/lev/art-20/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le giunzioni dei conduttori devono soddisfare alle stesse esigenze elettrotecniche del materiale dei conduttori.\n2 Le giunzioni dei conduttori autoportanti o degli elementi portanti dei cavi aerei devono soddisfare le esigenze di cui all’articolo 17.\n3 Le linee aeree non devono essere composte di più spezzoni di conduttori."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-21.de.json","api_md":"/api/v1/ch/lev/art-21.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_21","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-21","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_21","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-21","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-21/de/","kennung":"ch/lev/art-21","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 21","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"29a23c494f48add43dae5e30f7b551ac9782afea11a572572f0b409441bc45aa","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-21","titel":"Isolatoren","typ":"stelle","url":"/ch/lev/art-21/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Die Mindestbruchkraft von Stab‑, Stütz- und Stützenisolatoren aus keramischen Werkstoffen oder aus Glas muss mindestens 2,8 mal grösser sein als die grössten statischen Belastungen.\n2 Verbundisolatoren aus Kunststoff müssen witterungsbeständig und gegen UV-Strahlung resistent sein."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-21.fr.json","api_md":"/api/v1/ch/lev/art-21.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_21","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-21","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_21","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-21","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-21/fr/","kennung":"ch/lev/art-21","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 21","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"2707877805aedd6538d698c5b19ff07bd98985abe7c34d377d8f192d3f61694c","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-21","titel":"Isolateurs","typ":"stelle","url":"/ch/lev/art-21/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 La charge de rupture minimale des isolateurs en céramique ou en verre, qu’ils soient à long fût, supports ou rigides à tige, doit présenter un coefficient de sécurité d’au moins 2,8 par rapport aux charges statiques maximales.\n2 Les isolateurs composites en matière synthétique doivent être résistants aux intempéries et au rayonnement ultraviolet."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-21.it.json","api_md":"/api/v1/ch/lev/art-21.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_21","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-21","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_21","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-21","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-21/it/","kennung":"ch/lev/art-21","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 21","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"6ec1e26052d7b2e7bf98bfb4b0d9ca7efc9372ff60e538302651eaeb20f71313","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-21","titel":"Isolatori","typ":"stelle","url":"/ch/lev/art-21/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Il carico di rottura minimo degli isolatori a bastone, degli isolatori rigidi a perno e degli isolatori rigidi a base, di materiali ceramici o di vetro, deve essere almeno pari a 2,8 volte la sollecitazione statica massima.\n2 Gli isolatori compositi di materiale sintetico devono resistere alle intemperie ed all’azione dei raggi ultravioletti."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-22.de.json","api_md":"/api/v1/ch/lev/art-22.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_22","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-22","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_22","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-22","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-22/de/","kennung":"ch/lev/art-22","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 22","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"6ae36930da90e6450d0426d22e1c1cc3220702b6bfb927c27a708b951e3b2cb3","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-22","titel":"Befestigungselemente","typ":"stelle","url":"/ch/lev/art-22/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Die Leiter- und Tragelementbefestigungen müssen den Tragwerkarten entsprechen und die auf sie wirkenden Belastungen sicher übertragen können."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-22.fr.json","api_md":"/api/v1/ch/lev/art-22.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_22","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-22","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_22","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-22","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-22/fr/","kennung":"ch/lev/art-22","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 22","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"4efe6e56696fc812bf876d449677ffb124b82a5de889a07d807f0ed21f76d9c6","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-22","titel":"Éléments de fixation","typ":"stelle","url":"/ch/lev/art-22/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les fixations du conducteur et de l’élément porteur doivent correspondre au type de support et résister avec sûreté aux charges engendrées."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-22.it.json","api_md":"/api/v1/ch/lev/art-22.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_22","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-22","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_22","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-22","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-22/it/","kennung":"ch/lev/art-22","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 22","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"3a3cf880dd8c32afdc2c97fbb93a88f0e815b8a16f5ffb70a830d3cf931c2902","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-22","titel":"Elementi di fissaggio","typ":"stelle","url":"/ch/lev/art-22/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"I fissaggi dei conduttori e degli elementi portanti devono essere adatti ai tipi di sostegni e devono poter trasmettere con sicurezza i carichi a cui sono sottoposti."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-23.de.json","api_md":"/api/v1/ch/lev/art-23.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_23","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-23","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_23","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-23","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-23/de/","kennung":"ch/lev/art-23","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 23","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"1396ab3b777e7a2be0af317c021a3108539d89245e513b23077f9d707270a98d","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-23","titel":"Materialbeständigkeit","typ":"stelle","url":"/ch/lev/art-23/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Leiter, Luftkabel, Leiterverbindungen, Isolatoren und Armaturen müssen gegen äussere Einflüsse und elektrochemische Zersetzung beständig sein."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-23.fr.json","api_md":"/api/v1/ch/lev/art-23.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_23","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-23","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_23","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-23","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-23/fr/","kennung":"ch/lev/art-23","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 23","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"b02e790e46c5bb668515c7c9282e7a39c141b378b76496730b6ff625a85102f3","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-23","titel":"Compatibilité du matériel","typ":"stelle","url":"/ch/lev/art-23/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les conducteurs, les câbles aériens, les manchons de jonction des conducteurs, les isolateurs et les armatures doivent résister aux conditions environnantes ainsi qu’à la désagrégation électrochimique."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-23.it.json","api_md":"/api/v1/ch/lev/art-23.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_23","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-23","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_23","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-23","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-23/it/","kennung":"ch/lev/art-23","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 23","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"611dd5b459c1a061bd18c2efd1c6f0cbaa9704f7d311b342f5f86d9371d6fb3b","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-23","titel":"Resistenza dei materiali","typ":"stelle","url":"/ch/lev/art-23/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"I conduttori, i cavi aerei, le giunzioni dei conduttori, gli isolatori e le morsetterie devono resistere agli influssi esterni e agli attacchi di natura elettrochimica."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-24.de.json","api_md":"/api/v1/ch/lev/art-24.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_24","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-24","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_24","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-24","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-24/de/","kennung":"ch/lev/art-24","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 24","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"ec3cc6a5729f0dd27b7f5cf66121e2aaf23232ed2b46cc399e51676a72f1dc02","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-24","titel":"Tragfähigkeit und Standfestigkeit von Tragwerken, Fundamenten, Verstrebungen und Verankerungen","typ":"stelle","url":"/ch/lev/art-24/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Tragwerke, Fundamente, Verstrebungen, Verankerungen und deren Bestandteile sind so zu dimensionieren und zu konstruieren, dass sie den grössten Belastungen standhalten.\n2 Als grösste Belastung gilt die ungünstigste Kombination aller Kräfte, die auf ein Tragwerk oder einen Bestandteil davon einwirken können. Zu berücksichtigen sind:\na. die Leiterkräfte bei 0 °C und eine gleichmässig verteilte Zusatzlast von mindestens 8 N/m pro Leiter oder Luftkabel;\nb. die horizontalen Windkräfte.\n3 Als Werkstoffe sind für Tragwerke Stahl, Stahlbeton oder Holz zu verwenden. Tragwerke aus solchen Werkstoffen sind nach Anhang 4 zu dimensionieren.\n4 Andere Werkstoffe oder unübliche Konstruktionen dürfen nur verwendet werden, wenn ihre Eignung, insbesondere hinsichtlich Festigkeit und Dauerhaftigkeit, nachgewiesen wird. Die Kontrollstelle kann Prüfatteste von anerkannten Prüfstellen oder besondere Prüfungen verlangen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-24.fr.json","api_md":"/api/v1/ch/lev/art-24.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_24","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-24","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_24","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-24","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-24/fr/","kennung":"ch/lev/art-24","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 24","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"161e6d3835c82b0128c5d66b4f8354d39e87326bdf22e6d7d5918550969fbc65","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-24","titel":"Résistance et stabilité des supports, des fondations, des contrefiches et des haubans","typ":"stelle","url":"/ch/lev/art-24/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les supports, les fondations, les contrefiches, les haubans et leurs éléments constitutifs doivent être dimensionnés et construits de façon à résister aux charges maximales.\n2 La charge maximale est déterminée par la combinaison la plus défavorable de tous les efforts qui agissent sur un support ou sur un de ses éléments. Il faut considérer:\na. les efforts dus aux conducteurs à 0° C et une surcharge uniformément répartie d’au moins 8 N/m par conducteur ou câble aérien;\nb. la pression horizontale du vent.\n3 Les matériaux généralement utilisés pour les supports sont l’acier, le béton armé ou le bois. Les supports utilisant ces matériaux sont à dimensionner conformément à l’annexe 4.\n4 D’autres matériaux ou des constructions non usuelles ne peuvent être employés que si leur aptitude, en particulier leur résistance mécanique et leur durabilité, est prouvée. L’organe de contrôle peut exiger un certificat d’essais d’une station d’essais reconnue ou ordonner l’exécution d’essais particuliers."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-24.it.json","api_md":"/api/v1/ch/lev/art-24.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_24","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-24","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_24","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-24","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-24/it/","kennung":"ch/lev/art-24","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 24","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"30842707bc0b8df700bbe73dc43e81e89e0ac2f4ef8819b81021286dc61ec966","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-24","titel":"Solidità e stabilità di sostegni, fondazioni, contropali e tiranti e ancoraggi","typ":"stelle","url":"/ch/lev/art-24/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 I sostegni, le fondazioni, i contropali e tiranti, gli ancoraggi ed i loro componenti devono essere dimensionati e costruiti in modo da resistere alle massime sollecitazioni.\n2 Per sollecitazione massima si intende la combinazione più sfavorevole di tutte le forze che possono agire su un sostegno o parti dello stesso. Si devono prendere in considerazione:\na. le forze esercitate dai conduttori alla temperatura di 0° C e con un sovraccarico ripartito uniformemente pari ad almeno 8 N/m per ogni conduttore o cavo aereo;\nb. le spinte orizzontali del vento.\n3 Come materiali per i sostegni si impiegano generalmente acciaio, cemento armato o legno. I sostegni costituiti dai suddetti materiali devono essere dimensionati conformemente all’appendice 4.\n4 Altri materiali o tipi di costruzione inabituali possono essere impiegati soltanto se ne è dimostrata l’idoneità, particolarmente per quanto concerne la resistenza e la durata. L’organo di controllo può esigere attestati di prova rilasciati da laboratori di prova riconosciuti oppure l’esecuzione di prove speciali."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-25.de.json","api_md":"/api/v1/ch/lev/art-25.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_25","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-25","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_25","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-25","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-25/de/","kennung":"ch/lev/art-25","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 25","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"1519e0873e717bbb284e42f14cd9013ca22ba2536a8243b0bdab94357290a893","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-25","titel":"Tragwerkfundamente","typ":"stelle","url":"/ch/lev/art-25/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Holzmaste müssen mindestens mit einem Zehntel ihrer Länge plus 40 cm ins Erdreich eingelassen werden.\n2 Sie sind fest zu verrammen. Wenn es Belastung und Bodenbeschaffenheit erfordern, ist die Druckfläche zu vergrössern.\n3 Holzmaste, die in den Boden einbetoniert werden, sind spätestens nach drei Jahren wieder zu entfernen.\n4 Als besondere Fundamente dürfen nur Stangenfüsse aus Material verwendet werden, das gegen die Einwirkungen des Erdbodens widerstandsfähig ist. Die Holzmasten müssen auswechselbar und vor Erdfeuchtigkeit und Wasseransammlung geschützt befestigt werden. Die Festigkeit der Stangenfüsse muss wenigstens gleich gross sein wie die der Tragwerke.\n5 Fundamente für Tragwerke, die nicht aus Holz sind, sind für die grössten zu erwartenden Belastungen unter Berücksichtigung der Fundamenteinspannung zu berechnen. Die Sicherheit gegen Umsturz muss mindestens 1,5 sein."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-25.fr.json","api_md":"/api/v1/ch/lev/art-25.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_25","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-25","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_25","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-25","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-25/fr/","kennung":"ch/lev/art-25","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 25","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"62de9235b06a746f39f32e70bba399db566fc6e89ea879df17b3ed451fc6e83c","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-25","titel":"Fondations des supports","typ":"stelle","url":"/ch/lev/art-25/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 La profondeur d’implantation dans le sol des poteaux en bois doit être au minimum égale au dixième de leur longueur plus 40 cm.\n2 Les poteaux en bois doivent être calés solidement. Suivant la charge et la nature du terrain, on augmentera la surface d’appui.\n3 Les poteaux en bois encastrés dans des massifs en béton doivent être démontés au plus tard trois ans après.\n4 Lorsqu’on utilise des fondations spéciales, seuls des socles formés de matériaux résistants à l’action du sol peuvent être employés. Les poteaux doivent y être fixés de façon à pouvoir être remplacés aisément tout en étant protégés contre l’humidité et la stagnation d’eau de pluie. Les socles doivent présenter une résistance au moins égale à celle des poteaux eux-mêmes.\n5 Les fondations des supports en matériaux autres que le bois doivent être calculées pour la charge maximale prévisible en tenant compte de l’encastrement. Le coefficient de sécurité au renversement doit être d’au minimum 1,5."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-25.it.json","api_md":"/api/v1/ch/lev/art-25.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_25","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-25","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_25","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-25","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-25/it/","kennung":"ch/lev/art-25","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 25","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"1f5722826772fff8e186b128a07324696dbd66e5dfa6bcb7ed2d67024e2cad1e","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-25","titel":"Fondazioni dei sostegni","typ":"stelle","url":"/ch/lev/art-25/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 I pali di legno devono essere infissi nel terreno per una profondità pari ad almeno un decimo della loro lunghezza più 40 cm.\n2 Essi devono essere solidamente rincalzati. Se le sollecitazioni e le caratteristiche del terreno lo esigono, si deve aumentare la superficie di pressione.\n3 I pali di legno cementati direttamente nel terreno vanno rimossi dopo un periodo di tempo non superiore a tre anni.\n4 Come fondazioni speciali possono essere impiegati soltanto zoccoli resistenti all’azione del terreno. I pali di legno devono poter essere sostituiti e vanno fissati in modo da risultare protetti dall’umidità del terreno e dal ristagno di acqua. La resistenza degli zoccoli deve essere almeno uguale a quella dei sostegni.\n5 Le fondazioni dei sostegni costituiti da materiali diversi dal legno devono essere dimensionate per le sollecitazioni massime presumibili, tenendo conto delle reazioni di incastro. La sicurezza al rovesciamento deve essere almeno pari a 1,5."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-26.de.json","api_md":"/api/v1/ch/lev/art-26.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_26","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-26","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_26","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-26","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-26/de/","kennung":"ch/lev/art-26","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 26","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"96dba92ccc249034500d6c2eb0972f5f1bf2f34284ad7bd0cf1eb4c6a688f1ee","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-26","titel":"Verankerungen","typ":"stelle","url":"/ch/lev/art-26/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Stahldrahtseile von Verankerungen müssen einen Mindestquerschnitt von 20 mm2 aufweisen. Im Erdboden ist für Rundstahl ein Mindestdurchmesser von 10 mm, bei Stahldrahtseilen ein Mindestquerschnitt von 70 mm2 erforderlich.\n2 Verankerungen müssen jederzeit nachgespannt werden können.\n3 Verankerungen aus elektrisch leitendem Material sind so an den Tragwerken zu befestigen, dass Berührungen mit unter Spannung stehenden Anlageteilen ausgeschlossen sind."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-26.fr.json","api_md":"/api/v1/ch/lev/art-26.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_26","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-26","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_26","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-26","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-26/fr/","kennung":"ch/lev/art-26","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 26","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"d150749b4331082fa70aad2995cbb1bad5e397a92b5288670a218fe66d365a54","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-26","titel":"Haubans","typ":"stelle","url":"/ch/lev/art-26/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 La section des câbles en acier des haubans doit être d’au moins 20 mm2. Dans le sol, une tringle d’acier rond doit avoir un diamètre d’au moins 10 mm; un câble d’acier, une section d’au moins 70 mm2.\n2 Les haubans doivent être munis de tendeurs afin de permettre en tout temps un réglage ultérieur.\n3 Les haubans électriquement conducteurs doivent être fixés aux supports de façon à exclure tout contact avec des parties d’installations sous tension."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-26.it.json","api_md":"/api/v1/ch/lev/art-26.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_26","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-26","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_26","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-26","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-26/it/","kennung":"ch/lev/art-26","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 26","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"49f629c6ae8cf988788c0a52d3435cc23122997ffebf02864b50ee37bb081ad2","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-26","titel":"Ancoraggi (tiranti)","typ":"stelle","url":"/ch/lev/art-26/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 La fune metallica usata per gli ancoraggi deve avere una sezione di almeno 20 mm2. Nel terreno, i tondini di acciaio devono avere un diametro minimo di 10 mm, le funi di acciaio una sezione minima di 70 mm2.\n2 Gli ancoraggi devono poter essere tesi ulteriormente in qualsiasi momento.\n3 Gli ancoraggi di materiale elettricamente conduttore devono essere fissati al sostegno in modo da escludere il contatto con parti dell’impianto sotto tensione."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-27.de.json","api_md":"/api/v1/ch/lev/art-27.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_27","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-27","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_27","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-27","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-27/de/","kennung":"ch/lev/art-27","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 27","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"b896d780b36e22814f132b7b7ad222b47bbab8f82a6ed715470e748462ccb272","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-27","titel":"Schutz der Tragwerke","typ":"stelle","url":"/ch/lev/art-27/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Tragwerke, Fundamente, Verstrebungen und Verankerungen müssen gegen äussere Einflüsse so geschützt werden, dass Standfestigkeit und Tragfähigkeit dauernd gewährleistet sind.\n2 Tragwerke und Tragwerkteile aus Holz müssen imprägniert oder auf gleichwertige Weise geschützt sein.\n3 Schnittstellen bei Holztragwerken sind so abzudecken oder so anzuordnen, dass sich kein Wasser ansammeln kann."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-27.fr.json","api_md":"/api/v1/ch/lev/art-27.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_27","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-27","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_27","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-27","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-27/fr/","kennung":"ch/lev/art-27","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 27","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"bb277377d8a649452593b05de3c820d715b96bbd1bfa020ade7dc8504fc24692","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-27","titel":"Protection des supports","typ":"stelle","url":"/ch/lev/art-27/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les supports, les fondations, les contrefiches et les haubans doivent être protégés contre les influences extérieures, afin que soient garanties en permanence leur stabilité et leur résistance.\n2 Les supports et les parties de supports en bois doivent être imprégnés ou protégés de façon similaire.\n3 Les points de jonction des supports en bois doivent être couverts ou disposés de façon à exclure la stagnation d’eau."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-27.it.json","api_md":"/api/v1/ch/lev/art-27.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_27","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-27","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_27","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-27","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-27/it/","kennung":"ch/lev/art-27","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 27","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"ecb7fecc8e09a9752a1f3c0581a1f2844da4a93a314d1d305df292e8bdd1b547","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-27","titel":"Protezione dei sostegni","typ":"stelle","url":"/ch/lev/art-27/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 I sostegni, le fondazioni, i contropali e tiranti e gli ancoraggi devono essere protetti dagli influssi esterni in modo tale da garantire in ogni momento la loro stabilità e solidità.\n2 I sostegni di legno ed i componenti di legno dei sostegni devono essere impregnati o protetti in modo equivalente.\n3 I giunti dei sostegni di legno devono essere disposti o protetti in modo da evitare i ristagni d’acqua."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-28.de.json","api_md":"/api/v1/ch/lev/art-28.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_28","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-28","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_28","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-28","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-28/de/","kennung":"ch/lev/art-28","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 28","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"fd98a87cbe7bf273d8b08ebcecf43a02c8407278ada3a2432e9a37020dc18b71","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-28","titel":"Kennzeichnung der Tragwerke","typ":"stelle","url":"/ch/lev/art-28/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Tragwerke müssen die Initialen des Leitungsinhabers tragen sowie mit einer Ordnungsnummer und mit der Jahreszahl der Aufstellung versehen sein (Hinweistafel).\n2 Holzmasten sind 4,5 m über dem Fussende mit der Jahreszahl der Imprägnierung und dem Kennzeichen des Lieferanten dauerhaft zu markieren."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-28.fr.json","api_md":"/api/v1/ch/lev/art-28.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_28","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-28","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_28","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-28","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-28/fr/","kennung":"ch/lev/art-28","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 28","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"4422a19fe0fa6360bd143680a536bba7a1fb21b4d5f897bb489c283128d3b6ea","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-28","titel":"Indications figurant sur les supports","typ":"stelle","url":"/ch/lev/art-28/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les supports doivent être munis d’une plaquette indicatrice mentionnant un numéro d’ordre, l’année de la pose et les initiales du propriétaire de la ligne.\n2 Les poteaux en bois doivent en outre porter à 4,5 m au-dessus du pied, en caractères indélébiles, l’année de l’imprégnation et l’identification du fournisseur."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-28.it.json","api_md":"/api/v1/ch/lev/art-28.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_28","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-28","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_28","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_1","num":"1. Abschnitt:","titel":"Schwachstromfreileitungen"}],"id":"ch/lev/art-28","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-28/it/","kennung":"ch/lev/art-28","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 28","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"b55be848e868ad6b9f0873c10c1f0cf0cdee78fe1bb64ae7bf024b5c4a983921","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-28","titel":"Identificazione dei sostegni","typ":"stelle","url":"/ch/lev/art-28/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 I sostegni devono essere provvisti di un numero d’ordine, dell’anno di costruzione e delle iniziali dell’esercente della linea (targa indicatrice).\n2 Sui sostegni di legno vanno inoltre marcati indelebilmente, ad una altezza di 4,5 m dal piede, l’anno di impregnazione e la designazione del fornitore."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-29.de.json","api_md":"/api/v1/ch/lev/art-29.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_29","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-29","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_29","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-29","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-29/de/","kennung":"ch/lev/art-29","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 29","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"7b67cdc3cbb15d2b4c0cfb9c326f88909529e2a34b3df1ff789bf337585a2d71","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-29","titel":"Störschutz","typ":"stelle","url":"/ch/lev/art-29/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Für Hochspannungsleitungen und deren Konstruktionselemente gelten die Störschutzwerte nach Anhang 5."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-29.fr.json","api_md":"/api/v1/ch/lev/art-29.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_29","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-29","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_29","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-29","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-29/fr/","kennung":"ch/lev/art-29","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 29","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"b0e3f7a3fb142eac033b3cb28a460efd0204384a88b8c625d85f11d2ce3725ff","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-29","titel":"Protection antiparasite","typ":"stelle","url":"/ch/lev/art-29/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Le pouvoir perturbateur des lignes à haute tension et de leurs éléments de construction ne doit pas dépasser les valeurs indiquées à l’annexe 5."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-29.it.json","api_md":"/api/v1/ch/lev/art-29.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_29","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-29","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_29","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-29","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-29/it/","kennung":"ch/lev/art-29","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 29","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"72c9541b7cfe94eba132cac4f13523527e59c50f894fbeff48e88458aa57111d","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-29","titel":"Protezione contro le perturbazioni","typ":"stelle","url":"/ch/lev/art-29/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Per le linee ad alta tensione ed i loro elementi costruttivi valgono i valori di protezione riportati nell’appendice 5."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-30.de.json","api_md":"/api/v1/ch/lev/art-30.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_30","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-30","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_30","fussnoten":[{"marker":"27","nummer":27,"text":"Fassung gemäss Ziff. I der V vom 25. Juni 2025, in Kraft seit 1. Aug. 2025 (AS 2025 451)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-30","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-30/de/","kennung":"ch/lev/art-30","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 30","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"350ce3cf3db32d967c40f35a7f349ec8cc4b924017788193b317fc5e67375428","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-30","titel":"Vogelschutz","typ":"stelle","url":"/ch/lev/art-30/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Neue Leitungen sind so auszuführen, dass das Kollisionsrisiko für Vögel möglichst gering ist. Tragwerke sind so auszugestalten, dass Vögel auf diesen keine Erd- und Kurzschlüsse einleiten können.\n2 An bestehenden Tragwerken von Leitungen mit einer Spannung von 1 bis 150 kV, die für Vögel aufgrund ihrer Bauweise eine Gefährdung darstellen, sind Vorkehren zu treffen, damit Vögel auf diesen möglichst keine Erd- und Kurzschlüsse einleiten können."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-30.fr.json","api_md":"/api/v1/ch/lev/art-30.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_30","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-30","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_30","fussnoten":[{"marker":"26","nummer":26,"text":"Nouvelle teneur selon le ch. I de l’O du 25 juin 2025, en vigueur depuis le 1er août 2025 (RO 2025 451)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-30","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-30/fr/","kennung":"ch/lev/art-30","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 30","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"9d322c5222cf822272072dcdf219df02975503159decdfea214921d41aec6763","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-30","titel":"Protection des oiseaux","typ":"stelle","url":"/ch/lev/art-30/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les nouvelles lignes doivent être planifiées et construites de façon à réduire le plus possible le risque de collision pour les oiseaux. Les supports doivent être conçus de sorte que les oiseaux ne puissent pas provoquer de court-circuit à la terre ou entre phases.\n2 Des mesures doivent être prises sur les supports existants des lignes d’une tension de 1 à 150 kV dont la configuration représente un danger pour les oiseaux, afin que ceux-ci ne puissent pas, dans la mesure du possible, y provoquer de court-circuit à la terre ou entre phases."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-30.it.json","api_md":"/api/v1/ch/lev/art-30.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_30","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-30","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_30","fussnoten":[{"marker":"28","nummer":28,"text":"Nuovo testo giusta la cifra I dell’O del 25 giu. 2025, in vigore dal 1° ago. 2025 (RU 2025 451)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-30","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-30/it/","kennung":"ch/lev/art-30","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 30","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"e38cf2b3e9cc16fbc1e3c428f129670ad2cb6c476d86c5ed714038daae01ac27","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-30","titel":"Protezione dei volatili","typ":"stelle","url":"/ch/lev/art-30/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le nuove linee devono essere costruite in modo da ridurre al minimo il rischio di collisione per gli uccelli. I sostegni devono essere concepiti in modo che gli uccelli non possano provocare su di essi messe a terra o cortocircuiti.\n2 Sui sostegni esistenti di linee con una tensione da 1 a 150 kV che, per il modo in cui sono costruiti, rappresentano un pericolo per gli uccelli, devono essere adottate misure affinché, per quanto possibile, i volatili non possano provocare su di essi messe a terra o cortocircuiti."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-31.de.json","api_md":"/api/v1/ch/lev/art-31.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_31","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-31","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_31","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-31","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-31/de/","kennung":"ch/lev/art-31","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 31","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"41ca11c0118c988dbb663a11cd879860ff84d3d4e280820f5336265d621d2b6d","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-31","titel":"Verhaltenshinweise","typ":"stelle","url":"/ch/lev/art-31/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Die Betriebsinhaber von Freileitungen der lokalen oder regionalen Stromversorgung müssen die Bevölkerung in ortsüblicher Art über das Verhalten orientieren:\na. bei gefahrbringenden Tätigkeiten in der Nähe von Freileitungen;\nb. gegenüber defekten Freileitungen, insbesondere gegenüber herabgefallenen Leitern;\nc. gegenüber Personen, die durch elektrischen Strom verletzt worden sind und sich noch im Gefahrenbereich befinden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-31.fr.json","api_md":"/api/v1/ch/lev/art-31.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_31","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-31","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_31","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-31","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-31/fr/","kennung":"ch/lev/art-31","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 31","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"56939c8a5ea3e22ddda42e149d126feb1209a36e9f96d1ccbc26f2fed9855287","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-31","titel":"Indications sur le comportement à adopter","typ":"stelle","url":"/ch/lev/art-31/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les exploitants de lignes aériennes pour la distribution locale ou régionale d’énergie doivent, en se conformant aux usages locaux, informer la population sur le comportement à adopter:\na. lors d’activités, sources de danger, à proximité de lignes aériennes;\nb. en présence de lignes aériennes défectueuses, tout particulièrement lorsqu’un conducteur est tombé à terre;\nc. envers les personnes blessés par le courant électrique et se trouvant encore dans la zone dangereuse."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-31.it.json","api_md":"/api/v1/ch/lev/art-31.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_31","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-31","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_31","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-31","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-31/it/","kennung":"ch/lev/art-31","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 31","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"29a396ec4fddb79e8c9926f06571c03c5f7cad0a85e92276709de2719deefbc8","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-31","titel":"Istruzioni di comportamento","typ":"stelle","url":"/ch/lev/art-31/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Gli esercenti delle linee aeree di distribuzione locale o regionale devono impartire alla popolazione, secondo le consuetudini locali, le istruzioni circa il comportamento da adottare:\na. nell’esercizio di attività che potrebbero rivelarsi pericolose in prossimità delle linee aeree;\nb. in presenza di difetti alle linee aeree, in particolare in presenza di conduttori caduti;\nc. verso le persone ferite dalla corrente elettrica che si trovano ancora nella zona di pericolo."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-32.de.json","api_md":"/api/v1/ch/lev/art-32.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_32","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-32","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_32","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-32","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-32/de/","kennung":"ch/lev/art-32","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 32","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"f2ada085b353d6ceebf86d52b5669ae7a4cdda0c6fd8281cded550f245e652f4","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-32","titel":"Besteigen der Tragwerke","typ":"stelle","url":"/ch/lev/art-32/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Die Tragwerke sind so zu gestalten oder auszurüsten, dass unbefugtes Besteigen nur mit Hilfsmitteln oder mit ausserordentlicher Anstrengung möglich ist."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-32.fr.json","api_md":"/api/v1/ch/lev/art-32.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_32","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-32","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_32","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-32","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-32/fr/","kennung":"ch/lev/art-32","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 32","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"3cdac672659f2136dc08074f2df80ce82cd080e44420b4fe821d4ecb8b9896b3","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-32","titel":"Escalade des supports","typ":"stelle","url":"/ch/lev/art-32/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les supports doivent être conçus ou équipés de sorte qu’il soit impossible d’y grimper sans disposer de moyens auxiliaires ou sans fournir d’efforts extraordinaires."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-32.it.json","api_md":"/api/v1/ch/lev/art-32.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_32","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-32","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_32","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-32","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-32/it/","kennung":"ch/lev/art-32","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 32","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"ceed8a290d340ebc53b29e64e915d1ec4ab9abac2fd652e108783c7307faf4e7","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-32","titel":"Scalata dei sostegni","typ":"stelle","url":"/ch/lev/art-32/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"I sostegni devono essere concepiti o equipaggiati in modo tale che il salirvi abusivamente sia possibile solo con mezzi ausiliari o con sforzi spropositati."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-33.de.json","api_md":"/api/v1/ch/lev/art-33.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_33","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-33","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_33","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-33","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-33/de/","kennung":"ch/lev/art-33","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 33","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"284be7600565be9cdda079781f25c92c4952056871c3a399445a94229ddd1a35","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-33","titel":"Abstand der Leiter unter sich und zu den Tragwerken","typ":"stelle","url":"/ch/lev/art-33/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Der Abstand zwischen spannungsführenden Leitern unter sich und zu Tragwerken ist so zu bemessen, dass in den voraussehbaren Fällen keine Spannungsüberschläge, Spannungsübertritte, Erdschlüsse oder Kurzschlüsse auftreten können.\n2 Die Abstände bestimmen sich aus den jeweils grössten vorhandenen Nennspannungen und den dazugehörenden Prüfspannungen nach Anhang 6. Wo nichts Besonderes bestimmt wird, gelten diese Abstände sowohl für Leiter, Erdleiter und Luftkabel als auch für Schutzseile.\n3 Hochspannungs-Luftkabel ohne geerdete metallene Umhüllung gelten als blanke, unter Spannung stehende Leiter."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-33.fr.json","api_md":"/api/v1/ch/lev/art-33.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_33","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-33","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_33","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-33","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-33/fr/","kennung":"ch/lev/art-33","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 33","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"a9c8acfbf714b0d6546759af11c4b036cba626c964f54925fb4fd596109d290e","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-33","titel":"Distance entre les conducteurs et entre les conducteurs et les supports","typ":"stelle","url":"/ch/lev/art-33/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les distances entre les conducteurs sous tension et entre ces conducteurs et les supports doivent être fixées de façon à éviter, dans les cas prévisibles, tout risque d’arc électrique, de transfert de potentiel et de court-circuit à la terre ou entre phases.\n2 Les distances se calculent en fonction des tensions nominales maximales existantes et des tensions d’essais correspondantes selon l’annexe 6. À défaut d’autre prescription, ces distances sont valables pour les conducteurs, les conducteurs de terre, les câbles aériens et les cordes de protection.\n3 Les câbles aériens à haute tension dépourvus de gaine métallique mise à la terre sont à considérer comme des conducteurs nus sous tension."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-33.it.json","api_md":"/api/v1/ch/lev/art-33.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_33","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-33","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_33","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-33","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-33/it/","kennung":"ch/lev/art-33","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 33","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"93c13e11daf56f12c3315ec069fffa171d68fe3f74855e1404ee66b18e4a3c11","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-33","titel":"Distanze dei conduttori tra loro e dai sostegni","typ":"stelle","url":"/ch/lev/art-33/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le distanze dei conduttori sotto tensione tra loro e dai sostegni devono essere calcolate in modo che, in tutte le situazioni prevedibili, non possano prodursi scariche e sovratensioni pericolose, cortocircuiti alla terra o tra fasi.\n2 Le distanze minime richieste si determinano in base alle massime tensioni nominali presenti e in base alle tensioni di prova ad esse associate secondo l’appendice 6. Se non altrimenti stabilito, queste distanze valgono per i conduttori, i conduttori di terra, i cavi aerei e le funi di guardia.\n3 I cavi aerei ad alta tensione senza involucro metallico messo a terra sono considerati come conduttori nudi sotto tensione."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-34.de.json","api_md":"/api/v1/ch/lev/art-34.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_34","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-34","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_34","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-34","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-34/de/","kennung":"ch/lev/art-34","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 34","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"102f0bb031f93065d40df17b997fe7d67bcd0cd9ef51b9a78e04e0a4be35cfeb","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-34","titel":"Abstand zum Boden","typ":"stelle","url":"/ch/lev/art-34/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Leiter, Luftkabel und Erdleiter müssen sowohl beim grössten Durchhang wie auch bei Windauslenkung mindestens die Bodenabstände nach Anhang 3 aufweisen.\n2 In nicht begehbarem Gebiet, namentlich gegenüber Geländevorsprüngen, muss der minimale Direktabstand bei Windauslenkung 0,01 m pro kV Nennspannung, mindestens jedoch 1,50 m betragen.\n3 Bei im Winter benutzbaren Transportwegen, bei markierten Skipisten und bei viel begangenen Wanderwegen sind auch die mittleren Schneehöhen zu berücksichtigen.\n4 Die Kontrollstelle kann in begründeten Ausnahmefällen kleinere Abstände bewilligen. Sie bestimmt dabei die zu treffenden Schutzmassnahmen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-34.fr.json","api_md":"/api/v1/ch/lev/art-34.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_34","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-34","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_34","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-34","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-34/fr/","kennung":"ch/lev/art-34","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 34","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"06db673e639553495a0105f1c1e3fe0a34bb20ee4e5734752279c9e7ed0f1f15","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-34","titel":"Distance entre les lignes et le sol","typ":"stelle","url":"/ch/lev/art-34/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les distances minimales entre les conducteurs, les câbles aériens, les conducteurs de terre et le sol, aussi bien pour la flèche maximale que pour la déviation due au vent, sont données à l’annexe 3.\n2 Dans les régions impraticables, notamment par rapport aux éperons ou à d’autres saillies de terrain, la distance directe minimale en cas de déviations dues au vent doit être égale à 0,01 m par kV de tension nominale, mais jamais inférieure à 1,50 m.\n3 On tiendra compte des hauteurs moyennes de la neige pour les pistes de ski, les chemins carrossables en hiver et les chemins touristiques très fréquentés.\n4 Dans certains cas exceptionnels justifiés, l’organe de contrôle peut autoriser des distances inférieures. Il fixe alors les mesures de protection adéquates."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-34.it.json","api_md":"/api/v1/ch/lev/art-34.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_34","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-34","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_34","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-34","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-34/it/","kennung":"ch/lev/art-34","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 34","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"2d014eaf29682fc4c3c98bb29106385556127539b144e92197a31c067abab6fd","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-34","titel":"Distanza dal suolo","typ":"stelle","url":"/ch/lev/art-34/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Sia in presenza della freccia massima sia in presenza di oscillazioni impresse dal vento, conduttori, cavi aerei e conduttori di terra devono avere almeno le distanze minime dal suolo indicate nell’appendice 3.\n2 Nelle zone non accessibili, specialmente per quanto concerne le sporgenze del terreno, la distanza diretta minima in presenza di oscillazione impressa dal vento ammonta a 0,01 m per ogni kV di tensione nominale, ma in ogni caso non inferiore a 1,5 m.\n3 In presenza di percorsi usati in inverno per i trasporti, di piste sciistiche contrassegnate e di sentieri molto frequentati, occorre tener conto anche dell’altezza media della coltre nevosa.\n4 In casi eccezionali motivati, l’autorità di controllo può autorizzare distanze più piccole. In tal caso, essa definisce le misure protettive da adottare."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-35.de.json","api_md":"/api/v1/ch/lev/art-35.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_35","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-35","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_35","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-35","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-35/de/","kennung":"ch/lev/art-35","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 35","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"99d52309c9f7da633325958801781edc391f571ed5ba294756d67e3dd0d1209c","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-35","titel":"Abstand zu Bäumen","typ":"stelle","url":"/ch/lev/art-35/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Die Direktabstände zwischen elektrischen Leitern und Bäumen richten sich nach Bewirtschaftung der Bäume, Bodenbeschaffenheit, Geländeneigung, Schneeabfall von den Bäumen usw.\n2 Der Abstand zu Obst- und Zierbäumen unter oder neben Leitungen ist so zu bemessen, dass die Bäume gefahrlos bewirtschaftet werden können.\n3 Für Baum- und Pflanzenspritzanlagen sind die Spritzabstände zu den Leitern der Freileitungen und allfällige Schutzvorkehren von Fall zu Fall festzulegen.\n4 Die Vertikalabstände zwischen Bäumen und blanken Leitern von Hochspannungsfreileitungen müssen bei grösstem Durchhang mindestens betragen:\na. Obstbäume: 2,5 m plus 0,01 m pro kV Nennspannung;\nb. übrige Bäume: 1,5 m plus 0,01 m pro kV Nennspannung."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-35.fr.json","api_md":"/api/v1/ch/lev/art-35.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_35","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-35","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_35","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-35","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-35/fr/","kennung":"ch/lev/art-35","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 35","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"b574e1105fc565381639a4cf39852c73f515cd1bc83368c9dee3b43cfc8a6160","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-35","titel":"Distance entre les lignes et les arbres","typ":"stelle","url":"/ch/lev/art-35/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les distances directes entre les conducteurs des lignes aériennes et les arbres sont fonction de l’exploitation des arbres, de la nature du sol et de son inclinaison, de la neige accumulée sur les arbres, etc.\n2 Les distances entre les conducteurs des lignes aériennes et les arbres fruitiers ou les arbres d’ornement doivent permettre d’exploiter les arbres sans danger.\n3 Pour les installations d’arrosage d’arbres et de plantes, l’organe de contrôle fixe pour chaque cas les distances entre les conducteurs des lignes aériennes et ces installations, et les mesures de protection adéquates.\n4 Les distances verticales entre les arbres et les conducteurs nus des lignes aériennes à haute tension ne doivent pas être inférieures, pour la flèche maximale, aux valeurs suivantes:\na. arbres fruitiers: 2,5 m + 0,01 m par kV de tension nominale;\nb. autres arbres: 1,5 m + 0,01 m par kV de tension nominale."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-35.it.json","api_md":"/api/v1/ch/lev/art-35.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_35","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-35","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_35","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-35","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-35/it/","kennung":"ch/lev/art-35","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 35","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"e28faa201a52a0e8c46a8edffca7efde8277f8a1efd20ce82759b7878dd3d7cd","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-35","titel":"Distanza dagli alberi","typ":"stelle","url":"/ch/lev/art-35/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Nel determinare le distanze dirette tra conduttori elettrici ed alberi va tenuto conto della coltivazione degli stessi, delle caratteristiche del suolo, della pendenza del terreno, della neve che può cadere dagli alberi, ecc.\n2 La distanza dagli alberi da frutta ed ornamentali situati sotto o accanto alle linee deve essere tale da permetterne la coltivazione senza pericolo.\n3 In presenza di impianti per innaffiare alberi e piante, si determinano caso per caso le distanze da osservare tra i getti di acqua ed i conduttori delle linee aeree, e le eventuali misure di protezione.\n4 Le distanze verticali tra gli alberi ed i conduttori nudi delle linee ad alta tensione non devono essere, in presenza della freccia massima, inferiori ai seguenti valori:\na. alberi da frutta: 2,5 m + 0,01 m per kV di tensione nominale;\nb. altri tipi di alberi: 1,5 m + 0,01 m per kV di tensione nominale."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-36.de.json","api_md":"/api/v1/ch/lev/art-36.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_36","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-36","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_36","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-36","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-36/de/","kennung":"ch/lev/art-36","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 36","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"bb86c2ae62fd55b072fa32d8d9bc9e6f5a49513587f579766580c001419b1820","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-36","titel":"Abstand zu Gebäuden","typ":"stelle","url":"/ch/lev/art-36/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Freileitungen müssen so weit von Gebäuden entfernt erstellt oder so ausgeführt werden, dass sie weder Menschen oder Gebäude gefährden noch bei einem Gebäudebrand Rettungs- und Löschmassnahmen behindern."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-36.fr.json","api_md":"/api/v1/ch/lev/art-36.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_36","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-36","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_36","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-36","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-36/fr/","kennung":"ch/lev/art-36","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 36","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"a688aaae065698f9b563901f725297d440a8267a319fb2d885d9185733fcff0e","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-36","titel":"Distance entre les lignes et les bâtiments","typ":"stelle","url":"/ch/lev/art-36/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les lignes aériennes doivent être établies à une distance des bâtiments telle qu’elles ne mettent pas en danger ni les personnes ni les bâtiments. La présence des lignes ne doit pas entraver les mesures de sauvetage et de lutte contre le feu en cas d’incendie."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-36.it.json","api_md":"/api/v1/ch/lev/art-36.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_36","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-36","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_36","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-36","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-36/it/","kennung":"ch/lev/art-36","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 36","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"3bcb74e509f790ef7967eab62838113a4c14cf3b9355d8075d5f85b8f2b4edec","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-36","titel":"Distanza dai fabbricati","typ":"stelle","url":"/ch/lev/art-36/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Le linee aeree devono essere disposte a distanze tali o realizzate in modo da non costituire pericolo né per le persone né per i fabbricati, e da non essere di ostacolo all’opera di salvataggio e di spegnimento del fuoco nel caso di incendio."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-37.de.json","api_md":"/api/v1/ch/lev/art-37.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_37","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-37","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_37","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-37","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-37/de/","kennung":"ch/lev/art-37","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 37","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"8988549e47cbba8a36d4d54633b309bbafc000fe71928a519f12781cf3c28414","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-37","titel":"Abstand von Niederspannungsleitungen zu Gebäuden","typ":"stelle","url":"/ch/lev/art-37/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Für Niederspannungsfreileitungen und -luftkabel gelten die Gebäudeabstände nach Anhang 7.\n2 Fassadenabspannungen sind so anzubringen, dass:\na. sie von allgemein zugänglicher Stelle aus nicht berührbar sind;\nb. die Freileitungen möglichst rechtwinklig zur Fassade ankommen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-37.fr.json","api_md":"/api/v1/ch/lev/art-37.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_37","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-37","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_37","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-37","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-37/fr/","kennung":"ch/lev/art-37","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 37","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"727286cb26ea2a9e3b7f5413cb9725c80e6d2cc5f8932866efe83c7b5607a00d","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-37","titel":"Distance entre les lignes à basse tension et les bâtiments","typ":"stelle","url":"/ch/lev/art-37/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les distances entre les lignes aériennes, les câbles aériens à basse tension et les bâtiments sont données à l’annexe 7.\n2 Les ancrages aux façades sont à fixer de façon:\na. qu’ils ne puissent être atteints à partir d’endroits normalement accessibles;\nb. que les lignes aériennes arrivent autant que possible perpendiculairement à la façade."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-37.it.json","api_md":"/api/v1/ch/lev/art-37.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_37","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-37","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_37","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-37","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-37/it/","kennung":"ch/lev/art-37","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 37","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"23c0df9f9a1774fe7e8472c8f96c0f24a8c4f1c9b4b5aa7d219e6da506c19360","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-37","titel":"Distanza delle linee a bassa tensione dai fabbricati","typ":"stelle","url":"/ch/lev/art-37/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Per quanto concerne le linee aeree a bassa tensione ed i cavi aerei a bassa tensione, valgono le distanze dai fabbricati di cui all’appendice 7.\n2 Gli ancoraggi alle facciate devono essere eseguiti in modo che:\na. non possano essere toccati da posti accessibili a tutti;\nb. le linee aeree si accostino alle facciate, per quanto possibile, perpendicolarmente alle stesse."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-38.de.json","api_md":"/api/v1/ch/lev/art-38.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_38","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-38","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_38","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-38","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-38/de/","kennung":"ch/lev/art-38","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 38","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"7b7e8d5c77ab611d91983b82b1f65476debf5464fc9f5e679fca0b8ce40c8f01","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-38","titel":"Abstand von Hochspannungsfreileitungen zu Gebäuden","typ":"stelle","url":"/ch/lev/art-38/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Für Hochspannungsfreileitungen gelten die Gebäudeabstände nach Anhang 8.\n2 Der Horizontalabstand von Hochspannungsleitern und ihren Tragwerken zu Gebäuden muss mindestens 5 m betragen und der Direktabstand zwischen Leitern und den nächstliegenden Gebäudeteilen bei Windauslenkung mindestens 2,50 m plus 0,01 m pro kV Nennspannung.\n3 Überragt das Gebäude den untersten Leiter, so erhöht sich der Horizontalabstand von 5 m um die Überragung des den Leitern nächstliegenden Gebäudeteils. Bei einer Dachneigung von über 45 wird die Überragung nach Anhang 8 Figur 2 berechnet. Ein Horizontalabstand von insgesamt 20 m genügt in jedem Fall.\n4 Überragt die Hochspannungsfreileitung das Gebäude, darf der Horizontalabstand ausnahmsweise unterschritten werden. Die Kontrollstelle entscheidet über:\na. die Zulässigkeit der Unterschreitung;\nb. die Direktabstände aufgrund der Brandbelastung und der Brandrisiken der Gebäude;\nc. die zu treffenden Schutzmassnahmen.\n5 Im Leitungsbereich dürfen sich keine Gebäude, Festhütten, Zelte oder ähnliche Einrichtungen mit grossen Menschenansammlungen, grossem Brandrisiko oder explosiblen Stoffen befinden. Die Kontrollstelle kann Ausnahmen bewilligen und Schutzmassnahmen vorschreiben.\n6 Hochspannungsfreileitungen dürfen nur an Gebäuden angebracht oder abgespannt werden, die ausschliesslich dem Betrieb elektrischer Anlagen dienen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-38.fr.json","api_md":"/api/v1/ch/lev/art-38.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_38","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-38","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_38","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-38","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-38/fr/","kennung":"ch/lev/art-38","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 38","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"fd5975f452e670670aba0e5eb6ec09732a683cf5835bec03f0469eb4778384b9","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-38","titel":"Distance entre les lignes aériennes à haute tension et les bâtiments","typ":"stelle","url":"/ch/lev/art-38/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les distances entre les lignes aériennes à haute tension et les bâtiments sont données à l’annexe 8.\n2 La distance horizontale entre les conducteurs à haute tension, leurs supports et les bâtiments doit être d’au moins 5 m. La distance directe entre les conducteurs et les parties de bâtiments les plus proches, en cas de déviations dues au vent, ne doit pas être inférieure à 2,50 m +0,01 m par kV de tension nominale.\n3 Pour les bâtiments plus élevés que le conducteur inférieur, la distance horizontale de 5 m doit être majorée d’une valeur égale à la hauteur du dépassement de la partie du bâtiment la plus proche du conducteur. Pour les toits ayant une pente supérieure à 45o, la valeur de dépassement se calcule selon l’annexe 8. Une distance horizontale de 20 m suffit dans tous les cas.\n4 Si les lignes aériennes à haute tension sont plus élevées que les bâtiments, la distance horizontale peut, exceptionnellement, être réduite. L’organe de contrôle décide alors:\na. si la réduction est admissible;\nb. des distances directes en fonction de la charge thermique et des risques d’incendie du bâtiment;\nc. des mesures de protection adéquates.\n5 Les bâtiments, les halles de fêtes, les tentes et les structures analogues destinées à d’importants rassemblements de personnes, avec de grands risques d’incendie ou des matières explosives ne doivent pas se trouver dans la zone de lignes aériennes. L’organe de contrôle peut autoriser des exceptions; il fixe alors les mesures de protection adéquates.\n6 Une ligne aérienne à haute tension ne peut être fixée ou ancrée à un bâtiment que si celui-ci sert exclusivement à l’exploitation d’installations électriques."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-38.it.json","api_md":"/api/v1/ch/lev/art-38.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_38","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-38","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_38","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-38","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-38/it/","kennung":"ch/lev/art-38","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 38","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"92789a90f24a0f7cfd01338753a4fb7ca08023765a008622a291e76559b479b0","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-38","titel":"Distanza delle linee aeree ad alta tensione dai fabbricati","typ":"stelle","url":"/ch/lev/art-38/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Per le linee aeree ad alta tensione valgono le distanze dai fabbricati di cui all’appendice 8.\n2 La distanza orizzontale dei conduttori ad alta tensione e dei relativi sostegni dai fabbricati deve essere almeno pari a 5 m, mentre la distanza diretta tra i conduttori e le parti più vicine dei fabbricati deve essere, in presenza di oscillazione impressa dal vento, almeno pari a 2,50 m + 0,01 m per ogni kV di tensione nominale.\n3 Per i fabbricati che superano in altezza il conduttore più basso, la distanza orizzontale di 5 m deve essere aumentata di un valore uguale alla differenza di altezza della parte di fabbricato più vicina ai conduttori. Per i tetti con declività superiore a 45°, la differenza di altezza si misura secondo l’appendice 8, figura 2. Una distanza orizzontale pari a 20 m è sufficiente in ogni caso.\n4 Se la linea aerea ad alta tensione sorpassa il fabbricato, la distanza orizzontale può essere in via eccezionale diminuita. L’organo di controllo decide in merito:\na. alla ammissibilità di una tale riduzione;\nb. alle distanze dirette necessarie in base al rischio di incendio dei fabbricati ed alla portata dell’incendio;\nc. alle eventuali misure protettive.\n5 Fabbricati, capannoni per manifestazioni, tendoni o impianti similari con concorso di numeroso pubblico, ad elevato rischio di incendio o contenenti esplosivi non devono trovarsi nella zona di rispetto delle linee aeree. L’organo di controllo può autorizzare eccezioni e prescrivere misure protettive.\n6 La fissazione o l’amarraggio delle linee aeree ad alta tensione ai fabbricati è permesso solo nel caso che i fabbricati servano esclusivamente all’esercizio di impianti elettrici."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-39.de.json","api_md":"/api/v1/ch/lev/art-39.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_39","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-39","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_39","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-39","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-39/de/","kennung":"ch/lev/art-39","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 39","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"df414a99055f8caadc88c99dc13cb955974682b4f778ad81f6568cdb63984e54","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-39","titel":"Areale mit grossen Menschenansammlungen, Spiel- und Sportanlagen","typ":"stelle","url":"/ch/lev/art-39/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Im Leitungsbereich von Hochspannungsfreileitungen dürfen sich keine Areale befinden, auf denen zeitweise grosse Menschenmengen vorkommen (Versammlungs-, Markt‑, Schausteller‑, Pausen‑, Sport‑, Campingplätze, öffentliche Liegewiesen usw.).\n2 Solche Areale dürfen ausnahmsweise überführt werden. Über Zulässigkeit der Überführung, Abstände und Schutzmassnahmen entscheidet die Kontrollstelle.\n3 Im Freileitungsbereich dürfen sich keine Wasserzonen (Bassin, See, Fluss usw.) von öffentlichen Schwimmbädern befinden. Für kleine Bassins kann die Kontrollstelle Ausnahmen bewilligen. Sie legt die zu treffenden Schutzmassnahmen fest.\n4 Werden Fussballfelder überführt, so ist zu Leitern und Luftkabeln ein Bodenabstand von mindestens 15 m einzuhalten. Dabei ist von einem Durchhang bei 40 °C Leitertemperatur auszugehen. Für Spielfelder von untergeordneter Bedeutung kann die Kontrollstelle ausnahmsweise kleinere Abstände bewilligen.\n5 Werden Spiel- und Sportanlagen überführt, so ist zwischen Leitern oder Luftkabeln und allfälligen Umzäunungen, Ballfangnetzen oder dergleichen ein Vertikalabstand von mindestens 2,50 m plus 0,01 m pro kV Nennspannung einzuhalten. Dabei ist von einem Durchhang bei 40 °C Leitertemperatur auszugehen.\n6 Tribünen, Klubhäuser, Garderoben und dergleichen von Spiel- und Sportanlagen gelten als Gebäude."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-39.fr.json","api_md":"/api/v1/ch/lev/art-39.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_39","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-39","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_39","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-39","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-39/fr/","kennung":"ch/lev/art-39","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 39","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"0c01febc02a91e271a06371bb58f25198b45967db797c4c80eeed09c65b3a6dd","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-39","titel":"Lieux d’importants rassemblements de personnes, places de jeux ou de sport","typ":"stelle","url":"/ch/lev/art-39/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les lieux où se regroupent temporairement un grand nombre de personnes (places de rassemblement, places de marché, lieux d’exposition, préaux d’écoles, places de sport, terrains de camping, aires de repos publiques, etc.) ne doivent pas se situer dans la zone d’une ligne aérienne à haute tension.\n2 Ces lieux peuvent être exceptionnellement survolés. L’organe de contrôle décide alors si le survol est admissible, des distances, et des mesures de protection adéquates.\n3 Le plan d’eau (piscine, lac, rivière, etc.) d’un établissement de bain public ne doit pas se trouver dans la zone de lignes aériennes. L’organe de contrôle peut autoriser des exceptions pour de petites piscines privées. Il fixe alors les mesures de protection adéquates.\n4 Au-dessus d’un terrain de football, la distance au sol des conducteurs et des câbles aériens doit atteindre au moins 15 m pour la flèche du conducteur à une température de 40 °C. L’organe de contrôle peut autoriser, à titre exceptionnel, des distances inférieures pour des terrains d’importance secondaire.\n5 Au-dessus des places de jeux ou de sport, la distance verticale entre les conducteurs ou les câbles aériens et tous les types de clôtures, treillis de protection, etc., ne doit pas être inférieure à 2,5 m + 0,01 m par kV de tension nominale pour la flèche du conducteur à une température de 40° C.\n6 Les tribunes, locaux des clubs, vestiaires et autres équipements similaires des places de jeux ou de sport sont considérés comme des bâtiments."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-39.it.json","api_md":"/api/v1/ch/lev/art-39.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_39","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-39","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_39","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-39","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-39/it/","kennung":"ch/lev/art-39","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 39","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"d77cb9ea167c0c224e941217eda02ff8d67c7fd826e9d2f5f546ac32facfc171","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-39","titel":"Luoghi con grande concorso di pubblico, impianti sportivi e campi di giuoco","typ":"stelle","url":"/ch/lev/art-39/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 I luoghi in cui si raccolgono temporaneamente molte persone (raduni, mercati, fiere, teatri, terreni di sport, camping, parchi pubblici di ricreazione e di distensione, ecc.) non devono trovarsi nella zona di rispetto delle linee aeree ad alta tensione.\n2 Detti luoghi possono essere eccezionalmente attraversati da linee aeree. L’organo di controllo decide sull’ammissibilità di una tale soluzione, sulle distanze da rispettare e sulle misure di protezione.\n3 Le acque (piscine, laghi, fiumi, ecc.) degli stabilimenti balneari pubblici non devono trovarsi nella zona di rispetto delle linee aeree. Per le piscine di piccole dimensioni, l’organo di controllo può autorizzare eccezioni fissando le eventuali misure protettive.\n4 Per quanto concerne i terreni di calcio, la distanza dei conduttori e dei cavi aerei dal suolo, considerata la freccia assunta dai conduttori ad una temperatura di 40° C degli stessi, deve essere di almeno 15 m. Per i campi di giuoco di secondaria importanza, l’organo di controllo può eccezionalmente autorizzare distanze più piccole.\n5 Per i campi di giuoco e gli impianti sportivi, la distanza verticale tra i conduttori od i cavi aerei e gli eventuali recinti, reti di protezione e simili, considerata la freccia assunta dai conduttori ad una temperatura di 40° C degli stessi, deve essere almeno pari a 2,50 m + 0,01 m per ogni kV di tensione nominale.\n6 Per tribune, sedi di circoli, vestiari e simili appartenenti ad impianti sportivi e di giuoco, valgono le disposizioni applicabili ai fabbricati."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-40.de.json","api_md":"/api/v1/ch/lev/art-40.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_40","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-40","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_40","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-40","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-40/de/","kennung":"ch/lev/art-40","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 40","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"9c37262335a647acddc63284381dac51a5a7216928dcb0421065197e25a3213d","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-40","titel":"Abstand zu Gewässern","typ":"stelle","url":"/ch/lev/art-40/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Freileitungen sind über Gewässern so zu erstellen, dass die Schifffahrt nicht beeinträchtigt wird.\n2 Leiter, Luftkabel und Erdleiter dürfen über folgenden Gewässerstrecken bei grösstem Durchhang den Abstand von 15 m plus 0,01 m pro kV Nennspannung über dem höchsten Schifffahrtswasserstand nicht unterschreiten:\na. Rhein, vom Bodensee bis zur Landesgrenze in Basel;\nb. Aare vom Bielersee bis Koblenz (Aaremündung);\nc. Broyekanal;\nd. Zihlkanal;\ne. Rhone, unterhalb von Genf bis zur Landesgrenze.\n3 Auf folgenden Strecken kann die Kontrollstelle kleinere Abstände zulassen, wenn dadurch die bestehende Schifffahrt nicht gefährdet wird:\na. Rhein, von Schaffhausen bis Koblenz (Aareeinmündung);\nb. Aare, von Biel bis zur Strassenbrücke Döttingen;\nc. Rhone, vom Kraftwerk Verbois bis zur Landesgrenze.\n4 Für alle übrigen Gewässerstrecken oder offene Gewässer mit bestehender oder möglicher Schifffahrt werden die Sicherheitsabstände und die zu treffenden Schutzmassnahmen von der Kontrollstelle im Einvernehmen mit den zuständigen Schifffahrtsbehörden festgelegt. Wenn nötig sind Schifffahrts- oder Warnzeichen anzubringen.\n5 Der Abstand von Leitern zu nicht schiffbaren Gewässern muss bei höchstem Pegelstand und grösstem Durchhang mindestens 4 m plus 0,01 m pro kV Nennspannung betragen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-40.fr.json","api_md":"/api/v1/ch/lev/art-40.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_40","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-40","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_40","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-40","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-40/fr/","kennung":"ch/lev/art-40","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 40","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"bc5172ced0db6c8eedc6c9a910694d36e096f8260927428e5c7b9fbacbe10df4","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-40","titel":"Distance entre les lignes et les cours d’eau","typ":"stelle","url":"/ch/lev/art-40/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les lignes situées au-dessus des cours d’eau doivent être disposées de façon à ne pas entraver la navigation.\n2 La distance entre les conducteurs, les câbles aériens, les conducteurs de terre et le niveau des hautes eaux navigables des cours d’eaux suivants ne doit pas être inférieure à 15 m + 0,01 m par kV de tension nominale, pour la flèche maximale des conducteurs:\na. le Rhin, du lac de Constance jusqu’à la frontière à Bâle;\nb. l’Aar, du lac de Bienne à Coblence (confluent du Rhin et de l’Aar);\nc. le canal de la Broye;\nd. le canal de la Thielle;\ne. le Rhône, en aval de Genève jusqu’à la frontière.\n3 L’organe de contrôle peut autoriser des distances plus petites sur les tronçons suivants si la navigation n’y est pas mise en danger:\na. sur le Rhin, de Schaffhouse à Coblence (confluent du Rhin et de l’Aar);\nb. sur l’Aar, de Bienne au pont routier de Döttingen;\nc. sur le Rhône, de l’usine de Verbois à la frontière.\n4 Pour tous les autres cours d’eau et lacs où la navigation est pratiquée ou pourrait l’être, l’organe de contrôle fixe, en accord avec les autorités compétentes de la navigation, les distances de sécurité requises et les mesures de protection adéquates. Si nécessaire, on placera des signaux de navigation ou de mise en garde.\n5 La distance entre les conducteurs et les cours d’eau et lacs non navigables, comptée pour la flèche maximale des conducteurs et le niveau des hautes eaux, doit être au minimum de 4 m plus 0,01 m par kV de tension nominale."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-40.it.json","api_md":"/api/v1/ch/lev/art-40.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_40","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-40","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_40","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-40","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-40/it/","kennung":"ch/lev/art-40","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 40","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"326cbf753b68231e2b6de956bc40429b0bb62b8bfe75b14430f49b71573b3c45","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-40","titel":"Distanza dalle acque","typ":"stelle","url":"/ch/lev/art-40/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le linee aeree che attraversano superfici d’acqua vanno disposte in modo da non ostacolare la navigazione.\n2 Relativamente ai corsi d’acqua sottoindicati, i conduttori, i cavi aerei ed i conduttori di terra non possono assumere, in presenza della freccia massima, una distanza inferiore a 15 m + 0,01 m per ogni kV di tensione nominale, misurata sul livello di massima piena ammesso per la navigazione:\na. Reno, dal lago di Costanza al confine nazionale a Basilea;\nb. Aare, dal lago di Bienna a Coblenza (foce dell’Aar);\nc. canale della Broye;\nd. canale della Zihl;\ne. Rodano, a valle di Ginevra fino al confine nazionale.\n3 Per le seguenti tratte, l’organo di controllo può ammettere distanze più piccole, purché la navigazione esistente non venga messa in pericolo:\na. Reno, da Sciaffusa a Coblenza (foce dell’Aar);\nb. Aar, da Bienna fino al ponte stradale di Döttingen;\nc. Rodano, dalla centrale di Verbois al confine nazionale.\n4 Per tutti gli altri corsi d’acqua, o per le altre acque aperte con navigazione esistente o possibile, le distanze di sicurezza e le misure di protezione da adottare sono fissate dall’organo di controllo d’intesa con le autorità della navigazione. Se necessario, si apporrà la segnaletica di navigazione o cartelli d’avvertimento.\n5 La distanza dei conduttori dalle acque non navigabili deve essere, in condizioni di massima piena ed in presenza della freccia massima, almeno pari a 4 m più 0,01 m per kV di tensione nominale."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-41.de.json","api_md":"/api/v1/ch/lev/art-41.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_41","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-41","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_41","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-41","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-41/de/","kennung":"ch/lev/art-41","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 41","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"13edc562130bc635270dea9f5a37d6ec3f80de67a26c96e2c87185ef2c97827c","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-41","titel":"Beleuchtungskörper an Hochspannungs-Tragwerken","typ":"stelle","url":"/ch/lev/art-41/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Beleuchtungskörper dürfen an Tragwerken von Hochspannungsfreileitungen nur dann angebracht werden, wenn:\na. Leitung und Instandhaltung der Beleuchtungsanlage dem gleichen Betriebsinhaber unterstellt sind;\nb. die beteiligten Betriebsinhaber Betrieb und Instandhaltung der Beleuchtungsanlage schriftlich vereinbart haben.\n2 Beleuchtungskörper müssen immer unterhalb der Hochspannungsleiter oder -luftkabel angebracht werden.\n3 Zwischen dem untersten Hochspannungsleiter oder ‑luftkabel und den Beleuchtungskörpern muss bei Regelleitungen ein Vertikalabstand von 1,5 m plus 0,01 m pro kV Nennspannung und bei Weitspannleitungen ein Vertikalabstand von 2,5 m plus 0,01 m pro kV Nennspannung eingehalten werden.\n4 Beleuchtungskörper und die dazugehörenden Installationen müssen auf den Tragwerken so angebracht und geerdet werden, dass sie bei einem Erdschluss im Hochspannungsnetz keinen unzulässigen Beeinflussungen ausgesetzt sind und keine gefährlichen Spannungen an andere Orte verschleppen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-41.fr.json","api_md":"/api/v1/ch/lev/art-41.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_41","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-41","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_41","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-41","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-41/fr/","kennung":"ch/lev/art-41","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 41","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"17a609e2a62b6daabd7dd3f88910bbb021a3ccf4dc5e8d2934c20563c1650af4","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-41","titel":"Luminaires sur les supports d’une ligne à haute tension","typ":"stelle","url":"/ch/lev/art-41/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les luminaires peuvent être montés sur des supports de lignes aériennes à haute tension:\na. si la ligne et l’entretien de l’installation d’éclairage sont sous la responsabilité du même exploitant;\nb. si l’exploitation et l’entretien de l’installation d’éclairage se font sur la base d’une convention écrite entre les exploitants concernés.\n2 Les luminaires doivent toujours être montés au-dessous des conducteurs ou des câbles aériens à haute tension.\n3 La distance verticale à respecter entre le conducteur inférieur ou le câble aérien à haute tension inférieur et les luminaires est pour les lignes ordinaires: de 1,5 m + 0,01 m par kV de tension nominale, pour les lignes à grandes portées: de 2,5 m + 0,01 m par kV de tension nominale.\n4 Les luminaires et leurs installations doivent être mis à la terre et fixés sur les supports de sorte qu’en cas de court-circuit à la terre dans le réseau haute tension ils ne soient pas soumis à des influences inadmissibles et ne disséminent aucune tension dangereuse dans leurs environs."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-41.it.json","api_md":"/api/v1/ch/lev/art-41.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_41","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-41","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_41","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-41","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-41/it/","kennung":"ch/lev/art-41","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 41","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"58a4fc407b26816adcd652a58db82419c19ac73202288074a789b802fcfd7d14","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-41","titel":"Sorgenti luminose sui sostegni delle linee ad alta tensione","typ":"stelle","url":"/ch/lev/art-41/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le sorgenti luminose possono essere fissate ai sostegni delle linee aeree ad alta tensione solo se:\na. linea e manutenzione dell’impianto di illuminazione dipendono dallo stesso esercente;\nb. gli esercenti interessati hanno concordato per iscritto l’esercizio e la manutenzione dell’impianto di illuminazione.\n2 Le sorgenti luminose devono essere applicate sempre al disotto dei conduttori o dei cavi aerei ad alta tensione.\n3 Nelle linee ordinarie, tra il conduttore o cavo aereo ad alta tensione più basso e le sorgenti luminose deve essere rispettata una distanza verticale pari a 1,5 m + 0,01 m per ogni kV di tensione nominale, mentre per le linee a grandi portate la distanza verticale è data da 2,5 m + 0,01 m per ogni kV di tensione nominale.\n4 Le sorgenti luminose e le relative installazioni devono essere applicate ai sostegni e messe a terra in modo che, nel caso di cortocircuito nella rete ad alta tensione, non risultino esposte a perturbazioni inammissibili e non possano convogliare tensioni pericolose in altri punti."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-42.de.json","api_md":"/api/v1/ch/lev/art-42.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_42","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-42","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_42","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-42","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-42/de/","kennung":"ch/lev/art-42","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 42","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"3bcc1e8f02cc329e9ee0f5eef6e7a381ced826ff72b4d071c421ee1ba7723c68","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-42","titel":"Kandelaber","typ":"stelle","url":"/ch/lev/art-42/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Hochspannungsleiter und -luftkabel müssen zu Kandelabern und Beleuchtungskörpern mindestens die Abstände nach Anhang 9 aufweisen.\n2 Kandelaber dürfen nur im Einverständnis mit dem Betriebsinhaber der Hochspannungsfreileitung aufgestellt oder umgelegt werden, wenn die Gefahr besteht, dass durch unbeabsichtigte oder beabsichtigte Bewegungen des Kandelabers der Direktabstand «a» nach Anhang 9 unterschritten wird.\n3 Instandhaltungsarbeiten an Beleuchtungskörpern und Kandelabern dürfen durch vorbeiführende Hochspannungsfreileitungen weder behindert werden, noch darf dabei für das Personal eine Gefährdung auftreten. Windauslenkungen der Leiter oder der Kandelaber dürfen nicht zu Spannungsüberschlägen führen.\n4 Überragen die Beleuchtungskörper einer Kandelaberreihe, die von einer Hochspannungsfreileitung gekreuzt wird, deren unterste Leiter oder befinden sie sich auf gleicher Höhe mit ihnen, so ist beidseits der Kreuzungsstelle sowohl bei den Beleuchtungskörpern als auch an den Kandelaberfüssen auf die tiefliegenden Leiter aufmerksam zu machen.\n5 Bevor an Kandelabern, die sich in der Nähe von Hochspannungsfreileitungen mit Nennspannungen von mehr als 100 kV befinden, gearbeitet wird, sind die elektrischen Installationen und Armaturen der Kandelaber zu erden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-42.fr.json","api_md":"/api/v1/ch/lev/art-42.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_42","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-42","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_42","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-42","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-42/fr/","kennung":"ch/lev/art-42","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 42","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"7aec5c040b48fd096f2187ee64682fef75a40be7a1bd97a35e1144b767effb84","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-42","titel":"Candélabres","typ":"stelle","url":"/ch/lev/art-42/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les distances requises entre un conducteur, un câble aérien à haute tension et des candélabres ou des luminaires sont données à l’annexe 9.\n2 La pose ou le démontage d’un candélabre ne doit se faire qu’avec l’accord de l’exploitant de la ligne aérienne à haute tension si le risque existe, suite à des mouvements intentionnels ou accidentels imprimés au candélabre, que la distance directe «a» prescrite à l’annexe 9 ne soit plus respectée.\n3 Les travaux d’entretien des luminaires et des candélabres ne doivent pas être entravés par des lignes aériennes à haute tension passant à proximité; le personnel doit pouvoir travailler sans danger. Des déviations du conducteur ou du candélabre dues au vent ne doivent pas provoquer d’arcs électriques.\n4 Aux croisements de lignes aériennes à haute tension avec une rangée de candélabres dont les luminaires sont situés plus hauts ou au même niveau que les conducteurs inférieurs de ces lignes, on attirera l’attention sur la présence de ces conducteurs en plaçant des panneaux d’avertissement sur les luminaires et au pied des candélabres, de chaque côté du point de croisement.\n5 Pour des candélabres placés dans la zone de lignes aériennes à haute tension dont les tensions nominales dépassent 100 kV, on mettra l’installation électrique et les armatures des candélabres à la terre avant d’entreprendre un quelconque travail."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-42.it.json","api_md":"/api/v1/ch/lev/art-42.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_42","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-42","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_42","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-42","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-42/it/","kennung":"ch/lev/art-42","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 42","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"35c84e16790a55a69910161703d2562bba1dd107e4c4a9b4ab9004564cd0fcdd","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-42","titel":"Sostegni di illuminazione","typ":"stelle","url":"/ch/lev/art-42/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le distanze dei conduttori e dei cavi aerei ad alta tensione dai sostegni di illuminazione e dalle sorgenti luminose devono essere almeno pari ai valori secondo l’appendice 9.\n2 Il montaggio o lo spostamento di sostegni di illuminazione può avvenire solo d’intesa con gli esercenti delle linee aeree ad alta tensione qualora, in seguito a movimenti casuali o voluti del sostegno stesso, esista il pericolo che la distanza diretta possa divenire inferiore al valore «a» di cui all’appendice 9.\n3 I lavori di manutenzione alle sorgenti luminose ed ai loro sostegni non devono essere ostacolati o resi pericolosi per il personale dalla presenza di linee aeree ad alta tensione. Le deviazioni dei conduttori o dei sostegni di illuminazione sotto la spinta del vento non devono provocare scariche elettriche.\n4 Nel caso di incroci di linee aeree ad alta tensione con una fila di sostegni di illuminazione le cui sorgenti luminose superano in altezza i conduttori più bassi o sono a pari altezza degli stessi, occorre richiamare l’attenzione da ambedue le parti dell’incrocio, sia presso le sorgenti luminose che al piede dei sostegni di illuminazione, sulla presenza di questi conduttori bassi sotto tensione.\n5 Prima di iniziare lavori ai sostegni di illuminazione situati in prossimità di linee aeree ad alta tensione con tensione nominale superiore a 100 kV, gli impianti elettrici e le morsetterie dei sostegni di illuminazione devono essere messi a terra."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-43.de.json","api_md":"/api/v1/ch/lev/art-43.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_43","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-43","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_43","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-43","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-43/de/","kennung":"ch/lev/art-43","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 43","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"c54f66562582d74e2a3a33d5e46d08acfec0e1e3b9de59dd5aaf40480c2849ee","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-43","titel":"Verkehrsschilder und Schutzwände","typ":"stelle","url":"/ch/lev/art-43/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Für Verkehrsschilder und permanente Schutzwände gelten die gleichen Abstände wie für Kandelaber.\n2 Instandhaltungsarbeiten an Verkehrsschildern, Schutzwänden oder dergleichen dürfen durch vorbeiführende Freileitungen weder behindert werden, noch darf dabei für das Personal eine Gefährdung auftreten."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-43.fr.json","api_md":"/api/v1/ch/lev/art-43.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_43","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-43","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_43","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-43","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-43/fr/","kennung":"ch/lev/art-43","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 43","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"fc873fe0eb2cd743e0e6d26ccad25eb98a05947afca6d74cc0d8a84b48be9bfd","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-43","titel":"Panneaux de signalisation et parois de protection","typ":"stelle","url":"/ch/lev/art-43/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les distances valables pour les panneaux de signalisation et les parois de protection permanentes sont les mêmes que pour les candélabres.\n2 Les travaux d’entretien des panneaux de signalisation, des parois de protection ou objets similaires ne doivent pas être entravés par des lignes aériennes proches; le personnel doit pouvoir travailler sans danger."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-43.it.json","api_md":"/api/v1/ch/lev/art-43.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_43","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-43","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_43","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-43","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-43/it/","kennung":"ch/lev/art-43","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 43","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"93f9f62a9c3616e77def2bbac67861d07c57cd81253597b8458d95d307a79415","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-43","titel":"Segnaletica stradale e pareti di protezione","typ":"stelle","url":"/ch/lev/art-43/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Per i cartelli di segnalazione e le pareti di protezione permanenti valgono le distanze applicabili ai sostegni di illuminazione.\n2 La presenza di linee aeree non deve ostacolare i lavori di manutenzione alla segnaletica stradale, alle pareti di protezione e simili, e non deve costituire pericolo per il personale."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-44.de.json","api_md":"/api/v1/ch/lev/art-44.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_44","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-44","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_44","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-44","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-44/de/","kennung":"ch/lev/art-44","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 44","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"a1682600425d6a3db2f98b07785b6300751568812a6e87632afffb5062325187","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-44","titel":"Schiessplätze","typ":"stelle","url":"/ch/lev/art-44/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Die Abstände zwischen Freileitungen und Schiessanlagen für das Schiesswesen ausser Dienst mit Ordonnanzmunition bestimmen sich nach Anhang 10. Die Abstände können unterschritten werden, wenn die Leitungen durch Blenden geschützt sind oder in schusstoten Räumen liegen.\n2 Die Abstände zwischen Freileitungen und Schiessanlagen für Sport- und Jagdschiessen werden von der Kontrollstelle festgelegt. Diese bestimmt zudem die zu treffenden Schutzmassnahmen.\n3 Die Kontrollstelle entscheidet darüber, ob Freileitungen über Scheibenstände oder Scheibenanlagen geführt werden dürfen. Sie bestimmt die Direktabstände sowie die zu treffenden Schutzmassnahmen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-44.fr.json","api_md":"/api/v1/ch/lev/art-44.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_44","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-44","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_44","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-44","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-44/fr/","kennung":"ch/lev/art-44","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 44","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"5cbd6f7deafc08fab8241004f4549e3f06530b0c0f96e659d95cbee4a2acc16c","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-44","titel":"Places de tir","typ":"stelle","url":"/ch/lev/art-44/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les distances à respecter entre les lignes aériennes et les places pour le tir hors service avec munitions d’ordonnance sont données à l’annexe 10. Ces distances peuvent être réduites si les lignes sont protégées par des pare-balles ou si elles sont situées dans un angle mort.\n2 Les distances à respecter entre les lignes aériennes et les installations de tir sportif ou de tir de chasse ainsi que les mesures de protection adéquates sont fixées par l’organe de contrôle.\n3 Si les lignes aériennes passent au-dessus de cibleries ou d’installations de cibles, l’organe de contrôle décide si le survol est admissible, des distances directes, et des mesures de protection adéquates."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-44.it.json","api_md":"/api/v1/ch/lev/art-44.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_44","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-44","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_44","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-44","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-44/it/","kennung":"ch/lev/art-44","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 44","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"a303d6772cc8f5976513ec665450b05cc51df9f0e922830657ea69d2353c97e8","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-44","titel":"Poligoni di tiro","typ":"stelle","url":"/ch/lev/art-44/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le distanze tra le linee aeree e gli impianti di tiro per esercitazioni fuori servizio con munizioni di ordinanza vengono definite secondo l’appendice 10. Le distanze possono essere ridotte se le linee risultano protette da schermi o si trovano fuori della zona di tiro.\n2 Le distanze tra le linee aeree e gli impianti di tiro sportivi o di caccia sono fissate dall’organo di controllo. Quest’ultimo definisce inoltre le misure di protezione da adottare.\n3 L’organo di controllo decide se le linee aeree possono essere fatte passare sopra gli stand dei bersagli o gli impianti dei bersagli. Esso fissa le distanze dirette e le misure di protezione da adottare."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-45.de.json","api_md":"/api/v1/ch/lev/art-45.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_45","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-45","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_45","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-45","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-45/de/","kennung":"ch/lev/art-45","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 45","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"513d4b489b4c9666bb81e19809fa3469478160c51f47fd74929b7723faeb71d0","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-45","titel":"Leiter und Tragelemente von Luftkabeln","typ":"stelle","url":"/ch/lev/art-45/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Leiter müssen einen Durchmesser von mindestens 5 mm und einen Querschnitt von mindestens 19,6 mm2 sowie eine Mindestbruchkraft von 5,5 kN aufweisen. Für Leiter aus Reinaluminium sowie metallene Tragelemente von Luftkabeln muss der Querschnitt mindestens 50 mm2 betragen.\n2 Für Leiter mit einem Querschnitt von mehr als 50 mm2 und für alle Reinaluminiumleiter sowie für metallene Tragelemente von Luftkabeln sind nur Seile zulässig.\n3 Die höchstzulässige Zugbeanspruchung der Werkstoffe von Leitern oder Tragelementen bestimmt sich nach Anhang 11. Werden Werkstoffe verwendet, die in diesem Anhang nicht aufgeführt sind, so ist eine Zugbeanspruchung von höchstens 2/3 der Bruchgrenze zulässig. Die Kontrollstelle kann Prüfatteste von anerkannten Prüfstellen verlangen.\n4 Bei Verbundseilen darf die zulässige Zugbeanspruchung der einzelnen Werkstoffe nicht überschritten werden. Wird ein Werkstoff als alleiniges Tragelement benützt, so müssen die übrigen Werkstoffe als zusätzliche Last berücksichtigt werden.\n5 Bei Luftkabeln ohne separate Tragelemente sind mindestens zwei Leiter als Tragelemente zu benutzen. In Niederspannungskabeln darf aber der PEN-Leiter oder der Schutzleiter PE nicht als Tragelement benützt werden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-45.fr.json","api_md":"/api/v1/ch/lev/art-45.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_45","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-45","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_45","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-45","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-45/fr/","kennung":"ch/lev/art-45","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 45","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"8285518ff4ce79e0218eba29112de850b0e5f894f7f3f89b10656b766836455f","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-45","titel":"Conducteurs et éléments porteurs de câbles aériens","typ":"stelle","url":"/ch/lev/art-45/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les conducteurs doivent présenter un diamètre minimum de 5 mm, une section minimum de 19,6 mm2, et une charge de rupture minimale de 5,5 kN. La section d’un conducteur en aluminium pur ou d’un élément métallique porteur de câble aérien doit être au minimum de 50 mm2.\n2 Pour les conducteurs d’une section supérieure à 50 mm2 et pour tous les conducteurs en aluminium pur ainsi que pour les éléments métalliques porteurs de câbles aériens, seules des cordes sont admises.\n3 La contrainte maximale admissible à la traction des matériaux utilisés pour des conducteurs et des éléments porteurs est donnée à l’annexe 11. En cas d’utilisation de matériaux non mentionnés dans cette annexe, la contrainte admissible ne doit pas être supérieure aux 2/3 de la contrainte de rupture. L’organe de contrôle peut exiger un certificat d’essais d’une station d’essais reconnue.\n4 Pour les cordes compound, la contrainte admissible à la traction ne doit être dépassée pour aucun des matériaux entrant dans leur composition. Lorsque l’un des matériaux est utilisé comme élément porteur unique, les autres matériaux sont considérés comme des charges supplémentaires.\n5 Pour des câbles aériens sans éléments porteurs séparés, il faut utiliser au moins deux conducteurs comme éléments porteurs. Le conducteur PEN ou le conducteur de protection PE de câbles à basse tension ne doit jamais être utilisé comme élément porteur."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-45.it.json","api_md":"/api/v1/ch/lev/art-45.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_45","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-45","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_45","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-45","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-45/it/","kennung":"ch/lev/art-45","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 45","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"1e129a596781eec95a29b70e9460b24479eda961b6d666740044c6a4524d1b01","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-45","titel":"Conduttori ed elementi portanti dei cavi aerei","typ":"stelle","url":"/ch/lev/art-45/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 I conduttori devono avere un diametro di almeno 5 mm, una sezione di almeno 19,6 mm2 e un carico di rottura minimo pari a 5,5 kN. Per i conduttori di alluminio puro e gli elementi portanti metallici dei cavi aerei, la sezione deve essere pari ad almeno 50 mm2.\n2 Per i conduttori di sezione superiore a 50 mm2, per tutti i conduttori di alluminio puro e per gli elementi portanti metallici dei cavi aerei sono ammesse solo corde.\n3 La sollecitazione massima alla trazione ammessa per i materiali dei conduttori o degli elementi portanti si determina secondo l’appendice 11. Nel caso di impiego di materiali non riportati in questa appendice, la sollecitazione ammissibile non deve superare i 2/3 del carico di rottura. L’organo di controllo può esigere attestati di prova rilasciati da istituti di prova riconosciuti.\n4 Nel caso di corde composite, la sollecitazione massima alla trazione ammessa non deve essere superata per nessuno dei materiali impiegati. Se un materiale viene impiegato quale unico elemento portante, gli altri materiali devono essere considerati come sovraccarico.\n5 Per i cavi aerei senza elementi portanti separati, occorre impiegare almeno due conduttori quali elementi portanti. Tuttavia, il conduttore PEN o il conduttore di protezione PE dei cavi a bassa tensione non può essere mai impiegato come elemento portante."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-46.de.json","api_md":"/api/v1/ch/lev/art-46.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_46","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-46","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_46","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-46","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-46/de/","kennung":"ch/lev/art-46","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 46","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"7e7092462bc36eaa714ba38711711cc9028f884409c3a5f05f20353614b9c929","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-46","titel":"Grösster Leiterzug","typ":"stelle","url":"/ch/lev/art-46/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Die maximal zu erwartende Zugbeanspruchung eines Leiters ist aufgrund folgender Annahmen zu berechnen:\na. einer Leitertemperatur von –20 °C ohne Zusatzlast;\nb. einer Leitertemperatur von 0 °C und einer gleichmässig verteilten Zusatzlast von mindestens 20 N/m pro Leiter oder Teilleiter, ohne Wind.\n2 Sind aufgrund der örtlichen Verhältnisse tiefere Temperaturen oder grössere Zusatzlasten zu erwarten, so sind diese der Berechnung zugrunde zu legen.\n3 Bei Luftkabeln gelten die Temperaturannahmen immer für das Tragelement. Das Kabelgewicht bzw. die nicht als Tragelement dienenden Leiter sind zur Zusatzlast zu addieren."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-46.fr.json","api_md":"/api/v1/ch/lev/art-46.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_46","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-46","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_46","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-46","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-46/fr/","kennung":"ch/lev/art-46","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 46","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"e9c6dd6b0109d03632db31847fb39b25fdc6b2a1088a7dc91f54c134e32c801a","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-46","titel":"Contrainte maximale à la traction des conducteurs","typ":"stelle","url":"/ch/lev/art-46/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 La contrainte maximale à la traction d’un conducteur se calcule à partir des hypothèses suivantes:\na. une température du conducteur de –20° C, sans surcharge;\nb. une température du conducteur de 0° C et une surcharge uniformément répartie d’au moins 20 N/m sur chaque conducteur ou conducteur partiel, sans vent.\n2 Si les conditions locales montrent que des températures plus basses ou des surcharges plus fortes sont à prévoir, on les introduira dans le calcul.\n3 Pour les câbles aériens, les hypothèses de température sont toujours valables pour l’élément porteur. Le poids du câble ou des conducteurs qui ne tiennent pas lieu d’élément porteur est à ajouter à la surcharge."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-46.it.json","api_md":"/api/v1/ch/lev/art-46.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_46","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-46","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_46","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-46","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-46/it/","kennung":"ch/lev/art-46","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 46","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"01d77e692944c559785746cd10d27661874ee27f84d02576bd13797fbe15f2d6","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-46","titel":"Trazione massima sui conduttori","typ":"stelle","url":"/ch/lev/art-46/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Per il calcolo della sollecitazione massima presumibile alla trazione a cui può essere sottoposto un conduttore, si assumono le seguenti ipotesi:\na. una temperatura del conduttore pari a –20° C, senza sovraccarico;\nb. una temperatura del conduttore pari a 0° C ed un sovraccarico distribuito uniformemente pari ad almeno 20 N/m per conduttore o parte di conduttore, in assenza di vento.\n2 Se, sulla base delle condizioni locali, bisogna attendersi temperature più basse o sovraccarichi maggiori, saranno queste ultime condizioni ad essere assunte quali ipotesi di calcolo.\n3 Per i cavi aerei, le ipotesi relative alle temperature si riferiscono sempre agli elementi portanti. Il peso del cavo o i conduttori che non servono da elementi portanti devono essere aggiunti al sovraccarico."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-47.de.json","api_md":"/api/v1/ch/lev/art-47.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_47","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-47","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_47","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-47","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-47/de/","kennung":"ch/lev/art-47","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 47","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"88f6bcfd2089258e83e5996a8016e9350f7528951ecb51ae96cc550b6a58cdb6","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-47","titel":"Grösster Leiterdurchhang","typ":"stelle","url":"/ch/lev/art-47/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Der maximal zu erwartende Durchhang eines Leiters ist aufgrund folgender Annahmen zu berechnen:\na. einer Leitertemperatur von 40 °C;\nb. einer Leitertemperatur von 0 °C und einer gleichmässig verteilten Zusatzlast von mindestens 20 N/m pro Leiter oder Teilleiter, ohne Wind.\n2 Sind aufgrund der örtlichen Verhältnisse höhere Temperaturen oder grössere Zusatzlasten zu erwarten, so sind diese der Berechnung zugrunde zu legen.\n3 Bei Luftkabeln gelten die Temperaturannahmen immer für das Tragelement. Das Kabelgewicht bzw. die nicht als Tragelement dienenden Leiter sind zur Zusatzlast zu addieren."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-47.fr.json","api_md":"/api/v1/ch/lev/art-47.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_47","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-47","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_47","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-47","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-47/fr/","kennung":"ch/lev/art-47","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 47","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"c71d451727bb13ba9867be9d3843f5d0623aede89993d3a84d18397801dd8897","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-47","titel":"Flèche maximale des conducteurs","typ":"stelle","url":"/ch/lev/art-47/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 La flèche maximale d’un conducteur se calcule à partir des hypothèses suivantes:\na. une température du conducteur de 40° C;\nb. une température du conducteur de 0° C et une surcharge uniformément répartie d’au moins 20 N/m sur chaque conducteur ou conducteur partiel, sans vent.\n2 Si les conditions locales montrent que des températures plus élevées ou des surcharges plus fortes sont à prévoir, on les introduira dans le calcul.\n3 Pour les câbles aériens, les hypothèses de température sont toujours valables pour l’élément porteur. Le poids du câble ou des conducteurs qui ne tiennent pas lieu d’élément porteur est à ajouter à la surcharge."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-47.it.json","api_md":"/api/v1/ch/lev/art-47.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_47","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-47","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_47","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-47","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-47/it/","kennung":"ch/lev/art-47","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 47","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"15104bf4d2bdccb4b9ea2d0ebb29168c3917d791309534243628d957628ce506","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-47","titel":"Freccia massima dei conduttori","typ":"stelle","url":"/ch/lev/art-47/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Per il calcolo della freccia massima presumibile di un conduttore, si assumono le seguenti ipotesi:\na. una temperatura del conduttore pari a 40° C;\nb. una temperatura del conduttore pari a 0° C ed un sovraccarico distribuito uniformemente pari ad almeno 20 N/m per conduttore o parte di conduttore, in assenza di vento.\n2 Se, sulla base delle condizioni locali, bisogna attendersi temperature più alte o sovraccarichi maggiori, saranno queste ultime condizioni ad essere assunte quali ipotesi di calcolo.\n3 Per i cavi aerei, le ipotesi relative alle temperature si riferiscono sempre agli elementi portanti. Il peso del cavo o i conduttori che non servono da elementi portanti devono essere aggiunti al sovraccarico."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-48.de.json","api_md":"/api/v1/ch/lev/art-48.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_48","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-48","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_48","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-48","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-48/de/","kennung":"ch/lev/art-48","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 48","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"843c831d78c7d87358d29b7821cdc7e24c5c550c98dbbad1125f676c633b0105","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-48","titel":"Zugbeanspruchung und Leiterdurchhang von Regelleitungen","typ":"stelle","url":"/ch/lev/art-48/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Zugbeanspruchung und Leiterdurchhang von Regelleitungen bestimmen sich nach Anhang 12."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-48.fr.json","api_md":"/api/v1/ch/lev/art-48.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_48","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-48","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_48","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-48","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-48/fr/","kennung":"ch/lev/art-48","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 48","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"dc566ddaae1d6cdca04fe7256f22407cce7960016d1b6e401333b5cad3449d7d","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-48","titel":"Contrainte à la traction et flèche de lignes ordinaires","typ":"stelle","url":"/ch/lev/art-48/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"L’annexe 12 donne les contraintes à la traction et les flèches des conducteurs pour les lignes ordinaires."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-48.it.json","api_md":"/api/v1/ch/lev/art-48.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_48","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-48","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_48","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-48","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-48/it/","kennung":"ch/lev/art-48","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 48","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"1d16994f488be271d65fa741262f9c3df5d8d20c4c35b1a7179c157a81aedabf","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-48","titel":"Sollecitazione alla trazione e freccia delle linee ordinarie","typ":"stelle","url":"/ch/lev/art-48/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Le sollecitazioni a trazione e le frecce delle linee ordinarie si calcolano secondo l’appendice 12."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-49.de.json","api_md":"/api/v1/ch/lev/art-49.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_49","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-49","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_49","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-49","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-49/de/","kennung":"ch/lev/art-49","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 49","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"85ebf0edc484b1b7f45a20270a2b63d559a71d6fcd2d31521a9b7c8d9a3ff854","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-49","titel":"Leiterverbindungen","typ":"stelle","url":"/ch/lev/art-49/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Die Bruchkraft der zugfesten Verbindungen von Leitern oder Tragelementen von Luftkabeln muss mindestens 90 Prozent derjenigen des Leiters oder des Tragelementes betragen.\n2 Wird der Querschnitt eines auf Zug beanspruchten Leiters durch eine Beschädigung um mehr als 25 Prozent vermindert, so hat die Reparaturstelle den Anforderungen für zugfeste Leiterverbindungen zu genügen.\n3 Freileitungen dürfen nicht aus mehreren kurzen Leiterstücken zusammengesetzt werden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-49.fr.json","api_md":"/api/v1/ch/lev/art-49.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_49","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-49","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_49","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-49","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-49/fr/","kennung":"ch/lev/art-49","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 49","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"fd85724cf2bfffea97c00ead918ac3a45e476229b28ec6ece7c595b914ebaea6","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-49","titel":"Jonctions de conducteurs","typ":"stelle","url":"/ch/lev/art-49/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 La charge de rupture des manchons de jonction résistant à la traction des conducteurs et des éléments porteurs de câbles aériens doit atteindre au moins 90 % de celle du conducteur ou de l’élément porteur.\n2 Lorsque la section d’un conducteur soumis à un effort de traction subit, suite à une détérioration, une réduction de plus de 25 %, le point de réparation doit répondre aux exigences d’un manchon de jonction résistant à la traction.\n3 L’utilisation de courts tronçons de conducteurs assemblés n’est pas admise pour une ligne aérienne."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-49.it.json","api_md":"/api/v1/ch/lev/art-49.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_49","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-49","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_49","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-49","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-49/it/","kennung":"ch/lev/art-49","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 49","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"936c02cdb909f61f9b09c4193259acc9b70551d863dd584eee242313f38542a5","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-49","titel":"Giunzioni dei conduttori","typ":"stelle","url":"/ch/lev/art-49/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Il carico di rottura delle giunzioni sollecitate a trazione dei conduttori e degli elementi portanti dei cavi aerei deve raggiungere almeno il 90 per cento del limite di rottura del conduttore o dell’elemento portante.\n2 Se, nel caso di danneggiamento di un conduttore sottoposto allo sforzo di tra-zione, la sezione dello stesso presenta una riduzione superiore al 25 per cento, il punto di riparazione deve soddisfare le esigenze imposte alle giunzioni solle-citate a trazione.\n3 Le linee aeree non possono essere costituite dall’unione di più spezzoni di conduttori."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-50.de.json","api_md":"/api/v1/ch/lev/art-50.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_50","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-50","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_50","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-50","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-50/de/","kennung":"ch/lev/art-50","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 50","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"824836d9aafab3f5f18ae2ba0ae3455e173fd893aaaa5d6116e3e6d474e18d85","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-50","titel":"Isolatoren","typ":"stelle","url":"/ch/lev/art-50/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Stab‑, Stütz- und Stützenisolatoren aus keramischen Werkstoffen oder aus Glas müssen, bezogen auf ihre Mindestbruchkraft folgende Sicherheitsfaktoren aufweisen:\na. mindestens 1,25 bei Beanspruchung durch die elektrodynamischen Kräfte der Leiter infolge Kurzschlussströmen;\nb. mindestens 2,8 bei Beanspruchung durch die grössten statischen Belastungen.\n2 Kappen-Bolzen-Isolatoren aus keramischen Werkstoffen oder aus Glas müssen folgende Sicherheitsfaktoren aufweisen:\na. mindestens 1,25, bezogen auf ihre Mindestbruchkraft, bei Beanspruchung durch die elektrodynamischen Kräfte der Leiter infolge Kurzschlussströmen;\nb. mindestens 3,5, bezogen auf ihre elektromechanische Bruchkraft, bei Beanspruchung durch die grössten statischen Belastungen.\n3 Verbundisolatoren aus Kunststoff müssen witterungsbeständig und gegen UV-Strahlung resistent sein."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-50.fr.json","api_md":"/api/v1/ch/lev/art-50.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_50","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-50","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_50","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-50","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-50/fr/","kennung":"ch/lev/art-50","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 50","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"9c9cd4f3e1cc0785647e86dc71460953b96eacbf8c7a798b20cf4f4313e4a364","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-50","titel":"Isolateurs","typ":"stelle","url":"/ch/lev/art-50/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les isolateurs en céramique ou en verre, qu’ils soient à long fût, supports ou rigides à tige, doivent présenter les coefficients de sécurité suivants par rapport à leur charge de rupture minimale:\na. au minimum 1,25 en cas de sollicitations par les forces électrodynamiques du conducteur résultant de courants de courts-circuits;\nb. au minimum 2,8 en cas de sollicitations par les charges statiques maximales.\n2 Les isolateurs en céramique ou en verre à capots et tiges doivent présenter les coefficients de sécurité suivants:\na. au minimum 1,25 par rapport à leur charge de rupture minimale, en cas de sollicitations par les forces électrodynamiques du conducteur résultant de courants de courts-circuits;\nb. au minimum 3,5 par rapport à leur charge de rupture électromécanique, en cas de sollicitations par les forces statiques maximales.\n3 Les isolateurs composites en matière synthétique doivent être résistants aux intempéries et au rayonnement ultraviolet."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-50.it.json","api_md":"/api/v1/ch/lev/art-50.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_50","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-50","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_50","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-50","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-50/it/","kennung":"ch/lev/art-50","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 50","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"1a728d0612b2ca7a5deefa68a198c64ec6dc87bc36d259ea65a0d03f7a980a59","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-50","titel":"Isolatori","typ":"stelle","url":"/ch/lev/art-50/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Gli isolatori a bastone, gli isolatori rigidi a perno e gli isolatori rigidi a base di materiale ceramico o di vetro devono presentare, con riferimento al carico minimo di rottura, i seguenti fattori di sicurezza:\na. non inferiore a 1,25, quando sollecitati dalle forze elettrodinamiche esercitate dai conduttori percorsi dalle correnti di cortocircuito;\nb. non inferiore a 2,8, quando sollecitati dalle forze statiche massime.\n2 Gli isolatori a cappa e perno di materiali ceramici o di vetro devono presentare i seguenti fattori di sicurezza:\na. non inferiore a 1,25, riferito al carico minimo di rottura, quando sollecitati dalle forze elettrodinamiche esercitate dai conduttori percorsi dalle correnti di cortocircuito;\nb. non inferiore a 3,5, riferito al carico di rottura elettromeccanico, quando sollecitati dalle forze statiche massime.\n3 Gli isolatori compositi di materiale sintetico devono resistere alle intemperie ed all’azione dei raggi ultravioletti."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-51.de.json","api_md":"/api/v1/ch/lev/art-51.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_51","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-51","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_51","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-51","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-51/de/","kennung":"ch/lev/art-51","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 51","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"c8e481ef35e370c0f82d686c3a40a1303b6b174c2eac2d201ac49be75aad3fb3","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-51","titel":"Isolatoren in Mehrfachketten","typ":"stelle","url":"/ch/lev/art-51/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Werden Mehrfachaufhängungen oder Mehrfachabspannungen der Leiter als zusätzliche Schutzmassnahme verlangt, so müssen die Sicherheitsfaktoren nach Artikel 50 auch nach dem Versagen einer Teilaufhängung oder Teilabspannung noch gewährleistet sein.\n2 Die Isolatorenketten sind in diesem Fall an mindestens zwei getrennten Punkten an den Tragwerken zu befestigen.\n3 Beim Versagen einer Teilaufhängung müssen die verbleibenden Elemente einer Mehrfachaufhängung oder ‑abspannung den auftretenden dynamischen Belastungen standhalten.\n4 Die einzelnen Isolatorenketten solcher Mehrfachaufhängungen dürfen aus höchstens drei Isolatoren bestehen, wenn die einzelnen Isolatoren kürzer sind als 0,5 m."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-51.fr.json","api_md":"/api/v1/ch/lev/art-51.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_51","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-51","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_51","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-51","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-51/fr/","kennung":"ch/lev/art-51","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 51","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"47d6d8079605a3a9b3312808c84984ac863394dc02e43621423d5583cf802430","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-51","titel":"Isolateurs à chaînes multiples","typ":"stelle","url":"/ch/lev/art-51/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Lorsque des suspensions multiples ou des ancrages multiples de conducteurs sont exigés à titre de mesure de protection supplémentaire, les coefficients de sécurité mentionnés à l’art. 50 doivent être garantis, même après la défaillance d’un élément de suspension ou d’ancrage.\n2 Dans le cas de l’al. 1, les chaînes d’isolateurs doivent être fixées au minimum en deux points séparés sur les supports.\n3 En cas de rupture d’un élément, les éléments restants d’une suspension multiple ou d’un ancrage multiple doivent supporter les efforts dynamiques exercés.\n4 Les chaînes d’isolateurs de telles suspensions multiples doivent comprendre au maximum trois isolateurs lorsque la longueur de chaque isolateur n’atteint pas 0,5 m."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-51.it.json","api_md":"/api/v1/ch/lev/art-51.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_51","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-51","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_51","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-51","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-51/it/","kennung":"ch/lev/art-51","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 51","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"6191e958c4d0e5b92c479b47ebd2bece2c9507ed865adde9ab9f5c0be92dc07d","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-51","titel":"Isolatori a catena multipla","typ":"stelle","url":"/ch/lev/art-51/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Qualora vengano richiesti, quale misura protettiva supplementare, attacchi a sospensione multipla o amarraggi multipli dei conduttori, i fattori di sicurezza secondo l’articolo 50 devono essere garantiti anche in caso di rottura di una delle sospensioni o di uno degli amaraggi parziali.\n2 Le catene di isolatori devono, in tal caso, essere fissate ai sostegni almeno in due punti diversi.\n3 Se una sospensione parziale cede, gli elementi restanti della sospensione multipla o dell’amaraggio multiplo devono resistere alle sollecitazioni di natura dinamica che ne conseguono.\n4 Le singole catene di isolatori di una tale sospensione multipla non devono essere composte da più di tre isolatori quando la lunghezza dei singoli isolatori è inferiore a 0,5 m."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-52.de.json","api_md":"/api/v1/ch/lev/art-52.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_52","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-52","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_52","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-52","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-52/de/","kennung":"ch/lev/art-52","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 52","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"ac4699e5d5facc618ee97e5d5409842db3a54570d2a452c3ae7201246c355a93","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-52","titel":"Armaturen","typ":"stelle","url":"/ch/lev/art-52/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Armaturen müssen so bemessen sein, dass die Einhaltung der Sicherheitsfaktoren nach Anhang 13 bei der grössten statischen Belastung gewährleistet ist."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-52.fr.json","api_md":"/api/v1/ch/lev/art-52.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_52","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-52","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_52","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-52","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-52/fr/","kennung":"ch/lev/art-52","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 52","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"0d35e72a79bcae1cbd708ac35386dacd5c3a2d969b24a97164f04cd69519af29","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-52","titel":"Armatures","typ":"stelle","url":"/ch/lev/art-52/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les armatures doivent être dimensionnées de façon à résister à la charge statique maximale exercée tout en respectant les coefficients de sécurité prescrits à l’annexe 13."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-52.it.json","api_md":"/api/v1/ch/lev/art-52.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_52","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-52","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_52","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-52","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-52/it/","kennung":"ch/lev/art-52","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 52","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"878dac08490b3a0cb415834c516a7f23f70fdb94abd8760702f4b990f37a410f","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-52","titel":"Morsetterie","typ":"stelle","url":"/ch/lev/art-52/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Le morsetterie devono essere dimensionate in modo da garantire il rispetto dei fattori di sicurezza secondo l’appendice 13 quando sollecitati dal carico statico massimo."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-53.de.json","api_md":"/api/v1/ch/lev/art-53.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_53","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-53","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_53","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-53","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-53/de/","kennung":"ch/lev/art-53","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 53","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"796513ff2866f1d46c7ab12ef68100d203d690494b744bbb7ae64fbfbcd3a0be","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-53","titel":"Materialbeständigkeit","typ":"stelle","url":"/ch/lev/art-53/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Leiter, Luftkabel, Leiterverbindungen, Isolatoren und Armaturen müssen gegen umweltbedingte äussere Einflüsse und gegen elektrochemische Zersetzung beständig sein."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-53.fr.json","api_md":"/api/v1/ch/lev/art-53.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_53","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-53","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_53","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-53","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-53/fr/","kennung":"ch/lev/art-53","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 53","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"b02e790e46c5bb668515c7c9282e7a39c141b378b76496730b6ff625a85102f3","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-53","titel":"Compatibilité du matériel","typ":"stelle","url":"/ch/lev/art-53/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les conducteurs, les câbles aériens, les manchons de jonction des conducteurs, les isolateurs et les armatures doivent résister aux conditions environnantes ainsi qu’à la désagrégation électrochimique."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-53.it.json","api_md":"/api/v1/ch/lev/art-53.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_53","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-53","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_53","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-53","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-53/it/","kennung":"ch/lev/art-53","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 53","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"a98fdef49380297fc366459c82fdfd8198684a106c1e97f42d2836597d5363b8","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-53","titel":"Resistenza dei materiali","typ":"stelle","url":"/ch/lev/art-53/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Conduttori, cavi aerei, giunzioni, isolatori e morsetterie devono resistere agli influssi ambientali esterni ambientali ed alla corrosione elettrochimica."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-54.de.json","api_md":"/api/v1/ch/lev/art-54.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_54","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-54","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_54","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-54","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-54/de/","kennung":"ch/lev/art-54","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 54","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"b47258b63ec3f88543b7311ab0a5e6cc7ba67e4044cbffd53dd7f09287fd026f","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-54","titel":"Belastungsannahmen für Tragwerke und Fundamente","typ":"stelle","url":"/ch/lev/art-54/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Die Tragwerke, ihre Bestandteile und die Fundamente sind aufgrund der Belastungsannahmen in den Anhängen 14 und 15 zu berechnen.\n2 Diese Annahmen gelten sinngemäss auch für spezielle Tragwerkausführungen und für Tragwerke von Freiluftanlagen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-54.fr.json","api_md":"/api/v1/ch/lev/art-54.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_54","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-54","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_54","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-54","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-54/fr/","kennung":"ch/lev/art-54","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 54","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"3c98d969abf9363c42b3a62e5c34dc61ae0c0de50322125de6dec27480643f8a","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-54","titel":"Hypothèses de charge pour les supports et les fondations","typ":"stelle","url":"/ch/lev/art-54/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les hypothèses de charge pour le calcul des supports, leurs éléments et leurs fondations figurent aux annexes 14 et 15.\n2 Ces hypothèses sont valables par analogie pour les supports spéciaux et ceux des postes en plein air."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-54.it.json","api_md":"/api/v1/ch/lev/art-54.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_54","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-54","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_54","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-54","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-54/it/","kennung":"ch/lev/art-54","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 54","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"46683bbf233e39114970ea93f8271cc4b1bbe1ce6d32c24302f9d097e388b20d","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-54","titel":"Ipotesi di carico per sostegni e fondazioni","typ":"stelle","url":"/ch/lev/art-54/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 I sostegni, i loro componenti e le fondazioni devono essere dimensionati in base alle ipotesi di carico di cui alle appendici 14 e 15.\n2 Dette ipotesi si applicano per analogia anche ai sostegni di esecuzione speciale ed ai sostegni degli impianti all’aperto."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-55.de.json","api_md":"/api/v1/ch/lev/art-55.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_55","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-55","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_55","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-55","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-55/de/","kennung":"ch/lev/art-55","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 55","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"a2134cbfd4f57ebc42f4a77c2475fae7e4bcbe68926a8dd87e984ea69c892f69","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-55","titel":"Tragwerkarten","typ":"stelle","url":"/ch/lev/art-55/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Stützmasten sind zulässig für Abspannstrecken bis 2 km, mittlere Spannweiten bis 225 m und Leitungswinkel von 195 bis 205 gon. Sie dürfen nicht mit Abspannketten ausgerüstet werden.\n2 Tragmasten sind zulässig für Abspannstrecken bis 4 km und Leitungswinkel von 180 bis 220 gon. Sie dürfen nicht mit Abspannketten ausgerüstet werden. Die Kontrollstelle kann Ausnahmen bewilligen.\n3 Sondertragmasten sind erforderlich für Abspannstrecken über 4 km. Sie sind zulässig für Leitungswinkel von 180 bis 220 gon.\n4 Abspannmasten sind erforderlich bei Leitungswinkeln unter 180 und über 220 gon sowie bei grossen Spannweitenunterschieden oder zur Begrenzung der Abspannstrecken.\n5 Endmasten sind erforderlich beim Übergang von Frei- auf Kabelleitungen oder beim Eintritt einer Freileitung in eine Anlage, sofern nicht ein Anlageteil die Aufgabe eines Endmastes übernimmt."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-55.fr.json","api_md":"/api/v1/ch/lev/art-55.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_55","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-55","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_55","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-55","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-55/fr/","kennung":"ch/lev/art-55","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 55","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"154c2a757d7b804f4210790afe3f910a58f58eafad631adc2a36b78e8708d3d0","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-55","titel":"Types de supports","typ":"stelle","url":"/ch/lev/art-55/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les supports d’appui sont admis pour les longueurs de cantons de pose allant jusqu’à 2 km, pour des portées moyennes allant jusqu’à 225 m et des angles de lignes compris entre 195 et 205 gr. Ils ne doivent pas être équipés de chaînes d’ancrage.\n2 Les supports ordinaires (porteurs) sont admis pour des longueurs de cantons de pose allant jusqu’à 4 km et pour des angles de lignes compris entre 180 et 220 gr. Ils ne doivent pas être équipés de chaînes d’ancrage. L’organe de contrôle peut autoriser des exceptions.\n3 On utilisera des supports porteurs spéciaux pour des longueurs de cantons de pose supérieures à 4 km. Ils sont admis pour des angles de lignes compris entre 180 et 220 gr.\n4 On utilisera des supports tenseurs pour des angles de lignes inférieurs à 180 et supérieurs à 220 gr ainsi que pour de grandes différences de portée et pour limiter la longueur des cantons de pose.\n5 On utilisera des supports terminaux au point de transition entre lignes aériennes et lignes en câbles ou à l’entrée d’une ligne aérienne dans un poste, sauf si la charpente du poste remplace un support terminal."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-55.it.json","api_md":"/api/v1/ch/lev/art-55.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_55","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-55","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_55","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-55","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-55/it/","kennung":"ch/lev/art-55","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 55","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"2199725aa18009c23364963e70cabfa19064228febe6ca83d634e4fe02f24e78","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-55","titel":"Tipi di sostegni","typ":"stelle","url":"/ch/lev/art-55/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 I sostegni ordinari sono ammessi per le tratte di amaraggio fino a 2 km, per campate medie fino a 225 m ed angoli di slineamento compresi tra 195 e 205 gon. Essi non devono mai essere dotati di catene di isolatori disposte in amarro.\n2 I sostegni portanti sono ammessi per le tratte di amaraggio fino a 4 km ed angoli di slineamento compresi tra 180 e 220 gon. Essi non devono essere dotati di catene di isolatori disposte in amarro. L’organo di controllo può autorizzare deroghe.\n3 I sostegni portanti speciali sono necessari per le tratte di amarraggio superiori a 4 km. Essi sono ammessi per angoli di slineamento compresi tra 180 e 220 gon.\n4 I sostegni di amarraggio sono necessari per angoli di slineamento inferiori a 180 gon e superiori a 220 gon, o quando le differenze tra le portate sono grandi oppure per limitare le tratte di amarraggio.\n5 I sostegni terminali sono necessari quando si passa dalla linea aerea alla linea in cavo oppure quando la linea aerea penetra in un impianto, a meno che il compito del sostegno terminale venga assunto da un elemento dell’impianto."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-56.de.json","api_md":"/api/v1/ch/lev/art-56.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_56","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-56","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_56","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-56","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-56/de/","kennung":"ch/lev/art-56","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 56","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"5a45fe9d0cfed3033e525cc6f1f6778f22cc05079c09cb3f8da7f1d345b9b6b5","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-56","titel":"Tragfähigkeit und Standfestigkeit von Tragwerken, Fundamenten, Verstrebungen und Verankerungen","typ":"stelle","url":"/ch/lev/art-56/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Tragwerke, Fundamente, Verstrebungen, Verankerungen und deren Bestandteile sind so zu dimensionieren und zu konstruieren, dass sie den grössten Belastungen standhalten.\n2 Als Werkstoffe sind für Tragwerke Stahl, Stahlbeton oder Holz zu verwenden. Tragwerke aus solchen Werkstoffen sind nach Anhang 13 zu dimensionieren.\n3 Andere Werkstoffe oder unübliche Konstruktionen dürfen nur verwendet werden, wenn ihre Eignung, insbesondere hinsichtlich Festigkeit und Dauerhaftigkeit, nachgewiesen wird. Die Kontrollstelle kann Prüfatteste von anerkannten Prüfstellen oder besondere Prüfungen verlangen.\n4 Der Nachweis genügender Tragfähigkeit kann rechnerisch oder, im Einvernehmen mit der Kontrollstelle, durch Belastungsprüfungen am fertigen Tragwerk erbracht werden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-56.fr.json","api_md":"/api/v1/ch/lev/art-56.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_56","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-56","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_56","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-56","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-56/fr/","kennung":"ch/lev/art-56","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 56","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"8e1ddb11f5386d46f8b8e8c97b1c3b2726ccc0c5eed9e39d2c44124c7722b197","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-56","titel":"Résistance et stabilité des supports et des fondations, des contrefiches et des haubans","typ":"stelle","url":"/ch/lev/art-56/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les supports, les fondations, les contrefiches, les haubans et leurs éléments constitutifs doivent être dimensionnés et construits de façon à résister aux plus fortes sollicitations prévisibles.\n2 Les matériaux généralement utilisés pour les supports sont l’acier, le béton armé ou le bois. Les supports utilisant ces matériaux sont à dimensionner conformément aux données de l’annexe 13.\n3 D’autres matériaux ou des constructions non usuelles ne peuvent être employés que si leur aptitude, en particulier leur résistance mécanique et leur durabilité, est prouvée. L’organe de contrôle peut exiger un certificat d’essais d’une station d’essais reconnue ou ordonner l’exécution d’essais particuliers.\n4 La preuve d’une résistance suffisante peut être fournie par le calcul ou, en accord avec l’organe de contrôle, par des essais de charge effectués sur la structure montée."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-56.it.json","api_md":"/api/v1/ch/lev/art-56.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_56","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-56","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_56","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-56","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-56/it/","kennung":"ch/lev/art-56","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 56","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"c916bc569a276052b073c53abcbd3e1df826d3428c55535b4c62f9c941e99fbd","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-56","titel":"Solidità e stabilità di sostegni, fondazioni, contropali e tiranti e ancoraggi","typ":"stelle","url":"/ch/lev/art-56/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Sostegni, fondazioni, contropali e tiranti, ancoraggi e loro componenti devono essere dimensionati e costruiti in modo da resistere alle sollecitazioni massime.\n2 I materiali impiegati per i sostegni sono l’acciaio, il cemento armato o il legno. I sostegni costituiti dai suddetti materiali devono essere dimensionati conformemente all’appendice 13.\n3 Altri materiali o costruzioni inabituali, possono essere impiegati soltanto se ne è dimostrata l’idoneità, in particolare per quanto concerne la stabilità e la durata. L’organo di controllo può esigere attestati di prova rilasciati da laboratori di prova riconosciuti oppure l’esecuzione di prove speciali.\n4 La dimostrazione di una sufficiente stabilità può essere analitica oppure, d’intesa con l’organo di controllo, ottenuta mediante prove di carico sull’opera finita."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-57.de.json","api_md":"/api/v1/ch/lev/art-57.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_57","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-57","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_57","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-57","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-57/de/","kennung":"ch/lev/art-57","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 57","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"7e35c76f02be6444beacd26d2dec972d93f06516ee02539a925e683df51a2fee","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-57","titel":"Holztragwerke für Regelleitungen","typ":"stelle","url":"/ch/lev/art-57/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Holzmasten müssen mindestens mit einem Zehntel ihrer Länge plus 40 cm ins Erdreich eingelassen werden.\n2 Holzmasten, die in den Boden einbetoniert werden, sind spätestens nach drei Jahren wieder zu entfernen.\n3 Stützmasten sind nach Anhang 16 zu dimensionieren."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-57.fr.json","api_md":"/api/v1/ch/lev/art-57.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_57","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-57","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_57","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-57","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-57/fr/","kennung":"ch/lev/art-57","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 57","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"913a919f82eea2a97e053e2438166ef06a43e035aaf2def51468e3c460cff693","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-57","titel":"Supports en bois pour lignes ordinaires","typ":"stelle","url":"/ch/lev/art-57/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 La profondeur d’implantation dans le sol des poteaux en bois doit être au minimum égale au dixième de leur longueur plus 40 cm.\n2 Les poteaux en bois encastrés dans des massifs en béton doivent être démontrés après trois ans au plus tard.\n3 Les poteaux d’appui en bois pour les lignes ordinaires doivent être dimensionnés conformément aux données de l’annexe 16."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-57.it.json","api_md":"/api/v1/ch/lev/art-57.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_57","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-57","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_57","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-57","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-57/it/","kennung":"ch/lev/art-57","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 57","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"7139d42694e60f984d5ba24637d4f1540650f7a9a55e2849c71464eac0748a4f","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-57","titel":"Sostegni di legno per linee ordinarie","typ":"stelle","url":"/ch/lev/art-57/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 I pali di legno devono essere infissi nel terreno per una profondità pari ad almeno un decimo della loro lunghezza + 40 cm.\n2 I pali di legno cementati direttamente nel terreno devono essere rimossi dopo un periodo di tempo non superiore a tre anni.\n3 I sostegni ordinari devono essere dimensionati secondo l’appendice 16."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-58.de.json","api_md":"/api/v1/ch/lev/art-58.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_58","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-58","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_58","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-58","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-58/de/","kennung":"ch/lev/art-58","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 58","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"135bff3f6bfc40be6be92835558bc6379175ab423fd04513b30885a606794185","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-58","titel":"Verankerungen, Dachständer","typ":"stelle","url":"/ch/lev/art-58/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Stahldrahtseile für Verankerungen müssen einen Mindestquerschnitt von 50 mm2 aufweisen. Im Erdboden ist für Rundstahl ein Mindestdurchmesser von 10 mm, bei Stahldrahtseilen ein Mindestquerschnitt von 70 mm2 erforderlich.\n2 Verankerungen müssen jederzeit nachgespannt werden können.\n3 In elektrisch leitende Verankerungen von isolierenden Tragwerken muss mindestens 1 m unterhalb des tiefsten spannungsführenden Teiles ein Isolierstück eingebaut werden, das der höchsten Nennspannung der Leitung entspricht. Diese Verankerungen dürfen nach dem Befestigungspunkt keine Tragwerkteile mehr berühren.\n4 Dachständer sind gegen Korrosion zu schützen und so zu bemessen, dass die Sicherheitsfaktoren nach Anhang 13 bei der grössten statischen Belastung gewährleistet sind."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-58.fr.json","api_md":"/api/v1/ch/lev/art-58.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_58","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-58","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_58","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-58","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-58/fr/","kennung":"ch/lev/art-58","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 58","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"a90234be70ef651adbbc7df56dd278f782ef683cb7bc6b18348511f514645152","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-58","titel":"Haubans, potelets sur toiture","typ":"stelle","url":"/ch/lev/art-58/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 La section des câbles en acier des haubans doit être d’au moins 50 mm2. Dans le sol, une tringle d’acier rond doit avoir un diamètre d’au moins 10 mm; un câble d’acier, une section d’au moins 70 mm2.\n2 Les haubans doivent être munis de tendeurs afin de permettre en tout temps un réglage ultérieur.\n3 Dans les haubans électriquement conducteurs des supports isolants, on intercalera une pièce isolante d’une tenue diélectrique correspondant à la tension nominale maximale de la ligne et qu’on placera à 1 m au moins au-dessous de la partie sous tension la plus basse. Ces haubans doivent être libres de tout contact mécanique avec les éléments du support.\n4 Les potelets sur toiture doivent être protégés de la corrosion et dimensionnés de façon à résister aux charges statiques maximales exercées tout en respectant les coefficients de sécurité prescrits à l’annexe 13."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-58.it.json","api_md":"/api/v1/ch/lev/art-58.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_58","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-58","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_58","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-58","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-58/it/","kennung":"ch/lev/art-58","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 58","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"d8874269f426a37d7de92fcc5b2c7b28303f03439b2aa65db524bc9b9cc37406","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-58","titel":"Ancoraggi (tiranti), paline","typ":"stelle","url":"/ch/lev/art-58/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 I fili di acciaio degli ancoraggi devono avere una sezione non inferiore a 50 mm2. Nel terreno, i fili d’acciaio a sezione circolare devono avere un diametro minimo pari a 10 mm, mentre per le corde d’acciaio è necessaria una sezione minima pari a 70 mm2.\n2 La tesatura degli ancoraggi deve poter essere rafforzata in qualsiasi momento.\n3 Negli ancoraggi di materiale elettricamente conduttore di sostegni isolanti deve essere intercalato un pezzo isolante, posto ad almeno 1 m sotto la parte più bassa in tensione e commisurato alla tensione nominale più elevata della linea. Dopo il punto di fissaggio, questi ancoraggi non devono più toccare parti del sostegno.\n4 Le paline devono essere protette contro la corrosione e dimensionate in modo da poter garantire il rispetto dei fattori di sicurezza secondo l’appendice 13 quando sollecitate dal carico statico massimo."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-59.de.json","api_md":"/api/v1/ch/lev/art-59.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_59","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-59","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_59","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-59","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-59/de/","kennung":"ch/lev/art-59","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 59","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"b896d780b36e22814f132b7b7ad222b47bbab8f82a6ed715470e748462ccb272","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-59","titel":"Schutz der Tragwerke","typ":"stelle","url":"/ch/lev/art-59/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Tragwerke, Fundamente, Verstrebungen und Verankerungen müssen gegen äussere Einflüsse so geschützt werden, dass Standfestigkeit und Tragfähigkeit dauernd gewährleistet sind.\n2 Tragwerke und Tragwerkteile aus Holz müssen imprägniert oder auf gleichwertige Weise geschützt sein.\n3 Schnittstellen bei Holztragwerken sind so abzudecken oder so anzuordnen, dass sich kein Wasser ansammeln kann."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-59.fr.json","api_md":"/api/v1/ch/lev/art-59.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_59","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-59","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_59","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-59","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-59/fr/","kennung":"ch/lev/art-59","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 59","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"4994f48d7a2c05171e7d9163fb9554d32fae4dd5a78ecaa33d0aace03fcb1f36","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-59","titel":"Protection des supports","typ":"stelle","url":"/ch/lev/art-59/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les supports, les fondations, les contrefiches et les haubans doivent être protégés contre les influences extérieures, afin que soit garanties en permanence leur stabilité et leur résistance.\n2 Les supports et les parties de supports en bois doivent être imprégnés ou protégés de façon similaire.\n3 Les points de jonction de supports en bois doivent être couverts ou disposés de façon à exclure la stagnation d’eau."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-59.it.json","api_md":"/api/v1/ch/lev/art-59.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_59","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-59","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_59","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-59","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-59/it/","kennung":"ch/lev/art-59","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 59","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"775f2a473aeccfb3b016d4e349f19cca278b5ae6c60b719ea4aac802ed723c9a","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-59","titel":"Protezione dei sostegni","typ":"stelle","url":"/ch/lev/art-59/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Tutti i sostegni, le fondazioni, i contropali e tiranti e gli ancoraggi devono essere protetti dagli influssi esterni in modo tale da garantire in ogni momento la stabilità e la solidità necessarie.\n2 I sostegni di legno ed i componenti di legno dei sostegni devono essere impregnati o protetti in modo equivalente.\n3 I giunti dei sostegni di legno devono essere disposti e protetti in modo da evitare i ristagni d’acqua."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-60.de.json","api_md":"/api/v1/ch/lev/art-60.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_60","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-60","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_60","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-60","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-60/de/","kennung":"ch/lev/art-60","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 60","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"10d222e987321424ba3ec9c0e89ed19bf1dbc114e3c09c13640efba3009b71d7","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-60","titel":"Kennzeichnung der Tragwerke","typ":"stelle","url":"/ch/lev/art-60/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Tragwerke müssen die Initialen des Leitungsinhabers tragen sowie mit einer Ordnungsnummer und mit der Jahreszahl der Aufstellung versehen sein (Hinweistafel).\n2 Holzmasten sind 4,5 m über dem Fussende mit der Jahreszahl der Imprägnierung und dem Kennzeichen des Lieferanten dauerhaft zu markieren.\n3 An den Tragwerken von Hochspannungsfreileitungen sowie an Dachständern und bei Fassadenabspannungen von Leitungen mit blanken Leitern sind Warnzeichen anzubringen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-60.fr.json","api_md":"/api/v1/ch/lev/art-60.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_60","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-60","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_60","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-60","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-60/fr/","kennung":"ch/lev/art-60","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 60","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"7fc1414c94310f770b2bce7654743c9c520cbeaede850df95540270d538487e8","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-60","titel":"Indications figurant sur les supports","typ":"stelle","url":"/ch/lev/art-60/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les supports doivent être munis d’une plaquette indicatrice mentionnant un numéro d’ordre, l’année de la pose, et les initiales du propriétaire de la ligne.\n2 Les poteaux en bois doivent en outre porter à 4,5 m au-dessus du pied, en caractères indélébiles, l’année de l’imprégnation et l’identification du fournisseur.\n3 Un panneau avertisseur du danger encouru doit être apposé sur les supports de lignes aériennes à haute tension ainsi que sur les potelets sur toiture et les ancrages de façade des lignes à conducteurs nus."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-60.it.json","api_md":"/api/v1/ch/lev/art-60.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_60","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-60","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_60","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-60","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-60/it/","kennung":"ch/lev/art-60","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 60","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"5481dfa88f55b850c7c0bb8493fd881217ddd6f29c85702ba204646149b74a40","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-60","titel":"Identificazione dei sostegni","typ":"stelle","url":"/ch/lev/art-60/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 I sostegni devono essere provvisti di un numero d’ordine, dell’anno di costruzione e delle iniziali dell’esercente della linea (targa indicatrice).\n2 Sui sostegni di legno vanno inoltre marcati indelebilmente, ad una altezza di 4,5 dal piede, l’anno di impregnazione e la designazione del fornitore.\n3 Sui sostegni delle linee aeree ad alta tensione, sulle paline e presso gli ancoraggi alle facciate delle linee con conduttori nudi devono essere apposti cartelli monitori."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-61.de.json","api_md":"/api/v1/ch/lev/art-61.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_61","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-61","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_61","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-61","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-61/de/","kennung":"ch/lev/art-61","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 61","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"ec5f93827641a66a831605f97c0a661600b11c401e6c5e34989e45fb2dc20d3c","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-61","titel":"Tragwerkfundamente","typ":"stelle","url":"/ch/lev/art-61/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Tragwerkfundamente müssen so erstellt werden, dass bei den grössten Belastungen die Standsicherheit des Tragwerkes gewährleistet ist und keine unzulässige Schiefstellung auftritt.\n2 Die Sicherheit gegen Umsturz muss mindestens 1,5 sein.\n3 Bei der Berechnung der Fundamente sind neben den Bodenbedingungen auch Randbedingungen wie Grundwasser, häufige Hochwasser, Böschungen und ähnliche Einflüsse zu berücksichtigen.\n4 Die Boden- und die Randbedingungen müssen an Ort und Stelle überprüft werden.\n5 Für Sondertragmasten sowie für Tragwerke aus Holz bei Weitspannleitungen, die länger als drei Jahre bestehen bleiben, sind besondere Fundamente oder Sockel zu erstellen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-61.fr.json","api_md":"/api/v1/ch/lev/art-61.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_61","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-61","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_61","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-61","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-61/fr/","kennung":"ch/lev/art-61","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 61","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"f0ad6f4ea53702136999c1df8d0cc7a2f20ffe0b1b13845174ad9dc87ffa918f","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-61","titel":"Fondations des supports","typ":"stelle","url":"/ch/lev/art-61/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les fondations des supports doivent être réalisées de façon à en assurer la stabilité et à éviter toute inclinaison accidentelle des supports sous charge maximale.\n2 Le coefficient de sécurité au renversement doit être au minimum de 1,5.\n3 Pour dimensionner les fondations, on considérera outre les facteurs locaux du sol, les facteurs limitrophes tels que la nappe phréatique, les hautes eaux, les talus, etc.\n4 Les valeurs géotechniques et les facteurs limitrophes doivent être vérifiés sur le site.\n5 Des fondations ou des socles spécialement adaptés sont requis pour les supports spéciaux ainsi que pour les poteaux en bois utilisés pour les lignes à grandes portées qui doivent rester en place plus de trois ans."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-61.it.json","api_md":"/api/v1/ch/lev/art-61.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_61","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-61","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_61","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_1_a","num":"1a. Kapitel:","titel":"Freileitungen"},{"ebene":"section","eid":"tit_2/chap_1_a/sec_2","num":"2. Abschnitt:","titel":"Starkstromfreileitungen"}],"id":"ch/lev/art-61","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-61/it/","kennung":"ch/lev/art-61","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 61","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"db5330e9a9ff26cbafed675f8661bebcb3bc5d940792df1bbb03f88644a16ae4","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-61","titel":"Fondazioni dei sostegni","typ":"stelle","url":"/ch/lev/art-61/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le fondazioni dei sostegni devono essere eseguite in modo che la stabilità dei sostegni in presenza delle sollecitazioni massime sia garantita e che non si producano inclinazioni inammissibili.\n2 La sicurezza al rovesciamento deve essere almeno pari ad 1,5.\n3 Nel calcolo delle fondazioni occorre tener presenti, oltre alle caratteristiche locali del terreno, anche le condizioni marginali quali la presenza di acque sotterranee, la frequenza delle piene, le scarpate ed altri influssi.\n4 Le condizioni del terreno e le condizioni marginali devono essere verificate sul posto.\n5 I sostegni portanti speciali o i sostegni di legno per linee a grande portata, destinati a restare per un periodo superiore a tre anni, necessitano di fondazioni o zoccoli speciali."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-62.de.json","api_md":"/api/v1/ch/lev/art-62.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_62","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-62","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_62","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-62","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-62/de/","kennung":"ch/lev/art-62","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 62","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"76a808bcd6c4cf54a26825ed6a492b05fe0e0b5a1722a0438e07f4bd05adb048","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-62","titel":"Werkpläne","typ":"stelle","url":"/ch/lev/art-62/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Die Betriebsinhaber müssen Lage und Verlegungsart ihrer Kabelleitungen festhalten. Die Leitungen müssen jederzeit geortet werden können.\n2 Die entsprechenden Unterlagen sind bis zur Entfernung der Leitung aufzubewahren. Dies gilt auch für Leitungen, die nicht mehr benützt werden.\n3 Die Betriebsinhaber geben auf Anfrage berechtigten Personen Lage und Verlegungsart ihrer Kabelleitungen bekannt."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-62.fr.json","api_md":"/api/v1/ch/lev/art-62.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_62","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-62","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_62","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-62","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-62/fr/","kennung":"ch/lev/art-62","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 62","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"9ff04c76b024d168e6bcf8790ba5e5f6cbeb7180faddd259c62685b2176c0b6f","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-62","titel":"Plans de l’ouvrage","typ":"stelle","url":"/ch/lev/art-62/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les exploitants doivent enregistrer le tracé et le genre de pose des lignes en câbles de façon à pouvoir les repérer en tout temps.\n2 Les documents concernant les lignes en câbles doivent être conservés jusqu’au moment de l’élimination des lignes. Ceci est également valable pour les lignes qui ne sont plus exploitées.\n3 Sur demande, les exploitants indiquent à des tiers autorisés la situation et le genre de pose de leurs lignes en câbles."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-62.it.json","api_md":"/api/v1/ch/lev/art-62.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_62","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-62","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_62","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-62","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-62/it/","kennung":"ch/lev/art-62","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 62","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"4ededa4866b234bccacfc58f7c7653fca6aa84fa93a49ec40c41350ff7719af1","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-62","titel":"Piani d’opera","typ":"stelle","url":"/ch/lev/art-62/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Gli esercenti devono registrare la posizione e le modalità di posa delle loro linee in cavo. Le linee devono poter essere localizzate in qualsiasi momento.\n2 La documentazione relativa alle linee in cavo deve essere conservata fino alla loro eliminazione. Questo vale anche per le linee non più utilizzate.\n3 Su richiesta di terzi legittimati, gli esercenti rendono note la posizione e le modalità di posa delle linee in cavo."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-63.de.json","api_md":"/api/v1/ch/lev/art-63.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_63","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-63","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_63","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-63","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-63/de/","kennung":"ch/lev/art-63","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 63","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"0becb1a307bde0cfb4774161cdc3a6e22e0a2dd91feb9f35210fbcb2f05887b5","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-63","titel":"Zugänglichkeit","typ":"stelle","url":"/ch/lev/art-63/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Alle Teile von Kabelleitungen, die inspiziert oder gewartet werden müssen, müssen für das Betriebspersonal jederzeit zugänglich sein. Die für Arbeiten erforderliche Bewegungsfreiheit und die Sicherheit für das Personal müssen gewährleistet sein.\n2 Kabelzubehöre dürfen die Zugänglichkeit zu den Anlagen nicht beeinträchtigen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-63.fr.json","api_md":"/api/v1/ch/lev/art-63.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_63","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-63","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_63","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-63","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-63/fr/","kennung":"ch/lev/art-63","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 63","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"870680dda475499f5ec3a167f9b250b940415a9cfb4717db2be5808f14c69964","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-63","titel":"Accessibilité","typ":"stelle","url":"/ch/lev/art-63/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Toutes les parties de lignes en câbles nécessitant une inspection ou un entretien régulier doivent être accessibles en permanence au personnel de service. La liberté de mouvement nécessaire pour l’exécution des travaux et la sécurité du personnel doivent être garanties.\n2 Les accessoires de câbles ne doivent pas gêner l’accès aux installations."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-63.it.json","api_md":"/api/v1/ch/lev/art-63.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_63","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-63","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_63","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-63","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-63/it/","kennung":"ch/lev/art-63","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 63","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"f49d82361b8c9ee9e1896d2813052f7d46d73038a783b542c0abe0499a90ab13","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-63","titel":"Accessibilità","typ":"stelle","url":"/ch/lev/art-63/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Tutte le parti delle linee in cavo che devono essere ispezionate o sottoposte a manutenzione devono essere accessibili in qualsiasi momento al personale di servizio. Devono essere garantite la necessaria libertà di movimento per l’esecuzione dei lavori e la sicurezza del personale.\n2 Gli accessori dei cavi devono essere disposti in modo da non ostacolare l’accesso agli impianti."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-64.de.json","api_md":"/api/v1/ch/lev/art-64.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_64","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-64","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_64","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-64","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-64/de/","kennung":"ch/lev/art-64","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 64","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"242cb3b71debb2fcf3d02d53f9b82fd26c2d1a4b6c0809d5dd8ded765e45d503","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-64","titel":"Sicherung freigelegter Leitungsabschnitte","typ":"stelle","url":"/ch/lev/art-64/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Freigelegte Leitungsabschnitte sind durch den Betriebsinhaber zu identifizieren und soweit nötig zu schützen.\n2 Die Gefährdung Dritter ist durch Schutzmassnahmen zu verhindern."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-64.fr.json","api_md":"/api/v1/ch/lev/art-64.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_64","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-64","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_64","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-64","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-64/fr/","kennung":"ch/lev/art-64","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 64","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"d882a1819875c4f30baa6118c150414037ab0e9e9113e258ec610c1542ce576c","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-64","titel":"Sécurité des tronçons de ligne dans les fouilles à ciel ouvert","typ":"stelle","url":"/ch/lev/art-64/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les tronçons de ligne dans les fouilles à ciel ouvert doivent être identifiés par l’exploitant et protégés en fonction des nécessités.\n2 Des mesures de protection appropriées doivent être prises pour éviter que des tiers soient mis en danger."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-64.it.json","api_md":"/api/v1/ch/lev/art-64.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_64","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-64","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_64","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-64","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-64/it/","kennung":"ch/lev/art-64","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 64","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"5246f3493f2459d15371254eca042fd5dcad82004c7050ce1a8da85cdcdb82b7","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-64","titel":"Protezione delle tratte di linea allo scoperto","typ":"stelle","url":"/ch/lev/art-64/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 L’esercente deve identificare e, se necessario, proteggere le tratte di linea allo scoperto.\n2 Grazie a misure idonee di protezione, va impedita l’esposizione a pericolo di terzi."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-65.de.json","api_md":"/api/v1/ch/lev/art-65.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_65","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-65","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_65","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-65","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-65/de/","kennung":"ch/lev/art-65","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 65","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"26c92ed622e3436f20b956416fbdf24454aded65fd8c3cbed27b0aee490bfe67","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-65","titel":"Allgemeine technische Anforderungen","typ":"stelle","url":"/ch/lev/art-65/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Kabelanlagen müssen während der Erstellung und dem Betrieb den mechanischen, chemischen, thermischen, elektrischen und umweltbedingten Beanspruchungen standhalten.\n2 Alle Teile einer Kabelleitung müssen auf den Betrieb und unter sich abgestimmt sein.\n3 Kabelträger müssen den mechanischen Beanspruchungen standhalten, die sich im normalen Betrieb und in voraussehbaren Störfällen ergeben."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-65.fr.json","api_md":"/api/v1/ch/lev/art-65.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_65","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-65","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_65","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-65","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-65/fr/","kennung":"ch/lev/art-65","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 65","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"ba6f01d303c5899555e18ee5851a39429af6005ff4f37ea2b7c6247233c6d590","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-65","titel":"Exigences techniques générales","typ":"stelle","url":"/ch/lev/art-65/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les installations de câbles doivent résister aux contraintes mécaniques, chimiques, thermiques, électriques et environnementales, tant pendant leur construction que pendant leur exploitation.\n2 Tous les composants d’une ligne en câbles doivent être adaptés aux conditions d’exploitation et être coordonnés entre eux.\n3 Les porte-câbles doivent résister aux contraintes mécaniques exercées en exploitation normale et en cas de perturbations prévisibles."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-65.it.json","api_md":"/api/v1/ch/lev/art-65.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_65","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-65","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_65","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-65","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-65/it/","kennung":"ch/lev/art-65","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 65","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"a6f68f444244d43fe7dc20bf615c6a08936ad810a12ee6139000decbcfdfdb88","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-65","titel":"Esigenze tecniche di carattere generale","typ":"stelle","url":"/ch/lev/art-65/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Nella fase di costruzione e durante l’esercizio dell’impianto, le installazioni di cavi devono resistere alle sollecitazioni meccaniche, chimiche, termiche, elettriche e ambientali.\n2 Tutte le parti di una linea in cavo devono rispondere alle condizioni d’esercizio ed essere armonizzate tra loro.\n3 Gli elementi portanti dei cavi devono far fronte alle sollecitazioni meccaniche risultanti in condizioni normali d’esercizio e in seguito a guasti prevedibili."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-66.de.json","api_md":"/api/v1/ch/lev/art-66.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_66","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-66","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_66","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-66","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-66/de/","kennung":"ch/lev/art-66","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 66","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"878ec9e2cdee6977b198462e1c041b9c10f979261f42e64bc496edd76557b517","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-66","titel":"Kennzeichnung","typ":"stelle","url":"/ch/lev/art-66/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Kabel müssen an den Enden sowie an zugänglichen Stellen eindeutig, dauerhaft und gut sichtbar gekennzeichnet sein."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-66.fr.json","api_md":"/api/v1/ch/lev/art-66.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_66","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-66","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_66","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-66","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-66/fr/","kennung":"ch/lev/art-66","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 66","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"6ac9674553ac1827cb013fd2727ff5b004c601d7694129233134e8cdae9ee4b2","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-66","titel":"Indications figurant sur les câbles","typ":"stelle","url":"/ch/lev/art-66/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les câbles doivent être identifiés de façon univoque, durable et bien lisible à leurs extrémités ainsi qu’aux emplacements accessibles."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-66.it.json","api_md":"/api/v1/ch/lev/art-66.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_66","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-66","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_66","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-66","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-66/it/","kennung":"ch/lev/art-66","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 66","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"900d35c4070d4bce6d8e55d9644b34f0c890a8889aa3ef904a6dbb17037219ce","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-66","titel":"Identificazione","typ":"stelle","url":"/ch/lev/art-66/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Ai terminali e nei luoghi accessibili, i cavi devono essere identificati in modo inequivocabile, indelebile e ben visibile."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-67.de.json","api_md":"/api/v1/ch/lev/art-67.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_67","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-67","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_67","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-67","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-67/de/","kennung":"ch/lev/art-67","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 67","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"af6c13eefe61063212fb99b1d00866baee3b111796ade80cce3369f34adc98d0","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-67","titel":"Verlegung von Kabelleitungen","typ":"stelle","url":"/ch/lev/art-67/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Kabelleitungen sind so zu verlegen, dass sie im normalen Betrieb vor Beschädigungen geschützt sind.\n2 Hochspannungskabel sind nach Möglichkeit von Niederspannungskabeln sowie Steuer- und Schwachstromkabeln getrennt zu verlegen.\n3 Für Luftkabel gelten die Bestimmungen über die Freileitungen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-67.fr.json","api_md":"/api/v1/ch/lev/art-67.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_67","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-67","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_67","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-67","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-67/fr/","kennung":"ch/lev/art-67","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 67","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"4a4feef666e1e8f181d237ce927ee451e29ebf58940cbf4005739e75070c3497","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-67","titel":"Pose des lignes en câbles","typ":"stelle","url":"/ch/lev/art-67/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les lignes en câbles doivent être posées de manière à ne pouvoir être détériorées en exploitation normale.\n2 Les câbles à haute tension doivent être, autant que possible, séparés des câbles à basse tension, des câbles de commande et des câbles à courant faible.\n3 Les prescriptions valables pour les lignes aériennes sont applicables aux câbles aériens."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-67.it.json","api_md":"/api/v1/ch/lev/art-67.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_67","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-67","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_67","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-67","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-67/it/","kennung":"ch/lev/art-67","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 67","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"c44f008628da84ec278115d0258d1b3dcb612aba510527a2e23f4e7f9545fc56","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-67","titel":"Posa delle linee in cavo","typ":"stelle","url":"/ch/lev/art-67/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 I cavi devono essere posati in modo da essere protetti da danneggiamenti in condizioni normali d’esercizio.\n2 Per quanto possibile, i cavi ad alta tensione vanno posati in modo da risultare separati da quelli a bassa tensione e dai cavi di comando ed a corrente debole.\n3 Per i cavi aerei valgono le disposizioni applicabili alle linee aeree."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-68.de.json","api_md":"/api/v1/ch/lev/art-68.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_68","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-68","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_68","fussnoten":[{"marker":"28","nummer":28,"text":"Fassung gemäss Anhang 2 Ziff. 2 der Rohrleitungssicherheitsverordnung vom 4. Juni 2021, in Kraft seit 1. Juli 2021 (AS 2021 348)."},{"marker":"29","nummer":29,"text":"Fassung gemäss Anhang 2 Ziff. 2 der Rohrleitungssicherheitsverordnung vom 4. Juni 2021, in Kraft seit 1. Juli 2021 (AS 2021 348)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-68","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-68/de/","kennung":"ch/lev/art-68","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 68","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"a8389e6d296b3ce9ee95138dc419e8b6a9f081939796c19777da61140e728302","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-68","titel":"Verlegung im Erdreich","typ":"stelle","url":"/ch/lev/art-68/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Kabelleitungen, die direkt im Erdreich verlegt werden, müssen eine mechanische Festigkeit aufweisen, die auf die Art der Bettung abgestimmt ist.\n2 Die Verlegetiefe von Kabelleitungen muss im Erdreich betragen:\na. für Schwachstromkabel mindestens 0,4 m;\nb. für Niederspannungskabel mindestens 0,6 m;\nc. für Hochspannungskabel mindestens 0,8 m.\n3 Können die Verlegetiefen nach Absatz 2 nicht eingehalten werden, sind zusätzliche Schutzmassnahmen, insbesondere gegen mechanische Beschädigungen zu treffen.\n4 Die Kontrollstelle kann Ausnahmen bewilligen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-68.fr.json","api_md":"/api/v1/ch/lev/art-68.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_68","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-68","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_68","fussnoten":[{"marker":"27","nummer":27,"text":"Nouvelle teneur selon l’annexe 2 ch. 2 de l’O du 4 juin 2021 concernant les prescriptions de sécurité pour les installations de transport par conduites, en vigueur depuis le 1er juil. 2021 (RO 2021 348)."},{"marker":"28","nummer":28,"text":"Nouvelle teneur selon l’annexe 2 ch. 2 de l’O du 4 juin 2021 concernant les prescriptions de sécurité pour les installations de transport par conduites, en vigueur depuis le 1er juil. 2021 (RO 2021 348)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-68","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-68/fr/","kennung":"ch/lev/art-68","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 68","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"d14132b9aac4d7376a0746ea28d6ea01fa202d1aa5b33d1c805a7d9713ab5f76","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-68","titel":"Enfouissement","typ":"stelle","url":"/ch/lev/art-68/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Lorsque les lignes en câble sont enfouies directement dans le sol, leur résistance mécanique doit être adaptée à l’aménagement de la fouille.\n2 La profondeur d’enfouissement des lignes en câble doit être au minimum de:\na. 0,4 m pour les câbles à courant faible;\nb. 0,6 m pour les câbles à basse tension;\nc. 0,8 m pour les câbles à haute tension.\n3 Lorsque les profondeurs d’enfouissement prescrites à l’al. 2 ne peuvent pas être respectées, il faut prendre des mesures de protection supplémentaires tout spécialement contre les dommages mécaniques.\n4 L’organe de contrôle peut autoriser des exceptions."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-68.it.json","api_md":"/api/v1/ch/lev/art-68.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_68","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-68","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_68","fussnoten":[{"marker":"29","nummer":29,"text":"Nuovo testo giusta l’all. 2 n. 2 dell’O del 4 giu. 2021 sulla sicurezza degli impianti di trasporto in condotta, in vigore dal 1° lug. 2021 (RU 2021 348)."},{"marker":"30","nummer":30,"text":"Nuovo testo giusta l’all. 2 n. 2 dell’O del 4 giu. 2021 sulla sicurezza degli impianti di trasporto in condotta, in vigore dal 1° lug. 2021 (RU 2021 348)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-68","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-68/it/","kennung":"ch/lev/art-68","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 68","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"fe7c9d6513acf88018665dc9ee83920add14b962b85c39bde100faa2b3c786c6","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-68","titel":"Interramento","typ":"stelle","url":"/ch/lev/art-68/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le linee in cavo direttamente interrate devono presentare una resistenza meccanica adattata alla natura del letto di posa.\n2 La profondità di interramento delle linee in cavo deve essere:\na. almeno pari a 0,4 m per i cavi a corrente debole;\nb. almeno pari a 0,6 m per i cavi a bassa tensione;\nc. almeno pari a 0,8 m per i cavi ad alta tensione.\n3 Laddove le profondità di interramento di cui al capoverso 2 non possono essere rispettate, vanno prese misure protettive supplementari, in particolare contro i danni meccanici.\n4 L’organo di controllo può autorizzare deroghe."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-69.de.json","api_md":"/api/v1/ch/lev/art-69.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_69","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-69","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_69","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-69","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-69/de/","kennung":"ch/lev/art-69","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 69","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"6fd4fafee77d7775697475cf2d9e8e2030c109fc36f996d7d66d3a49f37e8011","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-69","titel":"Verlegung in Kabelschutzrohren","typ":"stelle","url":"/ch/lev/art-69/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Kabelschutzrohre aus Kunststoff müssen die von der Kontrollstelle vorgeschriebenen Eigenschaften aufweisen.\n2 Kabel, Kabelschutzrohre und Kabelrohrblöcke in oder bei Kunstbauten müssen so beschaffen sein, dass sie den zu erwartenden Wärmedehnungen, Erschütterungen usw. standhalten.\n3 Metallene Kabelschutzrohre sind zu erden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-69.fr.json","api_md":"/api/v1/ch/lev/art-69.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_69","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-69","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_69","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-69","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-69/fr/","kennung":"ch/lev/art-69","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 69","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"90cf312a81ba1171932576d3cb74227a0197ba21f2cdfc0f60d7cda96be2bb52","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-69","titel":"Pose dans des tuyaux de protection","typ":"stelle","url":"/ch/lev/art-69/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les tuyaux de protection en matières synthétiques doivent satisfaire aux exigences de qualité prescrites par l’organe de contrôle.\n2 Les câbles, les tuyaux à câbles, les blocs de tuyaux à câbles à l’intérieur des ouvrages d’art et au voisinage de ceux-ci doivent être conçus pour résister sans dommage aux allongements thermiques, aux vibrations, etc. pouvant intervenir.\n3 Les tuyaux de protection métalliques pour câbles doivent être mis à la terre."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-69.it.json","api_md":"/api/v1/ch/lev/art-69.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_69","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-69","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_69","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-69","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-69/it/","kennung":"ch/lev/art-69","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 69","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"db6f47cb7e3067f2c0a5ddd6c8c6c14a5175fe36ae635d92b3e4577c02741a05","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-69","titel":"Posa in tubi di protezione","typ":"stelle","url":"/ch/lev/art-69/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 I tubi di protezione di materiale sintetico devono presentare le caratteristiche prescritte dall’organo di controllo.\n2 Cavi, tubi di protezione e blocchi pluricanali per cavi posati entro o presso opere di genio civile, devono essere costituiti in modo da resistere alle prevedibili dilatazioni termiche, vibrazioni, ecc.\n3 I tubi di protezione metallici devono essere messi a terra."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-70.de.json","api_md":"/api/v1/ch/lev/art-70.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_70","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-70","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_70","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-70","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-70/de/","kennung":"ch/lev/art-70","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 70","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"e859fb23b66d9b5b3be509e7692138097cf20c48f0239c65f58c654bd1d7c4ab","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-70","titel":"Verlegung in Tunnels und Stollen","typ":"stelle","url":"/ch/lev/art-70/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Kabelleitungen in Tunnels und Stollen müssen kontrolliert und instand gehalten werden können.\n2 Tunnels und Stollen müssen ein ungefährliches Arbeiten erlauben. Sie müssen namentlich über eine entsprechende Luftqualität verfügen sowie explosions- und überflutungssicher sein.\n3 Tunnels und Stollen müssen in zwei Richtungen verlassen werden können. Die Fluchtwege sind in Bodennähe gut sichtbar zu bezeichnen.\n4 Dienen Tunnels und Stollen auch anderen Zwecken, so sind die entsprechenden Sicherheitsmassnahmen zu treffen.\n5 Tunnels und Stollen sind in angemessene Brandabschnitte zu unterteilen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-70.fr.json","api_md":"/api/v1/ch/lev/art-70.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_70","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-70","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_70","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-70","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-70/fr/","kennung":"ch/lev/art-70","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 70","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"d9d567ce77530b9b4f75557bbc2b57e2ead68d2567f6201a6ad16be551cebf41","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-70","titel":"Pose dans les galeries et les tunnels","typ":"stelle","url":"/ch/lev/art-70/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les lignes en câbles dans les galeries et les tunnels doivent pouvoir être contrôlées et entretenues en tout temps.\n2 Les galeries et les tunnels doivent être conçus de façon à ce qu’on puisse y travailler sans danger. On portera une attention toute particulière à la qualité de l’air et aux risques d’explosion et d’inondation.\n3 Les galeries et les tunnels doivent pouvoir être évacués aux deux extrémités. Les cheminements de secours sont à indiquer de façon bien lisible à proximité du sol.\n4 Dans les galeries et les tunnels destinés en plus à d’autres usages, on prendra les mesures de sécurité adéquates.\n5 On aménagera des secteurs coupe-feu dans les galeries et les tunnels."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-70.it.json","api_md":"/api/v1/ch/lev/art-70.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_70","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-70","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_70","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-70","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-70/it/","kennung":"ch/lev/art-70","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 70","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"82f9a4752183d921f6b9a1c35ba165c31d3397299d7a327da243681620532168","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-70","titel":"Posa all’interno di gallerie e cunicoli","typ":"stelle","url":"/ch/lev/art-70/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le linee in cavo all’interno di gallerie e di cunicoli devono poter essere controllate e sottoposte a manutenzione regolare.\n2 Le gallerie ed i cunicoli devono permettere uno svolgimento sicuro dei lavori. Devono disporre, in particolare, di una buona qualità dell’aria ed essere protetti contro il pericolo di esplosione e di inondazione.\n3 Le gallerie ed i cunicoli devono poter essere abbandonati nelle due direzioni. I percorsi di fuga devono essere contrassegnati in prossimità del suolo in modo chiaramente visibile.\n4 Nelle gallerie e nei cunicoli destinati anche ad altri usi, vanno adottate le necessarie misure di sicurezza.\n5 Le gallerie ed i cunicoli devono essere suddivise in tronchi di lunghezza idonea mediante mezzi tagliafuoco."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-71.de.json","api_md":"/api/v1/ch/lev/art-71.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_71","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-71","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_71","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-71","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-71/de/","kennung":"ch/lev/art-71","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 71","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"56d3ee9fc30ad86a21b490f8ccf139a2b80caf0aac5c358bcf52e0ef4ee90d79","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-71","titel":"Verlegung in Gewässern","typ":"stelle","url":"/ch/lev/art-71/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Kabelleitungen sind in Gewässern so zu verlegen, dass sie weder durch Geschiebe oder Ablagerungen noch bei Uferauswaschungen beschädigt werden.\n2 In schiffbaren Gewässern sind die Kabel zudem gegen mechanische Einwirkungen der Schifffahrt zu schützen.\n3 An Uferzonen, seichten Stellen sowie in der Nähe von Schiffsanlegeplätzen sind Kabelleitungen für die Schifffahrt deutlich und dauerhaft zu markieren."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-71.fr.json","api_md":"/api/v1/ch/lev/art-71.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_71","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-71","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_71","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-71","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-71/fr/","kennung":"ch/lev/art-71","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 71","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"8ccac897935d163ff07ca88632cf0f6ab79a6631d854620bcde1ec059214dc79","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-71","titel":"Pose dans l’eau","typ":"stelle","url":"/ch/lev/art-71/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les lignes en câbles doivent être posées dans l’eau de manière à ne pouvoir être endommagées ni par des sédiments ou des alluvions ni par l’érosion éventuelle des rives.\n2 Les câbles posés dans les eaux navigables doivent également être protégés contre les effets mécaniques de la navigation.\n3 Sur les rives, en eau peu profonde ainsi qu’à proximité de places d’ancrage de bateaux, les navigateurs doivent pouvoir repérer durablement et sans équivoque les lignes en câbles."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-71.it.json","api_md":"/api/v1/ch/lev/art-71.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_71","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-71","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_71","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-71","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-71/it/","kennung":"ch/lev/art-71","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 71","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"1767a97499dd47b6332adc50fa862d357954fdc2a657cff784b4f11caa98e006","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-71","titel":"Posa in acqua","typ":"stelle","url":"/ch/lev/art-71/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le linee in cavo devono essere posate in acqua in modo da non poter essere danneggiate da detriti o da sedimentazioni oppure dalle erosioni delle rive.\n2 Nelle acque navigabili, i cavi devono essere anche protetti dagli influssi meccanici originati dalla navigazione.\n3 Nelle zone rivierasche, in acque basse e in vicinanza degli approdi dei battelli, le linee in cavo vanno contrassegnate in modo chiaro e indelebile all’intenzione della navigazione."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-72.de.json","api_md":"/api/v1/ch/lev/art-72.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_72","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-72","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_72","fussnoten":[{"marker":"30","nummer":30,"text":"SR 734.1"},{"marker":"31","nummer":31,"text":"SR 734.2"}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-72","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-72/de/","kennung":"ch/lev/art-72","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 72","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"67266768912ce77576e5c8744ae9db2a2368ef10a2053711d5bdd3df910e030f","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-72","titel":"Erdung","typ":"stelle","url":"/ch/lev/art-72/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Die leitende Umhüllung einer Kabelleitung ist an beiden Enden zu erden. Kann aus betrieblichen Gründen ein Ende nicht geerdet werden, so ist dieses gegen direkte Berührung zu schützen und mit Warn- oder Hinweistafeln zu versehen.\n2 Elektrisch leitende Teile wie Kabelarmierungen, Armaturen, Zubehöre sind zu erden.\n3 Die den auftretenden Mantelspannungen entsprechenden Sicherheitsabstände sind bei Kabeln mit einseitig geerdeten oder ausgekreuzt geerdeten Metallmänteln einzuhalten.\n4 Die Erdung von Schwachstromkabelleitungen richtet sich nach den Bestimmungen der Schwachstromverordnung vom 30. März 1994.\n5 Die Erdung von Starkstromkabelleitungen richtet sich nach den Bestimmungen der Starkstromverordnung vom 30. März 1994."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-72.fr.json","api_md":"/api/v1/ch/lev/art-72.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_72","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-72","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_72","fussnoten":[{"marker":"29","nummer":29,"text":"RS 734.1"},{"marker":"30","nummer":30,"text":"RS 734.2"}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-72","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-72/fr/","kennung":"ch/lev/art-72","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 72","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"9853d9e57c72808a25196264e22c00a39c4dd84283be7d7ca11966efad8aec44","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-72","titel":"Mise à la terre","typ":"stelle","url":"/ch/lev/art-72/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 La gaine conductrice d’une ligne en câbles doit être mise à la terre aux deux extrémités. Si des raisons d’exploitation interdisent de le faire à l’une des extrémités, on protégera celle-ci des contacts directs et placera des panneaux d’avertissement ou des panneaux indicateurs.\n2 Les armures de câbles, les armatures, les accessoires et autres éléments conducteurs d’électricité doivent être mis à la terre.\n3 Les distances de sécurité correspondant aux tensions susceptibles d’apparaître sur les gaines doivent être respectées pour les câbles dont les gaines métalliques sont mises à la terre à l’une des extrémités ou aux deux extrémités en croisant les câbles.\n4 La mise à terre des lignes en câbles à courant faible doit correspondre aux dispositions de l’ordonnance du 30 mars 1994 sur le courant faible.\n5 La mise à terre des lignes en câbles à courant fort doit correspondre aux dispositions de l’ordonnance du 30 mars 1994 sur le courant fort."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-72.it.json","api_md":"/api/v1/ch/lev/art-72.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_72","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-72","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_72","fussnoten":[{"marker":"31","nummer":31,"text":"RS 734.1"},{"marker":"32","nummer":32,"text":"RS 734.2"}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-72","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-72/it/","kennung":"ch/lev/art-72","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 72","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"7158210d89e9cb61dddd83de9d2e3c13878be4233451b60dbcb7dc2177ae4a04","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-72","titel":"Messa a terra","typ":"stelle","url":"/ch/lev/art-72/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 L’involucro conduttore di una linea in cavo deve essere messo a terra alle due estremità. Se, per motivi di esercizio, un’estremità non può essere messa a terra, questa deve essere protetta contro il contatto diretto e provvista di cartelli di avvertimento o di segnalazione.\n2 Le parti elettricamente conduttrici, quali armature dei cavi, terminali e accessori, devono essere messi a terra.\n3 Occorre rispettare le distanze di sicurezza imposte dalle tensioni presenti negli involucri metallici dei cavi messi a terra da un lato o in croce.\n4 Le terre delle linee a corrente debole in cavo devono rispondere alle disposizioni dell’ordinanza del 30 marzo 1994 sulla corrente debole.\n5 Le terre delle linee a corrente forte in cavo devono rispondere alle disposizioni dell’ordinanza del 30 marzo 1994 sulla corrente forte."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-73.de.json","api_md":"/api/v1/ch/lev/art-73.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_73","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-73","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_73","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_2","num":"2. Abschnitt:","titel":"Besondere Bestimmungen für Starkstromkabelleitungen"}],"id":"ch/lev/art-73","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-73/de/","kennung":"ch/lev/art-73","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 73","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"202f0148c909352403380e4a972448a86a21a9cd2688229b9003214c130eda1e","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-73","titel":"Kabelart","typ":"stelle","url":"/ch/lev/art-73/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Für die Übertragung elektrischer Energie sind Netzkabel zu verwenden. Ausnahmen sind zulässig, wenn die Leitung ausschliesslich über Grundstücke führt, über die der Leitungsinhaber das alleinige Verfügungsrecht hat.\n2 Oberirdische Niederspannungskabel in Starkstromanlagen müssen keine leitenden Umhüllungen haben.\n3 Der Einbau von Niederspannungs‑, Signal‑, Mess- und Steuerleitern in Hochspannungskabel ist zulässig, wenn sie eine ausreichende Isolation aufweisen und keine wichtigen Schutz- oder Sicherheitsfunktionen ausüben."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-73.fr.json","api_md":"/api/v1/ch/lev/art-73.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_73","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-73","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_73","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_2","num":"2. Abschnitt:","titel":"Besondere Bestimmungen für Starkstromkabelleitungen"}],"id":"ch/lev/art-73","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-73/fr/","kennung":"ch/lev/art-73","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 73","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"b8354d50ff5e06183b8415f9a6605d970498062c6fb5f1ef294594e75036299d","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-73","titel":"Types de câbles","typ":"stelle","url":"/ch/lev/art-73/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 On utilisera des câbles de réseau pour le transport de l’énergie électrique. Des exceptions seront admises si la ligne traverse uniquement la propriété de l’exploitant.\n2 Les câbles à basse tension à ciel ouvert situés dans les installations à courant fort sont admis sans gaine conductrice.\n3 L’incorporation de conducteurs à basse tension ou de conducteurs de signalisation, de mesure et de commande dans un câble à haute tension est admise lorsqu’ils disposent d’une isolation suffisante et qu’ils n’assurent aucune fonction importante de protection ou de sécurité."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-73.it.json","api_md":"/api/v1/ch/lev/art-73.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_73","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-73","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_73","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_2","num":"2. Abschnitt:","titel":"Besondere Bestimmungen für Starkstromkabelleitungen"}],"id":"ch/lev/art-73","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-73/it/","kennung":"ch/lev/art-73","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 73","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"78cbe32125374ba429a7227f84ba7e8f19937803aa4b71de622294bde0fd66e8","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-73","titel":"Tipi di cavi","typ":"stelle","url":"/ch/lev/art-73/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Per la trasmissione dell’energia elettrica si devono impiegare cavi di rete. Sono ammesse eccezioni solamente nei casi in cui la linea attraversa terreni sui quali l’esercente della linea stessa gode del diritto esclusivo di disporre.\n2 I cavi a bassa tensione posati in superficie negli impianti a corrente forte non devono avere involucri conduttori.\n3 L’inserimento di conduttori a bassa tensione, di segnalazione, di misurazione e di comando all’interno dei cavi ad alta tensione è ammesso a condizione che essi presentino una isolazione sufficiente e non esercitino nessuna importante funzione di protezione o di sicurezza."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-74.de.json","api_md":"/api/v1/ch/lev/art-74.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_74","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-74","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_74","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_2","num":"2. Abschnitt:","titel":"Besondere Bestimmungen für Starkstromkabelleitungen"}],"id":"ch/lev/art-74","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-74/de/","kennung":"ch/lev/art-74","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 74","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"25c251260e6281f04d92f155aea5595f381da29a91277ef53b76d955be776bcb","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-74","titel":"Netzkabel","typ":"stelle","url":"/ch/lev/art-74/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Die Abstände zwischen Netzkabelleitungen und anderen – elektrischen oder nichtelektrischen – Leitungen sind so zu bemessen, dass keine unzulässigen gegenseitigen Beeinflussungen möglich sind und dass Arbeiten an der einen Leitung ohne grosse Beeinträchtigung der anderen ausgeführt werden können.\n2 Hochspannungskabel ohne geerdete leitende Umhüllung sind als unter Spannung stehend zu behandeln und so zu verlegen, dass sie auch bei Unachtsamkeit nicht berührt werden können."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-74.fr.json","api_md":"/api/v1/ch/lev/art-74.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_74","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-74","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_74","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_2","num":"2. Abschnitt:","titel":"Besondere Bestimmungen für Starkstromkabelleitungen"}],"id":"ch/lev/art-74","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-74/fr/","kennung":"ch/lev/art-74","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 74","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"f9f24df622efc903457f8f4dc5c20fec26193cc47b942f53ac2dff3838042e3e","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-74","titel":"Câbles de réseau","typ":"stelle","url":"/ch/lev/art-74/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les distances entre les lignes en câbles de réseau et d’autres lignes électriques ou encore d’autres conduites non électriques doivent être suffisantes pour exclure toute influence réciproque inadmissible et pour permettre les travaux sur une des lignes ou une des conduites sans nuire exagérément aux autres.\n2 Les lignes en câbles à haute tension sans gaine conductrice mise à la terre doivent être considérées comme étant sous tension, et posées de sorte qu’il soit impossible d’entrer en contact avec elles, même par inadvertance."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-74.it.json","api_md":"/api/v1/ch/lev/art-74.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_74","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-74","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_74","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_2","num":"2. Abschnitt:","titel":"Besondere Bestimmungen für Starkstromkabelleitungen"}],"id":"ch/lev/art-74","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-74/it/","kennung":"ch/lev/art-74","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 74","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"4c81c49db4f0ecd1a33c328d630f0adfbf5824a89a87c06a1429e969c95528a8","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-74","titel":"Cavi di rete","typ":"stelle","url":"/ch/lev/art-74/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le distanze tra i cavi di rete e le altre linee –elettriche e non elettriche –devono essere dimensionate in modo da escludere qualsiasi interferenza reciproca e da poter eseguire i lavori su una linea senza perturbazione grave delle altre.\n2 I cavi ad alta tensione senza involucro conduttore messo a terra devono essere trattati come cavi sotto tensione e posati in modo da non poter essere toccati nemmeno per inavvertenza."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-75.de.json","api_md":"/api/v1/ch/lev/art-75.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_75","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-75","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_75","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_2","num":"2. Abschnitt:","titel":"Besondere Bestimmungen für Starkstromkabelleitungen"}],"id":"ch/lev/art-75","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-75/de/","kennung":"ch/lev/art-75","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 75","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"862f60f39aaf88bb09faec68bcfdb4707e5f40fbd39f28199c8f6efcd0fbf91f","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-75","titel":"Niederspannungsnetzkabel","typ":"stelle","url":"/ch/lev/art-75/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Als leitende Umhüllung von Niederspannungsnetzkabeln ist auch ein konzentrisch angeordneter äusserer Leiter zulässig. Bei der Nullung darf nur der PEN-Leiter und bei der Schutzerdung nur der Schutzleiter PE als äusserer Leiter verwendet werden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-75.fr.json","api_md":"/api/v1/ch/lev/art-75.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_75","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-75","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_75","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_2","num":"2. Abschnitt:","titel":"Besondere Bestimmungen für Starkstromkabelleitungen"}],"id":"ch/lev/art-75","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-75/fr/","kennung":"ch/lev/art-75","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 75","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"e1b7439a227024b17aba445af20cb5ed64f5df81eaab88e4bf630a2df830ab86","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-75","titel":"Lignes en câbles de réseau à basse tension","typ":"stelle","url":"/ch/lev/art-75/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Le conducteur concentrique extérieur des lignes en câbles de réseau à basse tension peut faire office de gaine conductrice. Il peut être utilisé seulement comme conducteur PEN pour la mise au neutre et comme conducteur de protection PE pour la mise à la terre directe."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-75.it.json","api_md":"/api/v1/ch/lev/art-75.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_75","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-75","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_75","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_2","num":"2. Abschnitt:","titel":"Besondere Bestimmungen für Starkstromkabelleitungen"}],"id":"ch/lev/art-75","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-75/it/","kennung":"ch/lev/art-75","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 75","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"a55a83db48702067cd4446f30484f16441337d634aee1574c9bed7d08727b47f","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-75","titel":"Cavi di rete a bassa tensione","typ":"stelle","url":"/ch/lev/art-75/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Quale involucro di materiale conduttore dei cavi di rete a bassa tensione è ammesso anche un conduttore periferico disposto concentricamente. Nel caso di messa a terra col neutro, è ammesso, quale conduttore periferico, solo il conduttore PEN e, in presenza di una terra di protezione, solo il conduttore di protezione PE."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-76.de.json","api_md":"/api/v1/ch/lev/art-76.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_76","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-76","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_76","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_2","num":"2. Abschnitt:","titel":"Besondere Bestimmungen für Starkstromkabelleitungen"}],"id":"ch/lev/art-76","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-76/de/","kennung":"ch/lev/art-76","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 76","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"a19b0feaf9686a0ae6b971ce8557fb7fede739679a9b1b72684bbc827371877e","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-76","titel":"Gewässerschutz","typ":"stelle","url":"/ch/lev/art-76/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Enthalten Netzkabel wassergefährdende Flüssigkeiten, so ist dem Gewässerschutz besondere Beachtung zu schenken."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-76.fr.json","api_md":"/api/v1/ch/lev/art-76.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_76","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-76","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_76","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_2","num":"2. Abschnitt:","titel":"Besondere Bestimmungen für Starkstromkabelleitungen"}],"id":"ch/lev/art-76","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-76/fr/","kennung":"ch/lev/art-76","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 76","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"00e7354b9627966b7c03a756ffed97603264ca766bca725cde15cb3eeb66c922","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-76","titel":"Protection des eaux","typ":"stelle","url":"/ch/lev/art-76/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Si des câbles de réseau contiennent des liquides polluant l’eau, on accordera une attention particulière à la protection des eaux."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-76.it.json","api_md":"/api/v1/ch/lev/art-76.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_76","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-76","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_76","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_2","num":"2. Abschnitt:","titel":"Besondere Bestimmungen für Starkstromkabelleitungen"}],"id":"ch/lev/art-76","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-76/it/","kennung":"ch/lev/art-76","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 76","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"48a6af7267e28eb73417559f6ae0d0ac79dbf73ef45a848143cf771ace5f4aac","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-76","titel":"Protezione delle acque","typ":"stelle","url":"/ch/lev/art-76/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Se i cavi di rete contengono liquidi inquinanti, occorre prestare particolare attenzione alla protezione delle acque."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-77.de.json","api_md":"/api/v1/ch/lev/art-77.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_77","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-77","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_77","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_2","num":"2. Abschnitt:","titel":"Besondere Bestimmungen für Starkstromkabelleitungen"}],"id":"ch/lev/art-77","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-77/de/","kennung":"ch/lev/art-77","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 77","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"69e6623522bd51296feacfb8c4bd7246d786919609fe39d1c0aae0e6c3edeef0","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-77","titel":"Markierung","typ":"stelle","url":"/ch/lev/art-77/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Die Trassees der Hochspannungskabelleitungen müssen markiert werden (z. B. durch Warnbänder). In dicht besiedelten Gebieten kann darauf verzichtet werden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-77.fr.json","api_md":"/api/v1/ch/lev/art-77.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_77","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-77","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_77","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_2","num":"2. Abschnitt:","titel":"Besondere Bestimmungen für Starkstromkabelleitungen"}],"id":"ch/lev/art-77","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-77/fr/","kennung":"ch/lev/art-77","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 77","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"94050876c9eb7763bdf3b3d18efdac2f0e53754bd61e45f7425046b4cbb26433","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-77","titel":"Repérage","typ":"stelle","url":"/ch/lev/art-77/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les tracés des lignes en câbles à haute tension doivent être repérés (par exemple au moyen de bandes d’avertissement). Des exceptions sont admises dans les régions à forte densité de population."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-77.it.json","api_md":"/api/v1/ch/lev/art-77.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_77","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-77","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_77","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_2","num":"2. Kapitel:","titel":"Kabelleitungen"},{"ebene":"section","eid":"tit_2/chap_2/sec_2","num":"2. Abschnitt:","titel":"Besondere Bestimmungen für Starkstromkabelleitungen"}],"id":"ch/lev/art-77","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-77/it/","kennung":"ch/lev/art-77","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 77","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"aa82731567a8c090bfd34647216356a3eb6e41f86059c94b6a18248ce4dabc9e","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-77","titel":"Marcatura","typ":"stelle","url":"/ch/lev/art-77/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Il tracciato delle linee ad alta tensione in cavo deve essere contrassegnato (ad es. per mezzo di nastri monitori). Vi si può rinunciare nelle aree densamente popolate."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-78.de.json","api_md":"/api/v1/ch/lev/art-78.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_78","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-78","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_78","fussnoten":[{"marker":"32","nummer":32,"text":"Fassung gemäss Anhang Ziff. 5 der V vom 8. Dez. 1997, in Kraft seit 1. Jan. 1998 (AS 1998 54)."},{"marker":"33","nummer":33,"text":"Aufgehoben durch Anhang Ziff. 5 der V vom 8. Dez. 1997, mit Wirkung seit 1. Jan. 1998 (AS 1998 54)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-78","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-78/de/","kennung":"ch/lev/art-78","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 78","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"1811bdfb1c14fa4059133e77af34f5428ca667c36d32a6e553a60e17b1a9cc6b","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-78","titel":"Zulässigkeit und Leitungsführung","typ":"stelle","url":"/ch/lev/art-78/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Annäherungen, Parallelführungen und Kreuzungen von Freileitungen unter sich auf gemeinsamen Tragwerken sind nur zulässig, wenn:\na. alle Leitungen dem gleichen Betriebsinhaber unterstellt sind;\nb. die beteiligten Betriebsinhaber Erstellung, Betrieb und Instandhaltung schriftlich vereinbart haben.\n2 …\n3 Freileitungen sind so zu planen und zu erstellen, dass wenig Kreuzungen mit anderen Freileitungen entstehen.\n4 Lassen sich Kreuzungen nicht vermeiden, so sind sie möglichst nahe bei den Überführungstragwerken anzulegen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-78.fr.json","api_md":"/api/v1/ch/lev/art-78.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_78","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-78","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_78","fussnoten":[{"marker":"31","nummer":31,"text":"Nouvelle teneur selon l’annexe ch. 5 de l’O du 8 déc. 1997, en vigueur depuis le 1er janv. 1998 (RO 1998 54)."},{"marker":"32","nummer":32,"text":"Abrogé par l’annexe ch. 5 de l’O du 8 déc. 1997, avec effet au 1er janv. 1998 (RO 1998 54)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-78","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-78/fr/","kennung":"ch/lev/art-78","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 78","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"19ddef388b7f1ee3b2696fe0da71755dc502e14d7f7f18b9eb06ae24b8dd2068","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-78","titel":"Tracé des lignes aériennes","typ":"stelle","url":"/ch/lev/art-78/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les rapprochements, les parallélismes et les croisements de lignes aériennes entre elles sur des supports communs ne sont admis que:\na. si toutes les lignes appartiennent au même exploitant;\nb. si l’établissement, l’exploitation et l’entretien sont réglés par des conventions écrites entre les exploitants concernés.\n2 …\n3 Les lignes aériennes doivent être planifiées et disposées de manière qu’elles se croisent le moins possible.\n4 Si les croisements ne peuvent être évités, ils doivent, dans la mesure du possible, avoir lieu à proximité des supports de la ligne supérieure."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-78.it.json","api_md":"/api/v1/ch/lev/art-78.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_78","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-78","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_78","fussnoten":[{"marker":"33","nummer":33,"text":"Nuovo testo giusta l’all. n. 5 dell’O dell’8 dic. 1997, in vigore dal 1° gen. 1998 (RU 1998 54)."},{"marker":"34","nummer":34,"text":"Abrogato dall’all. n. 5 dell’O dell’8 dic. 1997, con effetto dal 1° gen. 1998 (RU 1998 54)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-78","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-78/it/","kennung":"ch/lev/art-78","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 78","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"28dcb92dc4b14d4c675ae43baabba3e09bcf83cbfb03d9c4c722895f58cbe99c","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-78","titel":"Ammissibilità e tracciato","typ":"stelle","url":"/ch/lev/art-78/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Vicinanze, parallelismi e incroci delle linee aeree tra loro su sostegni in comune sono ammessi solo se:\na. tutte le linee sono sottoposte allo stesso esercente;\nb. gli esercenti interessati hanno concordato per iscritto le modalità concernenti la costruzione, l’esercizio e la manutenzione.\n2 …\n3 Le linee aeree devono essere progettate e costruite in modo da ridurre al minimo il numero degli incroci con altre linee aeree.\n4 Se gli incroci sono inevitabili, essi vanno disposti, per quanto possibile, in prossimità del sostegno della linea sovrapassante."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-79.de.json","api_md":"/api/v1/ch/lev/art-79.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_79","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-79","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_79","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-79","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-79/de/","kennung":"ch/lev/art-79","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 79","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"d2fd9e43de60108032eb7085f75e3ba44d5919bca2eaa9fef27cb34782628039","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-79","titel":"Anordnung von Freileitungen","typ":"stelle","url":"/ch/lev/art-79/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Bei Annäherungen, Parallelführungen und Kreuzungen von Freileitungen unter sich sind die Leiter mit höherer Spannung über den Leitern mit tieferer Spannung anzuordnen.\n2 Werden bei Parallelführungen oder Kreuzungen ausnahmsweise Leiter mit tieferer Spannung über Leiter mit höherer Spannung geführt, so müssen die Leiter mit tieferer Spannung den Bestimmungen über die mechanische Sicherheit der Leiter mit höherer Spannung entsprechen. Bei solchen Kreuzungen müssen die übergeführten Leiter durch starre Befestigungen gehalten werden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-79.fr.json","api_md":"/api/v1/ch/lev/art-79.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_79","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-79","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_79","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-79","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-79/fr/","kennung":"ch/lev/art-79","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 79","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"77f564567901feb2ddea478aeaa846c5389b2ff3715c455736bf1b391339edcd","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-79","titel":"Disposition des lignes aériennes","typ":"stelle","url":"/ch/lev/art-79/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 En cas de rapprochements, de parallélismes et de croisements de lignes aériennes entre elles, les conducteurs du niveau de tension le plus élevé doivent être placés au-dessus de ceux qui ont un niveau de tension plus faible.\n2 Lorsque, en cas de parallélismes et de croisements, les conducteurs du niveau de tension le plus élevé sont exceptionnellement survolés par les conducteurs d’un niveau de tension plus faible, les dispositions sur la sécurité mécanique de ces derniers doivent correspondre à celles des conducteurs du niveau de tension le plus élevé. Lors de tels croisements, les conducteurs de la ligne supérieure doivent être équipés de fixations rigides."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-79.it.json","api_md":"/api/v1/ch/lev/art-79.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_79","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-79","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_79","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-79","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-79/it/","kennung":"ch/lev/art-79","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 79","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"3821add0b6bfbe633e560983532d6b60e49c6e90a97d33d90bc304d4cb637bab","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-79","titel":"Disposizione delle linee aeree","typ":"stelle","url":"/ch/lev/art-79/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Nei casi di vicinanze, parallelismi ed incroci di linee aeree tra loro, i conduttori a tensione più elevata devono essere disposti al disopra dei conduttori a tensione più bassa.\n2 Se, eccezionalmente, i conduttori a tensione più alta sono tesati, ad un parallelismo od incrocio, sopra ai conduttori a tensione più alta, i primi devono soddisfare le disposizioni in materia di sicurezza meccanica vigenti per i conduttori di tensione più elevata. I conduttori superiori devono essere tenuti da fissaggi rigidi."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-80.de.json","api_md":"/api/v1/ch/lev/art-80.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_80","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-80","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_80","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-80","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-80/de/","kennung":"ch/lev/art-80","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 80","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"38b24f32f7d2cada706bd2bab3be1734bf091ef4c669e8bc50a7c98ae56e6a85","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-80","titel":"Mechanischer Schutz für herabführende Leiter","typ":"stelle","url":"/ch/lev/art-80/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Erdleiter oder Kabel, die an Tragwerken herabgeführt werden, sind ab Erdboden bis in eine genügende Höhe gegen mechanische Beschädigung zu schützen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-80.fr.json","api_md":"/api/v1/ch/lev/art-80.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_80","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-80","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_80","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-80","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-80/fr/","kennung":"ch/lev/art-80","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 80","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"e4e87dea4d88def4cad703012897a85aa7333f79571e34a3cb7d53f5714f05b6","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-80","titel":"Protection mécanique des descentes de conducteurs","typ":"stelle","url":"/ch/lev/art-80/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Sur les supports, les descentes de conducteurs de terre ou de câbles doivent être protégées des détériorations mécaniques jusqu’à une hauteur suffisante au-dessus du sol."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-80.it.json","api_md":"/api/v1/ch/lev/art-80.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_80","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-80","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_80","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-80","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-80/it/","kennung":"ch/lev/art-80","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 80","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"4f8cbfc07fba0891128a6c87ccd8a73dd38563eaf677043d9cd2b83cbe4fbf20","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-80","titel":"Protezione meccanica dei conduttori portati verso il basso","typ":"stelle","url":"/ch/lev/art-80/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"I conduttori di terra o i cavi che vengono fatti discendere lungo i sostegni devono essere protetti, a partire dal suolo e fino ad una altezza sufficiente, contro i danni di origine meccanica."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-81.de.json","api_md":"/api/v1/ch/lev/art-81.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_81","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-81","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_81","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-81","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-81/de/","kennung":"ch/lev/art-81","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 81","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"4206eaa0e3608537fdcfba0ddcbd12085e70840b0f3d85248aee18c38af5fe44","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-81","titel":"Abstände","typ":"stelle","url":"/ch/lev/art-81/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich sind so anzulegen, dass zwischen Leitern verschiedener Leitungen keine Spannungsübertritte auftreten können.\n2 Die Abstände, die bei Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich eingehalten werden müssen, bestimmen sich nach Anhang 17. Annäherungen, Parallelführungen und Kreuzungen von isolierten Schwachstromleitungen unter sich sind ohne Einhaltung von Sicherheitsabständen zulässig.\n3 Der Sicherheitsabstand bei Kreuzungen ist aufgrund folgender Annahmen zu berechnen:\na. oberer Leiter: 0 °C Leitertemperatur und Zusatzlast, unter Berücksichtigung einer möglichen Durchhangsvergrösserung bei bedingt gleitender Leiterbefestigung oder beweglicher Leiteraufhängung;\nb. unterer Leiter: 0 °C Leitertemperatur ohne Zusatzlast.\n4 Die Betriebsinhaber sind verpflichtet, sich gegenseitig die für die Berechnung der Abstände erforderlichen Angaben zu liefern."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-81.fr.json","api_md":"/api/v1/ch/lev/art-81.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_81","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-81","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_81","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-81","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-81/fr/","kennung":"ch/lev/art-81","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 81","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"05f74923b8784f06044496d2bd17459bc90f5c63a4a8ac8fd25fb9f927ec18c3","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-81","titel":"Distances","typ":"stelle","url":"/ch/lev/art-81/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les rapprochements, les parallélismes et les croisements de lignes électriques entre elles doivent être conçus pour éviter les transferts de potentiels entre les conducteurs des différentes lignes.\n2 Les distances à respecter en cas de rapprochements, de parallélismes et de croisements de lignes électriques entre elles sont données à l’annexe 17. Aucune distance de sécurité n’est prescrite pour les rapprochements, les parallélismes et les croisements de lignes isolées à courant faible entre elles.\n3 La distance de sécurité en cas de croisements se calcule à partir des hypothèses suivantes:\na. pour le conducteur supérieur: une température du conducteur de 0° C avec surcharge en tenant compte d’une augmentation possible de la flèche en présence de fixations à glissement limité ou de suspensions mobiles;\nb. pour le conducteur inférieur: une température du conducteur de 0° C sans surcharge.\n4 Les exploitants sont tenus de se fournir mutuellement les données nécessaires au calcul des distances."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-81.it.json","api_md":"/api/v1/ch/lev/art-81.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_81","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-81","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_81","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-81","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-81/it/","kennung":"ch/lev/art-81","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 81","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"4e53ab01f1b8e18c6d1aef4c715478d7dd329bedd0104ffe0ba6f89b432f6c21","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-81","titel":"Distanze","typ":"stelle","url":"/ch/lev/art-81/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le vicinanze, i parallelismi e gli incroci tra linee elettriche devono essere eseguiti in modo che tra i conduttori di linee diverse non si verifichino trasferimenti di tensione.\n2 Le distanze da rispettare nei casi di vicinanze, parallelismi ed incroci delle linee elettriche tra loro sono fissate nell’appendice 17. Le vicinanze, i parallelismi e gli incroci delle linee isolate a corrente debole tra loro sono ammessi senza dover rispettare nessuna distanza di sicurezza.\n3 Agli incroci, la distanza di sicurezza deve essere dimensionata sulla base delle ipotesi seguenti:\na. conduttore superiore: temperatura di 0° C e sovraccarico, tenendo conto di un possibile aumento della freccia in seguito a scorrimento vincolato dei conduttori o allo spostamento delle sospensioni mobili;\nb. conduttore inferiore: temperatura di 0° C, senza sovraccarico.\n4 Gli esercenti sono tenuti a scambiarsi vicendevolmente i dati necessari ai calcoli delle distanze."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-82.de.json","api_md":"/api/v1/ch/lev/art-82.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_82","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-82","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_82","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-82","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-82/de/","kennung":"ch/lev/art-82","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 82","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"96e9f3b37d52718fdd4d3f9a8bb3f4eced36cfd97c8f26785e817ef778304360","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-82","titel":"Besteigen der Tragwerke","typ":"stelle","url":"/ch/lev/art-82/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Unterkreuzende Leitungen dürfen das Besteigen der Tragwerke nicht behindern oder gefährden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-82.fr.json","api_md":"/api/v1/ch/lev/art-82.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_82","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-82","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_82","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-82","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-82/fr/","kennung":"ch/lev/art-82","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 82","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"7f4a9f66c0002b1193e3f6b6c5c7685b80a22328a9f6f3c3e530e81e4a8aa00d","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-82","titel":"Escalade des supports","typ":"stelle","url":"/ch/lev/art-82/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"À l’endroit des croisements, les lignes inférieures ne doivent pas gêner ni rendre dangereuse l’escalade des supports des lignes supérieures."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-82.it.json","api_md":"/api/v1/ch/lev/art-82.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_82","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-82","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_82","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmungen"}],"id":"ch/lev/art-82","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-82/it/","kennung":"ch/lev/art-82","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 82","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"62a30c7062979e39defdb0fb487b6c1f0d17908ff7c74fa3255d564767220dbb","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-82","titel":"Scalata dei sostegni","typ":"stelle","url":"/ch/lev/art-82/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Agli incroci, i conduttori sottopassanti non devono ostacolare o rendere pericolosa la scalata dei sostegni."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-83.de.json","api_md":"/api/v1/ch/lev/art-83.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_83","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-83","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_83","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Schwachstrom- und Starkstromfreileitungen"}],"id":"ch/lev/art-83","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-83/de/","kennung":"ch/lev/art-83","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 83","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"378ef0e16dc9b9d8d3a324b03db0fbe8227e98326ea829f39a37cc1b96ab2e2c","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-83","titel":"Schwachstrom- und Niederspannungsleitungen auf gemeinsamen Tragwerken","typ":"stelle","url":"/ch/lev/art-83/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Ankerseile von gemeinsamen Tragwerken müssen mit Isolierkörpern so unterteilt werden, dass durch lose oder defekte Ankerseile keine leitenden Verbindungen zwischen Schwachstrom- und Niederspannungsleitern entstehen.\n2 Erdleiter oder Niederspannungskabel, die an Tragwerken herabgeführt werden, sind ab Erdboden bis 0,50 m über die Schwachstromleitung hinaus gegen mechanische Beschädigung zu schützen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-83.fr.json","api_md":"/api/v1/ch/lev/art-83.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_83","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-83","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_83","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Schwachstrom- und Starkstromfreileitungen"}],"id":"ch/lev/art-83","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-83/fr/","kennung":"ch/lev/art-83","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 83","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"82d7a7a8acacb1b60827c5fa9ac18a226d64b4050181d38f1cb6b5bebc03b1b5","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-83","titel":"Lignes à courant faible et lignes à basse tension sur supports communs","typ":"stelle","url":"/ch/lev/art-83/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les haubans de supports communs doivent être subdivisés au moyen de pièces isolantes afin qu’ils ne puissent provoquer de liaison conductrice entre des conducteurs à courant faible et des conducteurs à basse tension s’ils venaient à se détacher ou à se détériorer.\n2 Sur les supports, les descentes de conducteurs de terre ou de câbles à basse tension doivent être protégées des détériorations mécaniques depuis le sol et jusqu’à 0,5 m au-dessus de la ligne à courant faible."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-83.it.json","api_md":"/api/v1/ch/lev/art-83.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_83","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-83","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_83","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Schwachstrom- und Starkstromfreileitungen"}],"id":"ch/lev/art-83","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-83/it/","kennung":"ch/lev/art-83","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 83","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"64fdc22a25c47a6a08bca06f61967a0f9a063ae3d9fa0c6e290bee8b4cb0c109","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-83","titel":"Linee a corrente debole e linee a bassa tensione su sostegni in comune","typ":"stelle","url":"/ch/lev/art-83/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le funi di ancoraggio dei sostegni in comune devono essere suddivise mediante corpi isolanti in modo che una fune sciolta o difettosa non possa stabilire nessun collegamento elettrico tra i conduttori a corrente debole e quelli a bassa tensione.\n2 I conduttori di terra o i cavi a bassa tensione che vengono fatti scendere lungo i sostegni devono essere protetti, a partire dal suolo e fino ad una altezza di 0,50 m al disopra del conduttore a corrente debole, contro i danni di origine meccanica."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-84.de.json","api_md":"/api/v1/ch/lev/art-84.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_84","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-84","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_84","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Schwachstrom- und Starkstromfreileitungen"}],"id":"ch/lev/art-84","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-84/de/","kennung":"ch/lev/art-84","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 84","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"3bfcb450c4ede248d6d5e4f1fdaac35e302ba011e02743f3f316e636cd8b74ee","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-84","titel":"Schwachstrom- und Niederspannungsleitungen an Gebäuden","typ":"stelle","url":"/ch/lev/art-84/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Abspannstellen von Niederspannungsleitungen an Mauerwerken oder Gebäuden müssen oberhalb derjenigen von Schwachstromleitungen angebracht werden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-84.fr.json","api_md":"/api/v1/ch/lev/art-84.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_84","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-84","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_84","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Schwachstrom- und Starkstromfreileitungen"}],"id":"ch/lev/art-84","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-84/fr/","kennung":"ch/lev/art-84","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 84","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"0f14bf806386da8420aa0fec763d42f349bb4e09eac312f397b1608a5eec2adc","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-84","titel":"Lignes à courant faible et lignes à basse tension fixées aux bâtiments","typ":"stelle","url":"/ch/lev/art-84/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les points de fixation des lignes à basse tension aux ouvrages de maçonnerie ou aux bâtiments doivent être disposés au-dessus de ceux des lignes à courant faible."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-84.it.json","api_md":"/api/v1/ch/lev/art-84.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_84","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-84","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_84","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Schwachstrom- und Starkstromfreileitungen"}],"id":"ch/lev/art-84","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-84/it/","kennung":"ch/lev/art-84","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 84","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"e2b95993aa45242880c11ff3423fdc39626cc1454f9daac8126ccc7908271953","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-84","titel":"Linee a corrente debole e linee a bassa tensione in prossimità dei fabbricati","typ":"stelle","url":"/ch/lev/art-84/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"I punti di ancoraggio delle linee a bassa tensione a opere murarie o a fabbricati devono essere disposti al disopra dei punti di ancoraggio delle linee a corrente debole."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-85.de.json","api_md":"/api/v1/ch/lev/art-85.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_85","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-85","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_85","fussnoten":[{"marker":"34","nummer":34,"text":"Aufgehoben durch Anhang Ziff. 5 der V vom 8. Dez. 1997, mit Wirkung seit 1. Jan. 1998 (AS 1998 54)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Schwachstrom- und Starkstromfreileitungen"}],"id":"ch/lev/art-85","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-85/de/","kennung":"ch/lev/art-85","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 85","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"e80d0c224cd36d0ac8b453cb59c1c9aff51228cd926837d46b1a027f76695ccc","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-85","titel":"Parallelführungen von Schwachstrom- und Hochspannungsleitungen auf gemeinsamen Tragwerken","typ":"stelle","url":"/ch/lev/art-85/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 …\n2 Auf der ganzen Länge der Parallelführung müssen die blanken Hochspannungsleiter durch starre Befestigungen gehalten werden. Die Schwachstromleiter müssen den Bestimmungen über die mechanische Sicherheit der Hochspannungsleiter entsprechen.\n3 Parallelführungen von Schwachstromleitungen und Hochspannungs-Luftkabeln sind auf gemeinsamen Tragwerken zulässig.\n4 Die Schwachstromleitungen müssen für den 1,3 fachen Wert der höchstmöglichen Erdungsspannung isoliert werden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-85.fr.json","api_md":"/api/v1/ch/lev/art-85.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_85","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-85","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_85","fussnoten":[{"marker":"33","nummer":33,"text":"Abrogé par l’annexe ch. 5 de l’O du 8 déc. 1997, avec effet au 1er janv. 1998 (RO 1998 54)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Schwachstrom- und Starkstromfreileitungen"}],"id":"ch/lev/art-85","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-85/fr/","kennung":"ch/lev/art-85","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 85","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"ba191c009e6c5101fe469a3fc0194ea337bad1a145c030d5879b70d747254534","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-85","titel":"Parallélismes de lignes à courant faible et de lignes à haute tension sur des supports communs","typ":"stelle","url":"/ch/lev/art-85/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 …\n2 Les conducteurs nus à haute tension doivent être équipés de fixations rigides sur toute la longueur du parallélisme. Les conducteurs à courant faible doivent satisfaire aux dispositions sur la sécurité mécanique valables pour les conducteurs à haute tension.\n3 Les parallélismes de lignes à courant faible et de câbles aériens à haute tension sur des supports communs sont admis.\n4 Les lignes à courant faible doivent être isolées pour une tension correspondant à 1,3 fois la valeur de la tension de terre maximale susceptible d’apparaître."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-85.it.json","api_md":"/api/v1/ch/lev/art-85.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_85","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-85","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_85","fussnoten":[{"marker":"35","nummer":35,"text":"Abrogato dall’all. n. 5 dell’O dell’8 dic. 1997, con effetto dal 1° gen. 1998 (RU 1998 54)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Schwachstrom- und Starkstromfreileitungen"}],"id":"ch/lev/art-85","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-85/it/","kennung":"ch/lev/art-85","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 85","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"01cd5385156e7f57e0ed6a5dd7706808ef9fd8d8ae27910aa5dc6a6d87d7fedc","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-85","titel":"Parallelismi di linee a corrente debole e linee ad alta tensione su sostegni in comune","typ":"stelle","url":"/ch/lev/art-85/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 …\n2 Lungo tutto il percorso del parallelismo, i conduttori nudi ad alta tensione devono essere dotati di fissaggi rigidi. I conduttori a corrente debole devono rispondere alle esigenze di sicurezza meccanica imposte ai conduttori ad alta tensione.\n3 I parallelismi di linee a corrente debole con cavi aerei ad alta tensione su sostegni in comune sono ammessi.\n4 Le linee a corrente debole devono essere isolate per una tensione pari a 1,3 volte il valore più alto possibile del potenziale contro terra."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-86.de.json","api_md":"/api/v1/ch/lev/art-86.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_86","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-86","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_86","fussnoten":[{"marker":"35","nummer":35,"text":"Aufgehoben durch Anhang Ziff. 5 der V vom 8. Dez. 1997, mit Wirkung seit 1. Jan. 1998 (AS 1998 54)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Schwachstrom- und Starkstromfreileitungen"}],"id":"ch/lev/art-86","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-86/de/","kennung":"ch/lev/art-86","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 86","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"313eefda894db8bbebdd1f7f5d0947cb677dbc3c9e9f65631f8fa146e255e828","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-86","titel":"Kreuzungen von Schwachstrom- und Hochspannungsleitungen auf gemeinsamen Tragwerken","typ":"stelle","url":"/ch/lev/art-86/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 …\n2 Kreuzungen von Schwachstromleitungen mit Hochspannungs-Luftkabeln sind auf gemeinsamen Tragwerken zulässig.\n3 Die Schwachstromleitungen müssen für den 1,3 fachen Wert der höchstmöglichen Erdungsspannung isoliert werden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-86.fr.json","api_md":"/api/v1/ch/lev/art-86.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_86","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-86","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_86","fussnoten":[{"marker":"34","nummer":34,"text":"Abrogé par l’annexe ch. 5 de l’O du 8 déc. 1997, avec effet au 1er janv. 1998 (RO 1998 54)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Schwachstrom- und Starkstromfreileitungen"}],"id":"ch/lev/art-86","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-86/fr/","kennung":"ch/lev/art-86","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 86","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"55088f89f8ce4eb5ba1e44d4f3435465abe426d39bea063dff65a41cd2648076","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-86","titel":"Croisements de lignes à courant faible et de lignes à haute tension sur des supports communs","typ":"stelle","url":"/ch/lev/art-86/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 …\n2 Les croisements de lignes à courant faible avec des câbles aériens à haute tension sur des supports communs sont admis.\n3 Les lignes à courant faible doivent être isolées pour une tension correspondant à 1,3 fois la valeur de la tension de terre maximale susceptible d’apparaître."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-86.it.json","api_md":"/api/v1/ch/lev/art-86.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_86","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-86","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_86","fussnoten":[{"marker":"36","nummer":36,"text":"Abrogato dall’all. n. 5 dell’O dell’8 dic. 1997, con effetto dal 1° gen. 1998 (RU 1998 54)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Schwachstrom- und Starkstromfreileitungen"}],"id":"ch/lev/art-86","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-86/it/","kennung":"ch/lev/art-86","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 86","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"1f0f93e23a8cb1a68819f5924a67becf813eabe1cfd4815de252bb9b18dd1e26","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-86","titel":"Incroci di linee a corrente debole e linee ad alta tensione su sostegni in comune","typ":"stelle","url":"/ch/lev/art-86/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 …\n2 Gli incroci delle linee a corrente debole con cavi aerei ad alta tensione su sostegni in comune sono ammessi.\n3 Le linee a corrente debole devono essere isolate per una tensione pari a 1,3 volte il valore più alto possibile del potenziale contro terra."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-87.de.json","api_md":"/api/v1/ch/lev/art-87.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_87","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-87","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_87","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Schwachstrom- und Starkstromfreileitungen"}],"id":"ch/lev/art-87","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-87/de/","kennung":"ch/lev/art-87","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 87","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"5121aa810b251b93f3f54af57401b486ba2dac5f6e0264fce526a2bf73bad1cd","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-87","titel":"Kreuzungen von Schwachstrom- und Starkstromleitungen bei getrennten Tragwerken","typ":"stelle","url":"/ch/lev/art-87/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Kreuzt sich eine Schwachstromleitung mit einer Starkstromleitung so, dass ein allfälliges Aufschnellen eines Schwachstromleiters eine gefährliche Annäherung an die Starkstromleitung verursacht, sind entsprechende Schutzmassnahmen zu treffen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-87.fr.json","api_md":"/api/v1/ch/lev/art-87.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_87","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-87","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_87","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Schwachstrom- und Starkstromfreileitungen"}],"id":"ch/lev/art-87","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-87/fr/","kennung":"ch/lev/art-87","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 87","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"2fee442b43dcb412667e63d44ff0b66b87f3a929517385da8a5d581e0d0f2fe1","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-87","titel":"Croisements de lignes à courant faible et de lignes à courant fort sur des supports distincts","typ":"stelle","url":"/ch/lev/art-87/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Lorsque le croisement d’une ligne à courant faible avec une ligne à courant fort est disposé de façon que le rebondissement d’un conducteur à courant faible puisse provoquer un rapprochement dangereux avec la ligne à courant fort, on prendra les mesures de protection adéquates."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-87.it.json","api_md":"/api/v1/ch/lev/art-87.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_87","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-87","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_87","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Schwachstrom- und Starkstromfreileitungen"}],"id":"ch/lev/art-87","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-87/it/","kennung":"ch/lev/art-87","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 87","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"cd108e9a46991ee237e579d10018db3e1a0f80e2f10385b567251d725ab14a06","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-87","titel":"Incroci di linee a corrente debole e linee a corrente forte su sostegni separati","typ":"stelle","url":"/ch/lev/art-87/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Se una linea a corrente debole incrocia una linea a corrente forte in modo che, in seguito ad un eventuale sbalzo, un conduttore della linea a corrente debole possa avvicinarsi pericolosamente alla linea a corrente forte, si devono prendere appropriate misure di protezione."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-88.de.json","api_md":"/api/v1/ch/lev/art-88.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_88","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-88","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_88","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Starkstromfreileitungen unter sich"}],"id":"ch/lev/art-88","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-88/de/","kennung":"ch/lev/art-88","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 88","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"23cf2cfc89c08ad324523a12c5a708e4e0bb9750caf785daa4c279348e63143d","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-88","titel":"Mehrere parallele Starkstromfreileitungen","typ":"stelle","url":"/ch/lev/art-88/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Werden mehr als zwei Starkstromfreileitungen auf getrennten Tragwerken parallel geführt, so müssen die Betriebsinhaber der Leitungen die besonderen Sicherheitsvorkehren bei Instandhaltungsarbeiten auf diesen Leitungsabschnitten schriftlich vereinbaren."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-88.fr.json","api_md":"/api/v1/ch/lev/art-88.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_88","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-88","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_88","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Starkstromfreileitungen unter sich"}],"id":"ch/lev/art-88","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-88/fr/","kennung":"ch/lev/art-88","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 88","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"46831bf90ff0ae48987e3749175712b6638c4b8653437bfcbe949c5a90e38332","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-88","titel":"Lignes aériennes à courant fort en parallèle","typ":"stelle","url":"/ch/lev/art-88/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Si plus de deux lignes aériennes à courant fort doivent être établies en parallèle sur des supports distincts, les exploitants des lignes déterminent par convention écrite les mesures de sécurité particulières à prendre lors des travaux d’entretien sur ces tronçons de ligne."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-88.it.json","api_md":"/api/v1/ch/lev/art-88.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_88","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-88","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_88","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Starkstromfreileitungen unter sich"}],"id":"ch/lev/art-88","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-88/it/","kennung":"ch/lev/art-88","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 88","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"4ed1be16f06f1ed7e3aed1e20761ac1b952859a0ffa2d3567c7cc695f5865a8c","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-88","titel":"Più linee aeree a corrente forte in parallelo","typ":"stelle","url":"/ch/lev/art-88/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Se più di due linee aeree a corrente forte su sostegni separati seguono un tracciato parallelo, gli esercenti delle linee devono stipulare una convenzione scritta sulle particolari misure di sicurezza da adottare per i lavori di manutenzione lungo questa tratta."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-89.de.json","api_md":"/api/v1/ch/lev/art-89.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_89","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-89","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_89","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Starkstromfreileitungen unter sich"}],"id":"ch/lev/art-89","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-89/de/","kennung":"ch/lev/art-89","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 89","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"7b2ac3c0c94a5f600d63389db466d246670b5134de5e9536d2c4438e7d0c7999","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-89","titel":"Abstände","typ":"stelle","url":"/ch/lev/art-89/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Bei Parallelführung von Starkstromfreileitungen auf getrennten Tragwerken dürfen die Direktabstände statt nach Anhang 17 nach Anhang 6 berechnet werden, wenn:\na. der unterste Leiter der einen Leitung bei 0 °C und Zusatzlast um mindestens 1 m höher ist als der oberste Leiter der anderen Leitung bei 0 °C ohne Zusatzlast; und\nb. die beteiligten Betriebsinhaber ihr Einverständnis gegeben haben."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-89.fr.json","api_md":"/api/v1/ch/lev/art-89.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_89","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-89","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_89","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Starkstromfreileitungen unter sich"}],"id":"ch/lev/art-89","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-89/fr/","kennung":"ch/lev/art-89","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 89","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"42d75c4960b88a5c369f66f77a2ec086852dba1f80a156fb89d719a8a2ce122b","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-89","titel":"Distances","typ":"stelle","url":"/ch/lev/art-89/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"En cas de parallélismes de lignes aériennes à courant fort sur des supports distincts, les distances directes peuvent se calculer selon l’annexe 6 et non plus selon l’annexe 17:\na. si le conducteur inférieur d’une ligne à 0° C avec surcharge se trouve au moins 1 m plus haut que le conducteur supérieur de l’autre ligne à 0° C sans surcharge; et\nb. si les exploitants concernés ont donné leur accord."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-89.it.json","api_md":"/api/v1/ch/lev/art-89.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_89","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-89","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_89","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Starkstromfreileitungen unter sich"}],"id":"ch/lev/art-89","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-89/it/","kennung":"ch/lev/art-89","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 89","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"7e64ff3d28a2b0ed44e55b4c8768b7331c769510e6b419dc61ef0edd9fbf2fe1","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-89","titel":"Distanze","typ":"stelle","url":"/ch/lev/art-89/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Nel caso di parallelismo di linee aeree a corrente forte su sostegni separati, le distanze dirette possono non essere calcolate secondo l’appendice 17, ma conformemente all’appendice 6 quando:\na. il conduttore più basso di una linea, alla temperatura di 0° C e con sovraccarico, si trova ad almeno 1 m al disopra del conduttore più alto dell’altra linea alla temperatura di 0° C ma senza sovraccarico; e\nb. gli esercenti interessati hanno dato il loro accordo."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-90.de.json","api_md":"/api/v1/ch/lev/art-90.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_90","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-90","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_90","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Starkstromfreileitungen unter sich"}],"id":"ch/lev/art-90","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-90/de/","kennung":"ch/lev/art-90","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 90","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"abfa00f79d565063343f48830615a5c5479ead38fd96d75e3755b3a3b96a31cf","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-90","titel":"Nachträgliche Kreuzungen","typ":"stelle","url":"/ch/lev/art-90/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Muss für die Kreuzung von Starkstromfreileitungen ausnahmsweise ein bestehendes Tragwerk benutzt werden, so hat die mechanische Festigkeit von Tragwerk und Fundament den neuen Belastungen zu entsprechen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-90.fr.json","api_md":"/api/v1/ch/lev/art-90.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_90","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-90","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_90","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Starkstromfreileitungen unter sich"}],"id":"ch/lev/art-90","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-90/fr/","kennung":"ch/lev/art-90","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 90","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"11226f628c824657259fc40923deb0d0e9b829d9a11424b2afbeb711048c2826","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-90","titel":"Croisements ultérieurs","typ":"stelle","url":"/ch/lev/art-90/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Lorsque un croisement de lignes aériennes à courant fort doit être effectué exceptionnellement après coup sur un support commun non initialement prévu à cet effet, la résistance mécanique du support et de sa fondation doit satisfaire aux nouvelles charges."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-90.it.json","api_md":"/api/v1/ch/lev/art-90.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_90","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-90","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_90","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Starkstromfreileitungen unter sich"}],"id":"ch/lev/art-90","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-90/it/","kennung":"ch/lev/art-90","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 90","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"3ac5aa664335307ed2a168ef3609464c4261684a6e5896410e2f3f3fe041573f","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-90","titel":"Incroci realizzati successivamente","typ":"stelle","url":"/ch/lev/art-90/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Qualora si debba utilizzare, in via eccezionale, un sostegno esistente per realizzare un incrocio tra linee a corrente forte, la resistenza meccanica del sostegno e della fondazione deve rispondere alle nuove sollecitazioni."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-91.de.json","api_md":"/api/v1/ch/lev/art-91.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_91","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-91","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_91","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Starkstromfreileitungen unter sich"}],"id":"ch/lev/art-91","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-91/de/","kennung":"ch/lev/art-91","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 91","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"2cd00728234b2b937b417f1ce97b1b8d500d4fee855bec8a2cbf247c6fc0d487","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-91","titel":"Leitungsanordnung","typ":"stelle","url":"/ch/lev/art-91/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Bei Kreuzungen von Starkstromfreileitungen sind Weitspannleitungen über die Regelleitungen zu führen.\n2 Eine Regelleitung darf nur in begründeten Ausnahmefällen über eine Weitspannleitung geführt werden. Die Regelleitung muss dabei den Bestimmungen über die mechanische Sicherheit von Weitspannleitungen entsprechen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-91.fr.json","api_md":"/api/v1/ch/lev/art-91.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_91","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-91","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_91","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Starkstromfreileitungen unter sich"}],"id":"ch/lev/art-91","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-91/fr/","kennung":"ch/lev/art-91","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 91","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"072273cd1d8c8b793e69231b5844d1f54dd2e83b7b91b20d64b2d16f747084b2","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-91","titel":"Disposition des lignes","typ":"stelle","url":"/ch/lev/art-91/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 En cas de croisements de lignes aériennes à courant fort, les lignes à grandes portées doivent être placées au-dessus des lignes ordinaires.\n2 Le passage d’une ligne ordinaire au-dessus d’une ligne à grande portée n’est admis que dans les cas de force majeure. La ligne ordinaire doit alors correspondre aux dispositions sur la sécurité mécanique valables pour les lignes à grandes portées."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-91.it.json","api_md":"/api/v1/ch/lev/art-91.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_91","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-91","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_91","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen von Starkstromfreileitungen unter sich"}],"id":"ch/lev/art-91","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-91/it/","kennung":"ch/lev/art-91","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 91","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"6c10aa725dd74d6acd0ae8a82985c6c999a222660a60fd73fb82758acd6b4371","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-91","titel":"Disposizione delle linee","typ":"stelle","url":"/ch/lev/art-91/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Agli incroci tra linee a corrente forte, i conduttori delle linee a lunga portata devono essere disposti al disopra delle linee ordinarie.\n2 Il passaggio di una linea ordinaria sopra una linea a lunga portata è ammesso solo in casi eccezionali motivati. In questi casi, la linea ordinaria deve rispondere alle condizioni in materia di sicurezza imposte alle linee a lunga portata."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-92.de.json","api_md":"/api/v1/ch/lev/art-92.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_92","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-92","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_92","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_4","num":"4. Abschnitt:","titel":"Parallelführungen und Kreuzungen von Kabelleitungen"}],"id":"ch/lev/art-92","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-92/de/","kennung":"ch/lev/art-92","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 92","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"b6f9ee58cc40ea0bbb8e5b3ba627fdfd88646c824dd9bb23cf0a77c137d0bf2c","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-92","titel":"Leitungsführung","typ":"stelle","url":"/ch/lev/art-92/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Parallelführungen und Kreuzungen von Kabelleitungen unter sich sind so anzuordnen, dass sich die Leitungen gegenseitig weder in unzulässiger Weise beeinflussen noch beschädigen.\n2 Die metallenen Umhüllungen parallel geführter oder sich kreuzender Kabelleitungen dürfen sich nur berühren, wenn die Leitungen am gleichen Erdungssystem angeschlossen sind.\n3 Im Erdreich sind die Kabelleitungen mit den kleineren Spannungen über jene mit den grösseren Spannungen zu führen. Ausnahmen sind nur zulässig, wenn die beteiligten Betriebsinhaber ihr Einverständnis dazu gegeben haben.\n4 Parallel geführte Einleiterkabel eines Drehstromstranges gelten als eine einzige Kabelleitung. Kabelschutzrohre aus ferromagnetischem Material sind nur dann zulässig, wenn alle Einleiterkabel im gleichen Rohr verlegt werden.\n5 Hinter dem gleichen Überstromschutzorgan sind parallel geschaltete Kabel nur dann zulässig, wenn sie so verlegt sind, dass sie annähernd gleiche Impedanzen aufweisen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-92.fr.json","api_md":"/api/v1/ch/lev/art-92.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_92","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-92","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_92","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_4","num":"4. Abschnitt:","titel":"Parallelführungen und Kreuzungen von Kabelleitungen"}],"id":"ch/lev/art-92","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-92/fr/","kennung":"ch/lev/art-92","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 92","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"3bffe27c1ab81742cb40e702ccb06b326f00ed5dab321e46a02d5388b8a02145","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-92","titel":"Tracé de la ligne","typ":"stelle","url":"/ch/lev/art-92/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les parallélismes et les croisements de lignes en câbles entre elles doivent être disposés de façon que les lignes ne subissent ni influence ni dommage réciproque inadmissible.\n2 En cas de parallélismes ou de croisements de lignes en câbles, les gaines métalliques ne doivent pouvoir se toucher que si les lignes sont reliées au même système de terre.\n3 Dans le sol, les lignes en câbles de niveaux de tension plus faibles doivent être posées au-dessus des lignes en câbles de niveaux de tension plus élevés. Des exceptions ne sont admises qu’avec l’accord commun des exploitants concernés.\n4 Les câbles unipolaires posés en parallèle et appartenant au même terne à courant triphasé sont considérés comme une seule ligne. Les tuyaux de protection en matériau ferromagnétique sont admis pour de tels câbles uniquement lorsque tous les câbles unipolaires sont posés dans le même tuyau.\n5 Les couplages en parallèle de plusieurs câbles à l’aval du même organe de protection contre les surintensités sont admis uniquement lorsque les câbles sont posés de façon que leurs impédances présentent des valeurs approximativement égales."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-92.it.json","api_md":"/api/v1/ch/lev/art-92.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_92","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-92","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_92","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_4","num":"4. Abschnitt:","titel":"Parallelführungen und Kreuzungen von Kabelleitungen"}],"id":"ch/lev/art-92","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-92/it/","kennung":"ch/lev/art-92","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 92","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"a6cd62bdb061375494eacc7b07af0a09619c705ce281bd50e4d2d4851e80e1ec","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-92","titel":"Tracciato","typ":"stelle","url":"/ch/lev/art-92/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 I parallelismi e gli incroci delle linee in cavo devono essere disposti in modo da evitare interferenze inammissibili o danni reciproci.\n2 Gli involucri metallici delle linee in cavo che corrono parallele o si incrociano possono venire in contatto tra loro soltanto se le linee sono collegate allo stesso sistema di messa a terra.\n3 Nel terreno, le linee in cavo con le tensioni più basse devono essere disposte al disopra di quelle con le tensioni più elevate. Deroghe sono ammesse previo accordo reciproco tra gli esercenti delle due linee.\n4 I cavi unipolari di un sistema trifase disposti parallelamente tra loro sono considerati come un’unica linea in cavo. In questi casi, i tubi protettivi di materiale ferromagnetico sono ammessi solo se tutti i cavi unipolari sono posati nello stesso tubo.\n5 Gli allacciamenti in parallelo di più cavi a valle del medesimo organo di protezione contro le sovracorrenti sono ammessi solo se i cavi sono posati in modo che le loro impedenze siano all’incirca uguali."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-93.de.json","api_md":"/api/v1/ch/lev/art-93.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_93","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-93","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_93","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_4","num":"4. Abschnitt:","titel":"Parallelführungen und Kreuzungen von Kabelleitungen"}],"id":"ch/lev/art-93","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-93/de/","kennung":"ch/lev/art-93","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 93","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"7fc47efacf1104d9ac3647b9ef82f246906ff3f819f3bb7822aa1251c982e3d5","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-93","titel":"Wärmestau und Brandschutz","typ":"stelle","url":"/ch/lev/art-93/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Werden Energiekabelleitungen parallel geführt oder gekreuzt, so sind Massnahmen gegen Schäden infolge von Wärmestauungen zu treffen.\n2 Werden Kabelleitungen in Gebäuden und Kanälen parallel geführt oder gekreuzt, so sind Massnahmen gegen Brandverschleppungen über die Kabelleitungen oder ‑kanäle zu treffen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-93.fr.json","api_md":"/api/v1/ch/lev/art-93.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_93","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-93","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_93","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_4","num":"4. Abschnitt:","titel":"Parallelführungen und Kreuzungen von Kabelleitungen"}],"id":"ch/lev/art-93","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-93/fr/","kennung":"ch/lev/art-93","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 93","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"5f4ec774d07758ff613bc69bc187fa3ee47d701a35b0825ac9898ad09d018043","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-93","titel":"Accumulation de chaleur et prévention d’incendie","typ":"stelle","url":"/ch/lev/art-93/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 En cas de parallélisme ou de croisement de lignes en câbles d’énergie, on prendra les mesures permettant d’assurer l’évacuation de la chaleur.\n2 En cas de parallélisme ou de croisement de lignes en câbles dans des bâtiments ou des caniveaux, on prendra les mesures permettant d’empêcher la propagation d’un incendie éventuel le long des câbles ou des caniveaux."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-93.it.json","api_md":"/api/v1/ch/lev/art-93.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_93","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-93","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_93","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_4","num":"4. Abschnitt:","titel":"Parallelführungen und Kreuzungen von Kabelleitungen"}],"id":"ch/lev/art-93","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-93/it/","kennung":"ch/lev/art-93","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 93","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"4a8c1fd7367cb190f09ee59ce90962cc61e6f8b95908bf520c993dd44797cca1","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-93","titel":"Ristagni termici e protezione antincendio","typ":"stelle","url":"/ch/lev/art-93/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Nei parallelismi ed incroci di cavi adibiti al trasporto di energia vanno presi provvedimenti contro i possibili danni che può provocare il ristagno termico.\n2 Nei parallelismi e negli incroci di più linee in cavo all’interno di fabbricati e di canali vanno presi provvedimenti contro il propagarsi di incendi lungo le linee in cavo o i canali."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-94.de.json","api_md":"/api/v1/ch/lev/art-94.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_94","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-94","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_94","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_4","num":"4. Abschnitt:","titel":"Parallelführungen und Kreuzungen von Kabelleitungen"}],"id":"ch/lev/art-94","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-94/de/","kennung":"ch/lev/art-94","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 94","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"56d743e0902852fafab7506b7c9b034cc7a3ed38cb6c144822e0087e1183c3f8","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-94","titel":"Kabelleitungen für Anlagen mit Schutzfunktionen","typ":"stelle","url":"/ch/lev/art-94/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Kabelleitungen für Anlagen mit wichtigen Schutz- oder Sicherheitsfunktionen dürfen nicht mit Energiekabelleitungen im gleichen Kanal oder Schacht parallel geführt oder gekreuzt werden. Ausnahmen sind zulässig, wenn Anordnung oder Schutzvorkehren eine gegenseitige Gefährdung verhindern."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-94.fr.json","api_md":"/api/v1/ch/lev/art-94.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_94","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-94","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_94","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_4","num":"4. Abschnitt:","titel":"Parallelführungen und Kreuzungen von Kabelleitungen"}],"id":"ch/lev/art-94","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-94/fr/","kennung":"ch/lev/art-94","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 94","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"97b5ef962366edc2c47ddaeb86f7a170fe479d5aebcafa57f57d693446cf083b","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-94","titel":"Lignes en câbles ayant des fonctions protectrices","typ":"stelle","url":"/ch/lev/art-94/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les lignes en câbles affectées à des installations qui revêtent des fonctions importantes de protection et de sécurité ne doivent pas être posées en parallèle avec les lignes en câbles d’énergie ni les croiser dans le même caniveau ou la même chambre à câbles. Des exceptions sont admises lorsque la disposition ou les mesures de protection sont telles qu’il n’existe aucun danger réciproque."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-94.it.json","api_md":"/api/v1/ch/lev/art-94.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_94","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-94","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_94","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_4","num":"4. Abschnitt:","titel":"Parallelführungen und Kreuzungen von Kabelleitungen"}],"id":"ch/lev/art-94","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-94/it/","kennung":"ch/lev/art-94","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 94","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"1a4334dcb137c97fae04b660efee7f9464db4c1766624b9467bf7b64e28eb499","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-94","titel":"Linee in cavo per impianti con funzioni protettive","typ":"stelle","url":"/ch/lev/art-94/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Le linee in cavo per impianti aventi importanti funzioni di protezione o di sicurezza non devono essere posate nello stesso canale o pozzo parallelamente alle linee in cavo destinate al trasporto dell’energia, né incrociare le stesse. Deroghe sono ammesse se la disposizione o le misure protettive sono in grado di impedire la messa in pericolo reciproca."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-95.de.json","api_md":"/api/v1/ch/lev/art-95.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_95","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-95","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_95","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_4","num":"4. Abschnitt:","titel":"Parallelführungen und Kreuzungen von Kabelleitungen"}],"id":"ch/lev/art-95","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-95/de/","kennung":"ch/lev/art-95","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 95","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"c53b63cfddd1537a515547d006ce8be5017b9076ef4c889009da2beda9e55c11","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-95","titel":"Hochspannungskabelleitungen grosser Leistung","typ":"stelle","url":"/ch/lev/art-95/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Hochspannungskabelleitungen mit grossen Erdschluss- bzw. Kurzschlussleistungen dürfen nicht mit anderen Kabelleitungen parallel geführt oder gekreuzt werden, Ausnahmen sind zulässig, wenn Anordnung oder Schutzmassnahmen eine Gefährdung von Personen oder Sachen verhindern."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-95.fr.json","api_md":"/api/v1/ch/lev/art-95.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_95","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-95","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_95","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_4","num":"4. Abschnitt:","titel":"Parallelführungen und Kreuzungen von Kabelleitungen"}],"id":"ch/lev/art-95","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-95/fr/","kennung":"ch/lev/art-95","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 95","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"6f4743b4e0b8d577d4beb6779593bbe65213fbf96f97231cd4035fcb741883b7","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-95","titel":"Lignes en câbles à haute tension à grande puissance","typ":"stelle","url":"/ch/lev/art-95/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les lignes en câbles à haute tension ayant de grandes puissances de court-circuit à la terre ou entre phases ne doivent pas être posées en parallèle avec d’autres lignes en câbles ni les croiser. Des exceptions sont admises lorsque la disposition ou les mesures de protection sont telles qu’il n’existe aucun danger ni pour les personnes ni pour les choses."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-95.it.json","api_md":"/api/v1/ch/lev/art-95.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_95","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-95","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_95","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_4","num":"4. Abschnitt:","titel":"Parallelführungen und Kreuzungen von Kabelleitungen"}],"id":"ch/lev/art-95","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-95/it/","kennung":"ch/lev/art-95","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 95","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"a223f2261f6e7cbf184a18e566bb0c7c6fc9bedf2d24071a9368ba2585082314","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-95","titel":"Linee in cavo ad alta tensione di grande potenza","typ":"stelle","url":"/ch/lev/art-95/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Le linee in cavo ad alta tensione con elevata potenza di cortocircuito tra fasi o verso terra non possono essere tesate parallelamente ad altre linee in cavo né incrociare le stesse. Deroghe sono ammesse se la disposizione o le misure protettive sono in grado di impedire la messa in pericolo di persone o cose."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-96.de.json","api_md":"/api/v1/ch/lev/art-96.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_96","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-96","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_96","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_4","num":"4. Abschnitt:","titel":"Parallelführungen und Kreuzungen von Kabelleitungen"}],"id":"ch/lev/art-96","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-96/de/","kennung":"ch/lev/art-96","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 96","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"4fea8ba173af6fbe6ea808f38b903660dc21beeef9261da3be43d1446b7e3b57","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-96","titel":"Abstände und Abdeckungen","typ":"stelle","url":"/ch/lev/art-96/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Werden Starkstrom- mit Schwachstromkabelleitungen parallel geführt oder gekreuzt, so sind folgende Mindestabstände einzuhalten:\na. in Gebäuden oder in Kabelkanälen 0,005 m pro kV Nennspannung, mindestens jedoch 0,1 m horizontal oder 0,2 m vertikal;\nb. im Erdreich 0,3 m.\n2 Können die Mindestabstände nach Absatz 1 nicht eingehalten werden, so sind zwischen den Kabelleitungen feuerhemmende und elektrisch nicht leitende Abdeckungen anzubringen.\n3 Sind die Kabelleitungen dem gleichen Betriebsinhaber unterstellt oder haben die beteiligten Betriebsinhaber Erstellung, Betrieb und Instandhaltung schriftlich vereinbart, so sind Parallelführungen und Kreuzungen ohne Mindestabstände oder Abdeckungen zulässig bei:\na. werkeigenen und nicht für Anlagen mit wichtigen Schutz- und Sicherheitsfunktionen bestimmten Kabelleitungen in ausschliesslich dem Betrieb elektrischer Anlagen dienenden Gebäuden;\nb. Hochspannungskabelleitungen, die auf einer Länge von weniger als 50 m parallel geführt werden;\nc. Hoch- und Niederspannungskabelleitungen, wenn die Niederspannungskabelleitung ausschliesslich der Übertragung untergeordneter Mess- und Steuersignale dient;\nd. Niederspannungs- und Schwachstromkabelleitungen, die am gleichen Erdungssystem angeschlossen sind;\ne. Niederspannungskabelleitungen, deren äussere Hüllen aus Kunststoff bestehen oder deren metallene Umhüllungen miteinander verbunden und geerdet sind.\n4 Niederspannungs- und Schwachstromleiter dürfen bei entsprechender Isolierung in einem gemeinsamen Kabel zusammengefasst werden, wenn die Leitungen dem gleichen Betriebsinhaber unterstehen.\n5 Bei Parallelführungen und Kreuzungen von Starkstromkabelleitungen unter sich oder mit anderen Leitungen in Betonrohrblöcken ist zwischen den einzelnen Kabelrohren eine Betonschicht von mindestens 4 cm anzubringen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-96.fr.json","api_md":"/api/v1/ch/lev/art-96.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_96","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-96","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_96","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_4","num":"4. Abschnitt:","titel":"Parallelführungen und Kreuzungen von Kabelleitungen"}],"id":"ch/lev/art-96","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-96/fr/","kennung":"ch/lev/art-96","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 96","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"b83fadb75ee97211693b3615dd2605b62aa042fa41d021f9b3a3a64a7bad9f02","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-96","titel":"Distances et revêtements","typ":"stelle","url":"/ch/lev/art-96/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 En cas de parallélisme ou de croisement entre les lignes en câbles à courant fort et des lignes en câble à courant faible, on respectera les distances minimales suivantes:\na. dans les bâtiments ou dans les caniveaux de câbles, 0,005 m par kV de tension nominale, mais au minimum 0,1 m horizontalement ou 0,2 m verticalement;\nb. 0,3 m dans le sol.\n2 Lorsque les distances minimales prescrites à l’al. 1 ne peuvent être respectées, on appliquera entre les lignes en câbles un revêtement électriquement non conducteur destiné à empêcher la propagation du feu.\n3 Lorsque les lignes en câbles sont sous la responsabilité du même exploitant ou que l’établissement, l’entretien et les réparations se font sur la base d’une convention écrite entre les exploitants concernés, les parallélismes et les croisements sont admis sans recouvrement et sans distance minimale pour:\na. les lignes en câbles de l’entreprise elle-même qui sont posées dans des bâtiments servant exclusivement à l’exploitation d’installations électriques et qui ne sont pas affectées à des installations revêtant d’importantes fonctions de protection et de sécurité;\nb. les lignes en câbles à haute tension qui sont en parallèle sur moins de 50 m;\nc. les lignes en câbles, à haute et à basse tension, lorsque la ligne en câble à basse tension sert exclusivement à la transmission de signaux secondaires de mesures et de commande;\nd. les lignes en câbles à basse tension et les lignes en câbles à courant faible reliées au même système de terre;\ne. les lignes en câbles à basse tension possédant des enveloppes extérieures en matière synthétique ou dont les gaines métalliques sont reliées ensemble et mises à la terre.\n4 Les conducteurs de lignes à basse tension et de lignes à courant faible disposant d’une isolation suffisante peuvent être réunis dans un câble commun si ces lignes sont sous la responsabilité du même exploitant.\n5 En cas de parallélisme ou de croisement de lignes en câbles à courant fort entre elles ou avec d’autres lignes dans un bloc de tuyaux en béton, une couche de béton d’au moins 4 cm doit être prévue entre les différents tuyaux."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-96.it.json","api_md":"/api/v1/ch/lev/art-96.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_96","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-96","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_96","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_3","num":"3. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen unter sich"},{"ebene":"section","eid":"tit_2/chap_3/sec_4","num":"4. Abschnitt:","titel":"Parallelführungen und Kreuzungen von Kabelleitungen"}],"id":"ch/lev/art-96","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-96/it/","kennung":"ch/lev/art-96","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 96","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"5579e6e1c2e26e4bcea49b87ce921c7d1d6ad718b53c1c35ff6b9817b6005ea7","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-96","titel":"Distanze e schermature","typ":"stelle","url":"/ch/lev/art-96/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Tra le linee in cavo a corrente forte ed a corrente debole che si incrociano o che corrono parallele, devono essere rispettate le seguenti distanze minime:\na. nei fabbricati o nei canali per cavi: 0,005 m per ogni kV di tensione nominale, ma almeno pari orizzontalmente a 0,1 m, o verticalmente a 0,2 m;\nb. nel terreno: 0,3 m.\n2 Se non possono essere rispettate le distanze minime secondo il capoverso 1, tra le linee in cavo occorre disporre schermature resistenti al fuoco ed elettricamente non conduttrici.\n3 Se le linee in cavo sono sottoposte allo stesso esercente o se gli esercenti interessati si sono accordati per iscritto sulla costruzione, l’esercizio e la manutenzione dei cavi, i parallelismi e gli incroci sono ammessi, senza schermature e senza le distanze minime prescritte:\na. all’interno di costruzioni destinate esclusivamente all’esercizio di impianti elettrici, per le linee in cavo appartenenti all’impresa e non impiegate per installazioni con importanti funzioni di protezione e di sicurezza;\nb. per i parallelismi di linee in cavo ad alta tensione su una lunghezza non superiore a 50 m;\nc. per i parallelismi di linee in cavo ad alta e bassa tensione quando la linea in cavo a bassa tensione serve esclusivamente alla trasmissione di segnali di misurazione e di comando d’importanza secondaria;\nd. per le linee in cavo a bassa tensione e a corrente debole raccordate allo stesso sistema di messa a terra;\ne. per le linee in cavo a bassa tensione il cui involucro esterno è di materiale sintetico oppure quando gli involucri metallici di tutti i cavi sono collegati insieme e messi a terra.\n4 I conduttori delle linee a bassa tensione e delle linee a corrente debole possono essere riuniti, debitamente isolati, in uno stesso cavo quando le linee sono sottoposte allo stesso esercente.\n5 Nei parallelismi e negli incroci in blocchi comuni di cemento a tubi multipli di cavi a corrente forte tra loro o con altre linee, tra i singoli tubi deve esserci uno spessore di cemento di almeno 4 cm."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-97.de.json","api_md":"/api/v1/ch/lev/art-97.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_97","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-97","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_97","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmung"}],"id":"ch/lev/art-97","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-97/de/","kennung":"ch/lev/art-97","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 97","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"7c8cb59c273a42d639bd27d9dc12b65544867f600b5368d4484e26e33bacc152","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-97","titel":"","typ":"stelle","url":"/ch/lev/art-97/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Annäherungen, Parallelführungen und Kreuzungen von elektrischen Leitungen mit anderen Anlagen sind zu vermeiden oder auf möglichst wenige Stellen zu beschränken.\n2 Annäherungen, Parallelführungen oder Kreuzungen von elektrischen Leitungen mit anderen Anlagen sind so anzuordnen, dass sich Leitungen und Anlagen gegenseitig weder in unzulässiger Weise beeinträchtigen noch beschädigen.\n3 Elektrische Leitungen im Bereich von anderen Anlagen müssen so angeordnet werden, dass sich Betrieb und Instandhaltung der Leitungen und der anderen Anlagen gegenseitig nicht beeinträchtigen.\n4 Die Kontrollstelle entscheidet über zusätzliche Schutzmassnahmen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-97.fr.json","api_md":"/api/v1/ch/lev/art-97.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_97","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-97","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_97","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmung"}],"id":"ch/lev/art-97","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-97/fr/","kennung":"ch/lev/art-97","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 97","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"9b6c4db08f596630565a0806c08bb37e3127d555c21d242efb08d6ceeafe148b","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-97","titel":"","typ":"stelle","url":"/ch/lev/art-97/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les rapprochements, les parallélismes et les croisements de lignes électriques avec d’autres installations doivent être évités dans la mesure du possible.\n2 Les rapprochements, les parallélismes ou les croisements de lignes électriques avec d’autres installations doivent être aménagés de façon que les lignes et les installations ne subissent ni préjudice ni dommage réciproque inadmissible.\n3 Les lignes électriques proches d’autres installations doivent être aménagées de façon que leur exploitation et leur entretien ne gênent pas l’exploitation et l’entretien de ces autres installations et réciproquement.\n4 L’organe de contrôle décide des mesures de protection supplémentaires."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-97.it.json","api_md":"/api/v1/ch/lev/art-97.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_97","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-97","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_97","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_1","num":"1. Abschnitt:","titel":"Allgemeine Bestimmung"}],"id":"ch/lev/art-97","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-97/it/","kennung":"ch/lev/art-97","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 97","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"448672129b3621567637fad8f2d2eb359e1d89b61cfb9cbecfe54cad7753aa39","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-97","titel":"","typ":"stelle","url":"/ch/lev/art-97/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le vicinanze, i parallelismi e gli incroci delle linee elettriche con altri impianti devono essere evitati o, per quanto possibile, limitati al minimo.\n2 Le vicinanze, i parallelismi e gli incroci di linee elettriche con altri impianti devono essere disposti in modo che le linee e gli impianti non possano danneggiarsi o influenzarsi reciprocamente in maniera inammissibile.\n3 Le linee elettriche situate nel settore di influenza di altri impianti devono essere disposte in modo da non costituire ostacolo reciproco all’esercizio ed alla manutenzione delle linee e degli impianti.\n4 L’organo di controllo decide in merito alle misure supplementari di protezione."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-98.de.json","api_md":"/api/v1/ch/lev/art-98.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_98","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-98","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_98","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-98","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-98/de/","kennung":"ch/lev/art-98","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 98","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"5dc72191b70a0cf345f9b75860227a38a90e053b72809cad86d54602e84000b4","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-98","titel":"Leitungstragwerke","typ":"stelle","url":"/ch/lev/art-98/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Leitungstragwerke sind so aufzustellen, dass sie auch bei Schiefstellung nicht in das Lichtraumprofil der Bahn hineinragen.\n2 Überführungstragwerke und Tragwerke, die bei Schiefstellung oder beim Umstürzen in das Lichtraumprofil der Bahn hineinragen können, sind:\na. für Ausnahmelast nach Anhang 14 Ziffer 4.3 auszulegen;\nb. mit besonderen Fundamenten nach Artikel 61 Absatz 5 zu versehen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-98.fr.json","api_md":"/api/v1/ch/lev/art-98.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_98","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-98","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_98","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-98","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-98/fr/","kennung":"ch/lev/art-98","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 98","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"44b6c41e73ebbd9c0a198287978d48de6d1152e0aef61a382de5779aee77d268","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-98","titel":"Supports de lignes","typ":"stelle","url":"/ch/lev/art-98/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les supports de lignes doivent être installés de façon qu’en cas d’inclinaison accidentelle ils n’empiètent pas sur le profil d’espace libre de l’installation de traction.\n2 Si des supports de survol ou d’autres supports peuvent empiéter, en cas d’inclinaison ou de chute, sur le profil d’espace libre de l’installation de traction, on devra:\na. les dimensionner pour des charges exceptionnelles conformément à l’annexe 14, ch. 4.3;\nb. prévoir des fondations spéciales conformément à l’art. 61, al. 5."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-98.it.json","api_md":"/api/v1/ch/lev/art-98.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_98","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-98","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_98","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-98","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-98/it/","kennung":"ch/lev/art-98","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 98","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"efebdd4c2de7f1d50ed6687306db94b6d8e30c8f2c4f46d638b95fb12fb457d2","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-98","titel":"Sostegni delle linee","typ":"stelle","url":"/ch/lev/art-98/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 I sostegni delle linee vanno messi in opera in modo che non possano penetrare, nemmeno in posizione inclinata, all’interno della sagoma di spazio libero della ferrovia.\n2 I sostegni delle linee sovrapassanti ed i sostegni che possono penetrare all’interno della sagoma di spazio libero della ferrovia in seguito ad inclinazione o a caduta devono:\na. essere dimensionati per i carichi eccezionali secondo l’appendice 14, cifra 4.3;\nb. essere dotati di fondazioni speciali secondo l’articolo 61 capoverso 5."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-99.de.json","api_md":"/api/v1/ch/lev/art-99.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_99","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-99","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_99","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-99","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-99/de/","kennung":"ch/lev/art-99","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 99","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"27d898dc15b830cc028e304969eb8ea892931bf830c8fe695a4495be37d35cd8","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-99","titel":"Abstand bei Annäherungen und Parallelführungen","typ":"stelle","url":"/ch/lev/art-99/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Der Mindestabstand zwischen elektrischen Leitungen und Tragwerken oder Leitern der Fahrleitungsanlage (inkl. Spurhalter) und Schutzseilen muss betragen:\na. mindestens 3 m plus 0,01 m pro kV der höchsten Nennspannung;\nb. 0,01 m pro kV Nennspannung, mindestens aber 1 m bei Windauslenkung der Leiter.\n2 Gemeinsame Tragwerke sind zulässig, wenn der Abstand der Ausleger und Joche der Fahrleitungsanlage oder des Mastschaftes der gemeinsamen Tragwerke zu den Leitern der parallel geführten Leitung mindestens 3 m plus 0,01 m pro kV der höchsten Nennspannung beträgt. Weisen die Leitungen getrennte Erdungssysteme auf, so sind sämtliche Isolatoren für die höchste Nennspannung zu bemessen.\n3 Müssen Leiter, die nicht dem Bahnbetrieb dienen, über Fahrleitungsanlagen angelegt werden, so legt die Kontrollstelle die zu treffenden Schutzmassnahmen fest.\n4 Kabelleitungen, ausgenommen Lichtwellenleiter ohne metallene Teile, die nicht dem Bahnbetrieb dienen, müssen ausserhalb der Gleisanlage und den zugehörigen Leitungstragwerken für die Bahnstromversorgung verlegt werden. Dabei muss der Abstand des Kabels zur äusseren Schiene mindestens 1,3 m betragen.\n5 Die Kontrollstellen können für Kabelleitungen kleinere Abstände oder die Verlegung zwischen Gleiskörper und Tragwerkfundamenten bewilligen, wenn:\na. keine gegenseitigen Beeinträchtigungen zu befürchten sind; oder\nb. die Bahn nicht auf unabhängigem Bahnkörper verkehrt; oder\nc. die Bahn auf unabhängigem Bahnkörper verkehrt und die beteiligten Betriebsinhaber ihr Einverständnis dazu gegeben haben."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-99.fr.json","api_md":"/api/v1/ch/lev/art-99.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_99","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-99","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_99","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-99","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-99/fr/","kennung":"ch/lev/art-99","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 99","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"8ea932a8ded1fa3f8ee51aa30a75340860cd920769480cc38d8c58d0722ccca7","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-99","titel":"Distance en cas de rapprochement ou de parallélisme","typ":"stelle","url":"/ch/lev/art-99/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 La distance minimale entre les lignes électriques et les supports ou les conducteurs d’installations de lignes de contact, bras de retenue inclus, et les cordes de protection doit être:\na. au minimum de 3 m plus 0,01 m par kV de la tension nominale la plus élevée;\nb. de 0,01 m par kV de tension nominale, mais jamais inférieure à 1 m en cas de déviation du conducteur due au vent.\n2 Les supports communs sont admis lorsque la distance entre les consoles de support, les jougs d’installations de lignes de contact ou les supports communs et les conducteurs de la ligne parallèle est d’au moins 3 m plus 0,01 m par kV de la tension nominale la plus élevée. Lorsque les lignes disposent de systèmes de mise à terre séparés, on dimensionnera tous les isolateurs pour la tension nominale la plus élevée.\n3 Lorsque des conducteurs ne servant pas à l’exploitation de l’installation de traction doivent être placés au-dessus d’installations de lignes et contact, l’organe de contrôle fixe les mesures de protection adéquates.\n4 Les lignes en câbles, exception faite des conducteurs à fibres optiques sans partie métallique, qui ne servent pas à l’exploitation de l’installation de traction, doivent être posées en dehors du domaine des voies et des supports de ligne servant à l’alimentation électrique de l’installation de traction. De plus, la distance doit être de 1,3 m au moins entre le câble et le rail extérieur.\n5 Pour les lignes en câbles, les organes de contrôle peuvent autoriser des distances inférieures ou une pose entre la voie et les fondations des supports:\na. lorsque cela n’entraîne aucun préjudice réciproque; ou\nb. que les installations de traction sont établies en chaussée; ou encore\nc. que les installations de traction sont sur une plate-forme indépendante et que les exploitants concernés ont donné leur accord."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-99.it.json","api_md":"/api/v1/ch/lev/art-99.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_99","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-99","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_99","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-99","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-99/it/","kennung":"ch/lev/art-99","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 99","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"decc5615a6baef2da15c8c03329edb733c36c4459d74c00ae17e6a4131488758","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-99","titel":"Distanze nelle vicinanze e nei parallelismi","typ":"stelle","url":"/ch/lev/art-99/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 La distanza minima tra le linee elettriche ed i sostegni o tra i conduttori delle linee di trazione (compresi i pendini del filo di contatto) e le funi di protezione deve essere uguale:\na. ad almeno 3 m più 0,01 m per ogni kV della tensione nominale più alta;\nb. a 0,01 m per ogni kV di tensione nominale, ma in ogni caso non inferiore ad 1 m in presenza di inclinazione dei conduttori sotto la spinta del vento.\n2 I sostegni in comune sono ammessi se la distanza tra le mensole ed i portali della linea di trazione, o tra lo stelo dei sostegni in comune, ed i conduttori della linea parallela, è almeno pari a 3 m più 0,01 m per ogni kV della tensione nominale più alta. Se le linee dispongono di sistemi separati di messa a terra, tutti gli isolatori vanno dimensionati per la tensione nominale più alta.\n3 Se dei conduttori che non servono all’esercizio ferroviario devono essere disposti al disopra della linea di trazione, l’organo di controllo fissa le misure di protezione da adottare.\n4 Le linee in cavo, ad esclusione dei conduttori a fibre ottiche senza parti metalliche, che non servono all’esercizio ferroviario devono essere posate all’esterno della sede ferroviaria e dei sostegni dei conduttori per l’alimentazione in energia della ferrovia. In tal caso, la distanza del cavo dalla rotaia più esterna deve essere ameno pari a 1,3 m.\n5 Per quanto concerne le linee in cavo, gli organi di controllo possono autorizzare distanze minori o la posa tra la massicciata e le fondazioni dei sostegni quando:\na. non ci sia da temere nessuna interferenza reciproca;\nb. la ferrovia non dispone di una sede propria;\nc. la ferrovia viaggia su sede propria, e gli esercenti interessati hanno dato il loro accordo."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-100.de.json","api_md":"/api/v1/ch/lev/art-100.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_100","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-100","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_100","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-100","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-100/de/","kennung":"ch/lev/art-100","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 100","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"3ae1c641de94295205ac30107c424902b9cf76422261d34049fcfceb1624af2f","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-100","titel":"Kreuzungen von Bahnen mit Fahrleitung","typ":"stelle","url":"/ch/lev/art-100/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Schwachstrom- und Niederspannungsleitungen sind unter den Gleisen durchzuführen.\n2 Soll ausnahmsweise eine Schwachstrom- oder eine Niederspannungsfreileitung über die Bahn geführt werden, so entscheidet die Kontrollstelle:\na. über die Zulässigkeit;\nb. über die zu treffenden Schutzmassnahmen.\n3 Beleuchtungskörper und ihre Zuleitungen an Tragelementen, die von der Fahrleitungsanlage unabhängig sind, müssen im Überführungsbereich der Fahrleitung:\na. eine verstärkte Isolation aufweisen; und\nb. gegen nicht-bahngeerdete Tragwerke so isoliert sein, dass sie diese nicht unter gefährliche Spannung setzen, wenn sie die Fahrdrähte berühren."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-100.fr.json","api_md":"/api/v1/ch/lev/art-100.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_100","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-100","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_100","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-100","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-100/fr/","kennung":"ch/lev/art-100","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 100","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"6cc9398abc0a0f6473c902c213a082cc69b51238370ec1c9aba9bbda2a052e8c","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-100","titel":"Croisements avec des installations de traction munies de lignes de contact","typ":"stelle","url":"/ch/lev/art-100/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les lignes à courant faible et les lignes à basse tension doivent être placées sous les voies.\n2 Lorsqu’une ligne aérienne à courant faible ou à basse tension doit exceptionnellement survoler l’installation de la ligne de contact, l’organe de contrôle décide:\na. si le survol est admissible;\nb. des mesures de protection adéquates.\n3 Les luminaires et leurs lignes d’alimentation montés sur des éléments porteurs indépendants de l’installation de la ligne de contact doivent, dans la zone de survol de la ligne de contact:\na. avoir une isolation renforcée; et\nb. être isolés des supports non reliés à la terre de l’installation de traction afin qu’en cas de chute de l’installation d’éclairage sur les fils de contact les supports ne soient pas mis sous une tension dangereuse."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-100.it.json","api_md":"/api/v1/ch/lev/art-100.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_100","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-100","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_100","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-100","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-100/it/","kennung":"ch/lev/art-100","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 100","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"ac7cb7fd8583d17ef1895212e189b8d13164531b6a40ea356d9526e869e926cc","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-100","titel":"Incroci con le ferrovie dotate di linea di contatto","typ":"stelle","url":"/ch/lev/art-100/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le linee a corrente debole e le linee a bassa tensione devono passare sotto i binari.\n2 Se, in via eccezionale, una linea aerea a corrente debole o una linea aerea a bassa tensione deve passare sopra la ferrovia, l’organo di controllo decide in merito:\na. all’ammissibilità di una tale soluzione;\nb. alle misure di protezione da adottare.\n3 Le sorgenti luminose ed i loro fili di alimentazione portati da sostegni indipendenti dall’impianto elettrico di trazione devono, nel settore di passaggio al disopra della linea di contatto:\na. disporre di una isolazione rinforzata; e\nb. essere isolati, rispetto ai sostegni non collegati alla terra della ferrovia, in modo tale da non mettere questi sotto tensioni pericolose nel caso che tocchino i fili di contatto."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-101.de.json","api_md":"/api/v1/ch/lev/art-101.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_101","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-101","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_101","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-101","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-101/de/","kennung":"ch/lev/art-101","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 101","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"7246490aac2ba86ee38eb45f3b778ad5ebbf66fef939f94f3f912a09ea28da42","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-101","titel":"Abstand bei Kreuzungen","typ":"stelle","url":"/ch/lev/art-101/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Kreuzen elektrische Leitungen Bahnen mit Fahrleitungen, so sind die Abstände so gross zu halten, dass ein gefahrloses Arbeiten an den Fahrleitungsanlagen möglich ist.\n2 Der Abstand zwischen übergeführten blanken Leitern und der Fahrleitungsanlage muss beim grössten Leiterdurchhang mindestens 3 m plus 0,01 m pro kV der höchsten Nennspannung plus 0,02 m pro Meter Abstand zwischen der Kreuzungsstelle und dem näher liegenden Überführungstragwerk betragen (Anhang 18).\n3 Bei Normalspurbahnen mit Wechselstrombetrieb ist in jedem Fall für die übergeführten Leiter eine Höhe von mindestens 14 m über der Schienenoberkante einzuhalten.\n4 Der Abstand zwischen übergeführten Leitern und Fahrleitungen von Fahrzeugen, deren Stromabnehmer sich leicht von der Fahrleitung lösen können, (z. B. Stangenstromabnehmer von Trolleybussen) bestimmt sich nach Anhang 6 Ziffer 2.1.2, muss aber mindestens 1,5 m betragen. Der Abstand wird zwischen übergeführten Leitern und der höchstmöglichen Stellung des Stromabnehmers gemessen. Kann er nicht eingehalten werden, sind Massnahmen, namentlich gegen das Anheben der Stromabnehmer, zu treffen.\n5 Bei bodennahen Stromschienen muss der Abstand zwischen übergeführten Leitern und Schienenoberkante 7 m plus 0,01 m pro kV der Nennspannung betragen.\n6 Übersteigt die für die Bahn massgebende Grenzlinie der festen Anlagen (gemäss Lichtraumprofil) die Höhe von 4 m, so ist der Mindestabstand nach Absatz 5 um diese Differenz zu vergrössern."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-101.fr.json","api_md":"/api/v1/ch/lev/art-101.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_101","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-101","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_101","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-101","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-101/fr/","kennung":"ch/lev/art-101","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 101","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"2ebabd452ee0f49edb839ffb2a3ce7b855837e490fa80ee0b0a362dde320aae7","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-101","titel":"Distance en cas de croisement","typ":"stelle","url":"/ch/lev/art-101/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Lorsque des lignes électriques croisent des installations de traction munies de lignes de contact, les distances doivent être maintenues assez grandes pour permettre un travail sans danger sur les installations de la ligne de contact.\n2 La distance entre l’installation de la ligne de contact et les conducteurs nus la survolant, mesurée avec la flèche maximale de ces derniers, doit être d’au moins 3 m plus 0,01 m par kV de la tension nominale la plus élevée, plus 0,02 m par mètre de distance entre le point de croisement et le support de la ligne supérieure le plus proche (annexe 18).\n3 On maintiendra en outre, entre le niveau supérieur des rails et les conducteurs les survolant, une distance verticale d’au moins 14 m pour les chemins de fer à voie normale et courant alternatif.\n4 La distance entre les lignes de contact des véhicules dont la prise de courant peut facilement dérailler du fil de contact (par exemple, pour les perches de trolleybus) et les conducteurs les survolant se calcule selon l’annexe 6, ch. 2.1.2. Elle doit être mesurée entre les conducteurs en survol et la position la plus élevée pouvant être atteinte par la prise de courant. Elle ne doit pas être inférieure à 1,5 m. Si cela s’avère impossible, on prendra des mesures notamment afin d’empêcher que la prise de courant n’atteigne une position trop élevée.\n5 Lorsqu’un rail conducteur proche du sol remplace la ligne de contact, la distance minimale entre le niveau supérieur du rail et les conducteurs le survolant doit être de 7 m, plus 0,01 m par kV de tension nominale.\n6 Au cas où la hauteur limite déterminante de 4 m des installations fixes de l’installation de traction (selon le profil d’espace libre) est dépassée, la distance minimale prescrite à l’al. 5 doit être majorée de la différence."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-101.it.json","api_md":"/api/v1/ch/lev/art-101.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_101","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-101","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_101","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-101","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-101/it/","kennung":"ch/lev/art-101","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 101","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"c37c1da239687776ca93aee315ec15568a1b26f64542b5ed9202f8215be5b39b","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-101","titel":"Distanze agli incroci","typ":"stelle","url":"/ch/lev/art-101/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Agli incroci con ferrovie dotate di linea di contatto, le distanze devono essere fissate in modo che sia possibile lavorare senza pericolo agli impianti di trazione elettrica.\n2 La distanza tra i conduttori nudi sovrapassanti e l’impianto di trazione elettrica deve essere, in presenza della freccia massima, almeno pari a 3 m, più 0,01 m per ogni kV della tensione nominale più elevata e più 0,02 m per ogni metro di distanza del punto di incrocio dal più vicino sostegno della linea sovrapassante (appendice 18).\n3 Per le ferrovie a scartamento normale alimentate a corrente alternata occorre in ogni caso rispettare una altezza di 14 m tra i conduttori sovrapassanti e la testa della rotaia.\n4 Per le linee di trazione nelle quali l’organo di presa di corrente del rotabile può facilmente allontanarsi dal filo di contatto (ad es. trolley dei filobus), la distanza tra i conduttori sovrapassanti e la linea di contatto si determina conformemente all’appendice, cifra 2.1.2, ma deve essere almeno pari a 1,5 m. La distanza è misurata tra i conduttori sovrapassanti e la posizione più elevata dell’organo di presa di corrente. Se non può essere rispettata, occorre applicare misure atte a limitare l’escursione verso l’alto dell’organo di presa di corrente.\n5 Quando la linea di contatto ha la forma di una rotaia posta in prossimità del suolo, la distanza tra i conduttori sovrapassanti e la testa della rotaia deve essere pari a 7 m più 0,01 m per ogni kV di tensione nominale.\n6 Se la sagoma limite degli impianti fissi determinante per la ferrovia (conformemente alla sagoma di spazio libero) ha un altezza superiore a 4 m, la distanza minima secondo il capoverso 5 deve essere aumentata di questa differenza."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-102.de.json","api_md":"/api/v1/ch/lev/art-102.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_102","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-102","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_102","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-102","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-102/de/","kennung":"ch/lev/art-102","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 102","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"87d4faa14694005f97fc923c8870f1dd590238869411aea6b055123fc4781c4e","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-102","titel":"Kreuzungen von Bahnen ohne Fahrleitung","typ":"stelle","url":"/ch/lev/art-102/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Kreuzen elektrische Leitungen Bahnen ohne Fahrleitung, so muss der Abstand zwischen den übergeführten Leitern und der Schienenoberkante mindestens 7 m plus 0,01 m pro kV der Nennspannung betragen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-102.fr.json","api_md":"/api/v1/ch/lev/art-102.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_102","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-102","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_102","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-102","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-102/fr/","kennung":"ch/lev/art-102","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 102","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"6dc43fbcbf042d13a51fa69495ad43863e5284f5f98a48995204c3a6a4bf0ff5","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-102","titel":"Croisement avec des installations de traction sans ligne de contact","typ":"stelle","url":"/ch/lev/art-102/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"La distance entre le niveau supérieur des rails et les conducteurs les survolant doit être au minimum de 7 m plus 0,01 m par kV de tension nominale."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-102.it.json","api_md":"/api/v1/ch/lev/art-102.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_102","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-102","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_102","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-102","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-102/it/","kennung":"ch/lev/art-102","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 102","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"6a835fd958f0eab39356ccec71bd16a8f902c116568071f13e7c5f7342decd0f","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-102","titel":"Incroci con ferrovie senza linea di contatto","typ":"stelle","url":"/ch/lev/art-102/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Se le linee elettriche incrociano ferrovie senza linea di contatto, l’altezza sulla testa della rotaia dei conduttori sovrapassanti deve essere almeno pari a 7 m più 0,01 m per ogni kV di tensione nominale."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-103.de.json","api_md":"/api/v1/ch/lev/art-103.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_103","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-103","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_103","fussnoten":[{"marker":"36","nummer":36,"text":"SR 742.141.1"},{"marker":"37","nummer":37,"text":"Fassung gemäss Beilage 2 Ziff. II 4 der V vom 16. Nov. 2011, in Kraft seit 1. Juli 2012 (AS 2011 6233)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-103","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-103/de/","kennung":"ch/lev/art-103","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 103","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"0c01038fc0a7cc80cdad323e4585939d68ab87b0f3caf77e0065f3a4a2b2b331","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-103","titel":"Kabelunterführungen","typ":"stelle","url":"/ch/lev/art-103/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Die Unterführung von Kabelleitungen unter Bahnen darf die Festigkeit des Bahnkörpers nicht beeinträchtigen und kein Hindernis für Anlagen darstellen, die dem Bahnbetrieb dienen.\n2 Die Abstände zwischen Kabelleitung und Schienenunterkante müssen betragen:\na. mindestens 1,3 m bei Gleisen auf unabhängigem Bahnkörper;\nb. mindestens 0,7 m bei Gleisen in Strassen oder auf allgemein befahrbarem Gebiet.\n3 Der mechanische Kabelschutz darf die Eigenschaften des Oberbaus nicht beeinträchtigen.\n4 Metallene Schutzverkleidungen und Kabelarmaturen im Nahbereich der Gleise müssen den Artikeln 42–46 der Eisenbahnverordnung vom 23. November 1983 entsprechen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-103.fr.json","api_md":"/api/v1/ch/lev/art-103.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_103","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-103","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_103","fussnoten":[{"marker":"35","nummer":35,"text":"RS 742.141.1"},{"marker":"36","nummer":36,"text":"Nouvelle teneur selon l’annexe 2 ch. II 4 de l’O du 16 nov. 2011, en vigueur depuis le 1er juil. 2012 (RO 2011 6233)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-103","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-103/fr/","kennung":"ch/lev/art-103","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 103","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"5a7680f5c84534f1578795f83bef447d46b662a27576c586a1a71b6cf6362801","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-103","titel":"Passage de câbles au-dessous des installations de traction","typ":"stelle","url":"/ch/lev/art-103/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Le passage de lignes en câbles au-dessous des installations de traction ne doit pas compromettre la solidité de la plate-forme ni entraver l’exploitation de l’installation de traction.\n2 Les distances entre les lignes en câbles et le niveau inférieur des rails doivent être de:\na. 1,3 m au moins pour les voies avec plate-forme indépendante;\nb. 0,7 m au moins pour les voies établies en chaussée.\n3 La protection mécanique des câbles ne doit pas influencer la qualité des superstructures.\n4 Les revêtements de protection métalliques et les armatures métalliques de câbles au voisinage des voies sont soumis aux art. 42 à 46 de l’ordonnance du 23 novembre 1983 sur les chemins de fer."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-103.it.json","api_md":"/api/v1/ch/lev/art-103.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_103","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-103","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_103","fussnoten":[{"marker":"37","nummer":37,"text":"RS 742.141.1"},{"marker":"38","nummer":38,"text":"Nuovo testo giusta dell’annesso 2 cifra II n. 4 dell’O del 16 nov. 2011, in vigore dal 1° lug. 2012 (RU 2011 6233)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-103","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-103/it/","kennung":"ch/lev/art-103","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 103","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"10f2a65b8a6c0051da68020f2d9f895e9a6b47c1ccd32f27c30735605aef11c6","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-103","titel":"Sottopassaggio di cavi","typ":"stelle","url":"/ch/lev/art-103/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Gli attraversamenti di linee in cavo sotto le sedi ferroviarie non devono pregiudicare la stabilità della sottostruttura e non costituire un ostacolo per gli impianti destinati all’esercizio ferroviario.\n2 Le distanze tra le linee in cavo e la suola della rotaia devono essere pari:\na. ad almeno 1,3 m per i binari su sede propria;\nb. ad almeno 0,7 m per i binari posati su strada o su sede aperta al traffico.\n3 La protezione meccanica del cavo non deve pregiudicare le proprietà della sovrastruttura ferroviaria.\n4 In prossimità dei binari, i mantelli protettivi metallici e le armature dei cavi devono soddisfare gli articoli 42‒46 dell’ordinanza del 23 novembre 1983 sulle ferrovie."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-104.de.json","api_md":"/api/v1/ch/lev/art-104.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_104","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-104","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_104","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-104","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-104/de/","kennung":"ch/lev/art-104","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 104","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"c10215b3f3ed4bb6acdd1218b9486b738e939be03f0b16e0edbbb3bddb045e47","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-104","titel":"Unterführung von Hochspannungsfreileitungen unter Bahnbrücken","typ":"stelle","url":"/ch/lev/art-104/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Wird eine Hochspannungsfreileitung unter einer Bahnbrücke hindurchgeführt, so müssen Leiter, Erdleiter und Luftkabel zu Konstruktionsteilen und Betriebseinrichtungen der Brücke folgende Mindestabstände aufweisen:\na. einen Direktabstand von mindestens 2,5 m plus 0,01 m pro kV Nennspannung bei 0 °C Leitertemperatur ohne Zusatzlast;\nb. einen Horizontalabstand von mindestens 1,5 m plus 0,01 m pro kV Nennspannung für Leiter bei Windauslenkung.\n2 Dient die Brücke auch dem allgemeinen Fussgängerverkehr oder beträgt der Horizontalabstand zwischen der Brücke und einem Unterführungstragwerk weniger als 25 m, so ist an der Brücke ein 1,8 m hohes Schutzgitter mit Warnzeichen anzubringen, die auf die Gefahren beim Berühren von spannungsführenden Teilen hinweisen. Dieses Gitter muss beidseitig mindestens 2 m über die Leitungsbreite hinausreichen.\n3 Instandhaltungsarbeiten, Schneeräumungen und Reparaturen an und auf der Brücke dürfen durch die Hochspannungsleitung nicht beeinträchtigt werden. Sie sind schriftlich zu vereinbaren."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-104.fr.json","api_md":"/api/v1/ch/lev/art-104.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_104","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-104","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_104","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-104","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-104/fr/","kennung":"ch/lev/art-104","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 104","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"07ce4af9a0641b919270fe9bc4c22a61c9a2f3346c8b84f818ac2356957bb34a","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-104","titel":"Passage des lignes aériennes à haute tension sous les ponts des installations de traction","typ":"stelle","url":"/ch/lev/art-104/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Lorsqu’une ligne aérienne à haute tension passe sous un pont d’une installation de traction, on respectera entre les conducteurs, les conducteurs de terre, les câbles aériens et les éléments de construction ou les installations d’exploitation du pont:\na. une distance directe minimale de 2,5 m + 0,01 m par kV de tension nominale pour une température de 0° C sans surcharge;\nb. une distance horizontale minimale de 1,5 m + 0,01 m par kV de tension nominale en cas de déviations du conducteur dues au vent.\n2 Si le pont est ouvert aux piétons ou si la distance horizontale entre le pont et le support de la ligne passant en dessous est inférieure à 25 m, on posera sur le pont un treillis de protection d’une hauteur de 1,8 m, muni de signaux avertissant du danger encouru à toucher les éléments sous tension. Ce treillis devra dépasser de 2 m au moins de chaque côté de l’emprise de la ligne.\n3 La présence de la ligne à haute tension ne doit être préjudiciable ni au déblaiement de la neige ni aux travaux d’entretien ou de réparation du pont. Ces travaux doivent être exécutés sur la base de conventions écrites."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-104.it.json","api_md":"/api/v1/ch/lev/art-104.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_104","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-104","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_104","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_2","num":"2. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Eisenbahn-, Standseilbahn- und Trolleybusanlagen (Bahnen)"}],"id":"ch/lev/art-104","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-104/it/","kennung":"ch/lev/art-104","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 104","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"f76ba8d95493bd3b178736d33365a0008a56624ca78a4929e2080dc40c6e8ff1","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-104","titel":"Passaggi di linee aeree ad alta tensione sotto i ponti ferroviari","typ":"stelle","url":"/ch/lev/art-104/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Nel caso che una linea aerea ad alta tensione debba sottopassare un ponte ferroviario, i conduttori, i conduttori di terra ed i cavi aerei devono presentare, rispetto alle parti costruttive ed ai dispositivi d’esercizio del ponte, le seguenti distanze minime:\na. una distanza diretta pari ad almeno 2,5 m + 0,01 m per ogni kV di tensione nominale, per una temperatura dei conduttori di 0° C ed in assenza di sovraccarico;\nb. una distanza orizzontale pari ad almeno 1,5 m + 0,01 m per ogni kV di tensione nominale, in presenza di inclinazione dei conduttori dovuta alla spinta del vento.\n2 Se il ponte è aperto al traffico pedonale oppure la distanza orizzontale tra il ponte ed un sostegno della linea sottopassante è inferiore a 25 m, è necessario apporre una rete di protezione alta 1,8 m con cartelli d’avvertimento che accennano al pericolo di toccare parti sotto tensione. Detta rete deve estendersi per almeno 2 m da ambedue i lati della linea sottopassante, oltre la larghezza della stessa.\n3 I lavori di manutenzione, lo sgombero della neve e le riparazioni al e sul ponte non devono essere pregiudicati dalla presenza delle linee ad alta tensione. Essi devono essere oggetto di una convenzione scritta."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-105.de.json","api_md":"/api/v1/ch/lev/art-105.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_105","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-105","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_105","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-105","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-105/de/","kennung":"ch/lev/art-105","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 105","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"9e57d2695149623b3f0d35ad4da1833a74861265549d235bea1dd058dd006c10","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-105","titel":"Leitungstragwerke","typ":"stelle","url":"/ch/lev/art-105/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Wo Leitungstragwerke durch Schiefstellung oder Umsturz den Seilbahnbetrieb unmittelbar gefährden können, sind Stützmasten nicht zulässig.\n2 Solche Tragwerke müssen den Anforderungen für Sondertragmasten (Anhang 14 Ziff. 4.3) entsprechen und mit besonderen Fundamenten nach Artikel 61 Absatz 5 ausgerüstet sein."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-105.fr.json","api_md":"/api/v1/ch/lev/art-105.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_105","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-105","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_105","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-105","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-105/fr/","kennung":"ch/lev/art-105","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 105","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"b988561a3671f9b13221797423a446d9f861b5498fd5f5f6d9e5963896daeb8e","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-105","titel":"Supports de lignes","typ":"stelle","url":"/ch/lev/art-105/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les supports d’appui ne sont pas admis là où ils peuvent, en cas de chute ou d’inclinaison accidentelle, mettre directement en danger l’exploitation du téléphérique.\n2 Les supports de lignes doivent satisfaire aux exigences valables pour les supports porteurs spéciaux conformément à l’annexe 14, ch. 4.3, et être munis de fondations spéciales conformément à l’art. 61, al. 5."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-105.it.json","api_md":"/api/v1/ch/lev/art-105.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_105","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-105","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_105","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-105","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-105/it/","kennung":"ch/lev/art-105","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 105","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"60bca13e14ae48f3e282bfb671fce683c02417cc57b1a5ee4441c749e48af862","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-105","titel":"Sostegni delle linee elettriche","typ":"stelle","url":"/ch/lev/art-105/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Non sono ammessi sostegni ordinari che, in seguito a inclinazione o caduta, potrebbero mettere direttamente in pericolo l’esercizio dell’impianto di trasporto a fune.\n2 Questi sostegni devono soddisfare i requisiti richiesti ai sostegni portanti speciali (appendice 14, cifra 4.3) ed essere dotati di fondazioni speciali secondo l’articolo 61 capoverso 5."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-106.de.json","api_md":"/api/v1/ch/lev/art-106.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_106","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-106","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_106","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-106","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-106/de/","kennung":"ch/lev/art-106","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 106","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"81bcacd93891d47650e0795051853514efbf5c7b977b379cbf6cc507d1190d15","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-106","titel":"Erdungen","typ":"stelle","url":"/ch/lev/art-106/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Die der Annäherungs- und Kreuzungsstelle zunächst liegenden Stützen und die Stationen der Luftseilbahn sowie allfällige Schutzkonstruktionen sind zu erden.\n2 Schutzkonstruktionen über Hochspannungsfreileitungen dürfen nicht in metallener Verbindung mit Teilen der Luftseilbahn stehen.\n3 Alle Erdungen, Fundamente und Stützen von Luftseilbahnen und darüber angebrachten Schutzkonstruktionen müssen sich ausserhalb der gefährlichen Einflussbereiche der Erdungen von Hochspannungstragwerken befinden.\n4 Sind Verschleppung von Potentialdifferenzen über die Seilbahnanlage möglich, so ordnen die Kontrollstellen die Schutzmassnahmen an."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-106.fr.json","api_md":"/api/v1/ch/lev/art-106.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_106","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-106","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_106","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-106","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-106/fr/","kennung":"ch/lev/art-106","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 106","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"cd06be7e1533e4c63e7cb3908fca7fdc4a6fb5bdd5aba48f03a95ad542f670e2","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-106","titel":"Mises à la terre","typ":"stelle","url":"/ch/lev/art-106/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les pylônes d’un téléphérique qui sont situés dans le voisinage immédiat de rapprochements ou de croisements, mais aussi les stations du téléphérique et les éventuelles constructions protectrices doivent être mis à la terre.\n2 Les constructions protectrices au-dessus de lignes aériennes à haute tension ne doivent pas être reliées galvaniquement aux éléments du téléphérique.\n3 Les mises à la terre, les fondations et les pylônes de téléphériques ainsi que les constructions de protection placées au-dessus doivent tous se trouver en dehors des zones d’influences dangereuses des mises à la terre des supports de la ligne aérienne à haute tension.\n4 Lorsque des migrations de potentiels sont susceptibles d’être engendrées par l’installation du téléphérique, les organes de contrôle ordonnent les mesures de protection adéquates."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-106.it.json","api_md":"/api/v1/ch/lev/art-106.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_106","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-106","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_106","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-106","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-106/it/","kennung":"ch/lev/art-106","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 106","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"a6ea3e42d307d04b9283302e445e1a5f609f19274490e9799502d845e7d1bd9a","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-106","titel":"Messe a terra","typ":"stelle","url":"/ch/lev/art-106/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 I sostegni più prossimi ai punti di vicinanza e di incrocio, nonché le stazioni delle funivie e le eventuali costruzioni protettive, devono essere messi a terra.\n2 Le costruzioni protettive al disopra delle linee aeree ad alta tensione non devono essere in contatto metallico con parti della funivia.\n3 Tutte le terre, le fondazioni, i sostegni della funivia e le costruzioni protettive sopra la stessa devono trovarsi all’esterno della zona di influenza pericolosa intorno alle terre dei sostegni della linea aerea ad alta tensione.\n4 Se vi è possibilità di trasferimento di differenza di potenziale lungo l’impianto di trasporto a fune, gli organi di controllo ordinano le misure di protezione necessarie."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-107.de.json","api_md":"/api/v1/ch/lev/art-107.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_107","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-107","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_107","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-107","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-107/de/","kennung":"ch/lev/art-107","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 107","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"f71f088fda24be1a09c3032a134d49084fc75548e72978f6105541b3347e0f6d","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-107","titel":"Skilifte, Materialseilbahnen","typ":"stelle","url":"/ch/lev/art-107/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Die Kontrollstellen entscheiden über die Zulässigkeit von Annäherungen, Parallelführungen und Kreuzungen von elektrischen Freileitungen mit Skiliften, Materialseilbahnen, Kran- und Reistseilen oder ähnlichen Anlagen.\n2 Sie bestimmen die zu treffenden Schutzmassnahmen. Zu berücksichtigen ist dabei namentlich das Aufschnellen der Transportseile beim Abfall von Lasten."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-107.fr.json","api_md":"/api/v1/ch/lev/art-107.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_107","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-107","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_107","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-107","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-107/fr/","kennung":"ch/lev/art-107","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 107","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"c61c9b037972c7f48646a2793423ddf2c47e189a323719473019e7636c533f42","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-107","titel":"Téléskis, téléphériques de transport de matériel","typ":"stelle","url":"/ch/lev/art-107/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 En cas de rapprochement, de parallélisme ou de croisement de lignes aériennes électriques avec des téléskis, des téléphériques de transport de matériel, des câbles de blondins, des câbles de débardage ou des installations similaires, les organes de contrôle décident si la disposition projetée est admissible.\n2 Ils décident des mesures de protection adéquates en tenant notamment compte du rebondissement vers le haut des câbles de transport en cas de chute de charge."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-107.it.json","api_md":"/api/v1/ch/lev/art-107.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_107","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-107","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_107","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-107","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-107/it/","kennung":"ch/lev/art-107","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 107","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"2a490ac69d0eb70abbb2eb89b3474197cf3ca361307689b00b1112d6e92f4daf","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-107","titel":"Sciovie, impianti a fune per il trasporto di materiali (teleferiche)","typ":"stelle","url":"/ch/lev/art-107/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 L’organo di controllo decide sull’ammissibilità delle vicinanze, dei parallelismi e degli incroci delle linee elettriche aeree con sciovie, teleferiche, gru di sollevamento, palorci e impianti simili.\n2 Esso decide sulle misure di sicurezza. Occorre tener conto, in questi casi, anche dell’escursione verso l’alto della fune di trasporto in seguito a caduta del carico."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-108.de.json","api_md":"/api/v1/ch/lev/art-108.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_108","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-108","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_108","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-108","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-108/de/","kennung":"ch/lev/art-108","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 108","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"c3bacb0110d2726fc1c1f39bfeb6d21cf3ef3030751ac215460674d0e962f6aa","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-108","titel":"Annäherungen und Parallelführungen","typ":"stelle","url":"/ch/lev/art-108/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Der Direktabstand von Leitern und Tragwerken elektrischer Leitungen zu Stützen und Lichtraumprofilen von Luftseilbahnen (Seile und Fahrzeuge und daran angehängten Lasten) muss mindestens 1,5 m plus 0,01 m pro kV Nennspannung betragen.\n2 Der Direktabstand darf nicht unterschritten werden bei der Annäherung:\na. der durch Windeinfluss (bei Staudruck 1 kN/m2) ausgelenkten Teile der Luftseilbahn an die nicht ausgelenkten Leiter oder Luftkabel der Freileitung;\nb. der durch Windeinfluss nach Anhang 6 ausgelenkten Leiter der Freileitung an die nicht ausgelenkten Teile der Luftseilbahn.\n3 Beim Absinken oder Hochschnellen von Leitern der Freileitung bzw. von Seilen oder Drähten der Luftseilbahn darf ein Direktabstand von 0,01 m pro kV Nennspannung, mindestens aber von 1,5 m, nicht unterschritten werden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-108.fr.json","api_md":"/api/v1/ch/lev/art-108.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_108","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-108","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_108","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-108","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-108/fr/","kennung":"ch/lev/art-108","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 108","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"fa67e3ff3031dd10c2b8aad81b87598243861392335ade637b90f6b846c2a41b","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-108","titel":"Rapprochements et parallélismes","typ":"stelle","url":"/ch/lev/art-108/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 La distance directe entre les conducteurs ou les supports de lignes électriques et les pylônes ou les profils d’espace libre des câbles, véhicules et charges suspendues de téléphériques doit être au minimum égale à 1,5 m + 0,01 m par kV de tension nominale.\n2 La distance directe doit être également respectée en cas de rapprochement:\na. de parties du téléphérique déviées sous l’influence du vent (pour une pression dynamique de 1 kN/m2) par rapport aux conducteurs respectivement aux câbles de la ligne aérienne non déviés;\nb. du conducteur de la ligne aérienne dévié sous l’influence du vent (annexe 6) par rapport aux parties du téléphérique non déviées.\n3 La distance directe de 0,01 m par kV de tension nominale, qui ne sera jamais inférieure à 1,5 m, ne peut être réduite ni en cas de chute ni en cas de rebondissement vers le haut des conducteurs de la ligne aérienne ou des câbles du téléphérique."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-108.it.json","api_md":"/api/v1/ch/lev/art-108.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_108","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-108","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_108","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-108","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-108/it/","kennung":"ch/lev/art-108","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 108","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"cb92b380cd00ee49637a9900dcfc19a35ee54043bdcb3c02500f3d20e6914c9f","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-108","titel":"Vicinanze e parallelismi","typ":"stelle","url":"/ch/lev/art-108/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 La distanza diretta tra i conduttori ed i sostegni delle linee elettriche dai sostegni e dalla sagoma limite delle funivie (funi, cabine ed i carichi ad esse appesi), deve ammontare almeno a 1,5 m più 0,01 m per ogni kV di tensione nominale.\n2 La distanza diretta non deve risultare diminuita nel caso di avvicinamenti:\na. delle parti della funivia deviate dalla spinta del vento (per una pressione pari a 1 kN/m2) ai conduttori o ai cavi aerei, non deviati, della linea aerea;\nb. dei conduttori della linea aerea deviati dalla spinta del vento, secondo l’appendice 6, alle parti non deviate della funivia.\n3 La distanza diretta, pari a 0,01 m per ogni kV di tensione nominale, ma non inferiore a 1,5 m, non deve trovarsi diminuita in seguito ad abbassamento o a escursione verso l’alto dei conduttori della linea aerea o delle funi o dei fili della funivia."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-109.de.json","api_md":"/api/v1/ch/lev/art-109.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_109","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-109","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_109","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-109","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-109/de/","kennung":"ch/lev/art-109","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 109","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"205dd944a8883e2a8349ba761255534241a42843e630d35d7230e0863715f2dd","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-109","titel":"Kreuzungen mit Schwachstrom- oder Niederspannungsleitungen","typ":"stelle","url":"/ch/lev/art-109/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Ist eine Kreuzung mit Schwachstrom- oder Niederspannungsleitungen nicht zu vermeiden, so müssen die Leitungen unterirdisch verlegt werden.\n2 Für Kabelendmasten und spannungsführende Teile der Freileitung gelten die Abstände nach Artikel 108."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-109.fr.json","api_md":"/api/v1/ch/lev/art-109.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_109","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-109","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_109","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-109","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-109/fr/","kennung":"ch/lev/art-109","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 109","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"cf00795d0ed86ce4e5e9bbd4c03f4a461276e7ba6c230d51f856f839c182a8fe","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-109","titel":"Croisement avec des lignes à courant faible ou des lignes à basse tension","typ":"stelle","url":"/ch/lev/art-109/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Lorsque le croisement avec des lignes à courant faible ou des lignes à basse tension ne peut être évité, les lignes doivent être enterrées.\n2 Pour les mâts de transition et les parties sous tension de la ligne aérienne, les distances sont celles de l’art. 108."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-109.it.json","api_md":"/api/v1/ch/lev/art-109.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_109","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-109","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_109","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-109","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-109/it/","kennung":"ch/lev/art-109","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 109","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"8d089f99864494cc8f230872ee3006be20ea613df044ccd1e6dbdb1c72af9453","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-109","titel":"Incroci con linee a corrente debole o a bassa tensione","typ":"stelle","url":"/ch/lev/art-109/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Se un incrocio con linee a corrente debole o a bassa tensione non può essere evitato, le linee devono essere fatte passare sottoterra.\n2 Per i sostegni terminali del cavo e le parti sotto tensione della linea aerea valgono le distanze secondo l’articolo 108."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-110.de.json","api_md":"/api/v1/ch/lev/art-110.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_110","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-110","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_110","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-110","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-110/de/","kennung":"ch/lev/art-110","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 110","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"7358abc8087cf00a9310f8297c86cab021bd320d0c1327fcab772974c5bf4350","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-110","titel":"Kreuzungen mit Hochspannungsfreileitungen","typ":"stelle","url":"/ch/lev/art-110/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Ist eine Kreuzung mit einer Hochspannungsfreileitung nicht zu vermeiden, so ist die Freileitung über die Luftseilbahn zu führen.\n2 Kreuzungen von Hochspannungsfreileitungen mit Luftseilbahnen sind möglichst nahe bei den Überführungstragwerken und den Seilbahnstützen anzulegen.\n3 Der Kreuzungswinkel muss mindestens 20 gon betragen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-110.fr.json","api_md":"/api/v1/ch/lev/art-110.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_110","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-110","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_110","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-110","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-110/fr/","kennung":"ch/lev/art-110","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 110","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"c3bb5fd61db997579f0462e4a933ac5a466096d01d5a33370fe73d1d347c0cfd","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-110","titel":"Croisements avec des lignes aériennes à haute tension","typ":"stelle","url":"/ch/lev/art-110/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Lorsque le croisement avec une ligne aérienne à haute tension ne peut être évité, celle-ci doit être placée au-dessus du téléphérique.\n2 Les croisements de lignes aériennes à haute tension avec des téléphériques doivent si possible se situer à proximité des supports de la ligne en survol et des pylônes du téléphérique.\n3 L’angle de croisement doit être d’au moins 20 gr."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-110.it.json","api_md":"/api/v1/ch/lev/art-110.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_110","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-110","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_110","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-110","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-110/it/","kennung":"ch/lev/art-110","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 110","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"3a76ab2d2fd0bbf5c924473ea3ed11aa11bcc911f9999eab709b5ce586135cfb","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-110","titel":"Incroci con linee aeree ad alta tensione","typ":"stelle","url":"/ch/lev/art-110/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Se l’incrocio con una linea aerea ad alta tensione non può essere evitato, la linea aerea deve essere di regola tesa sopra la funivia.\n2 Gli incroci delle linee aeree ad alta tensione devono essere disposti, per quanto possibile, in prossimità dei sostegni della linea sovrapassante e di quelli della funivia.\n3 L’angolo di incrocio non deve essere inferiore a 20 gon."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-111.de.json","api_md":"/api/v1/ch/lev/art-111.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_111","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-111","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_111","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-111","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-111/de/","kennung":"ch/lev/art-111","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 111","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"bf6a2ec8bc4fad3f1f31f8ccc8b22a15b90f57a5c7c8c0a631749d5b6983de0e","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-111","titel":"Abstand übergeführter Hochspannungsfreileitungen","typ":"stelle","url":"/ch/lev/art-111/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Der Direktabstand von Leitern von Hochspannungsfreileitungen zu den Lichtraumprofilen von Luftseilbahnen muss mindestens 1,5 m plus 0,01 m pro kV Nennspannung plus je 0,01 m pro Meter Abstand der Kreuzungsstelle zur nächstliegenden Seilbahnstütze einerseits und zum nächstliegenden Tragwerk der Freileitung andererseits betragen.\n2 Zwischen den Stützen der Luftseilbahn und den Leitern der Freileitung muss der Direktabstand mindestens 1,5 m plus 0,01 m pro kV Nennspannung plus 0,02 m pro Meter Abstand der Kreuzungsstelle zum nächstliegenden Tragwerk der Freileitung betragen. Über begehbaren Teilen solcher Stützen ist dieser Abstand um 1,5 m zu vergrössern.\n3 Die Abstände sind aufgrund folgender Annahmen zu berechnen:\na. einer Leitertemperatur von 0 °C mit Zusatzlast auf der Freileitung und 0,7 fachem Durchhang bei unbelasteten Seilen und Drähten der Luftseilbahn bei 0 °C Seiltemperatur;\nb. einer Leitertemperatur der Freileitung von 40 °C und 0,7 fachem Durchhang bei unbelasteten Seilen und Drähten der Luftseilbahn bei 15 °C Seiltemperatur;\nc. der Windauslenkungen nach Artikel 108 Absatz 2.\n4 Beim Absinken oder Hochschnellen von Leitern der Freileitung bzw. von Seilen oder Drähten der Luftseilbahn darf ein Direktabstand von 0,01 m pro kV Nennspannung, mindestens aber von 1,5 m, nicht unterschritten werden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-111.fr.json","api_md":"/api/v1/ch/lev/art-111.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_111","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-111","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_111","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-111","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-111/fr/","kennung":"ch/lev/art-111","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 111","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"17c6faa04cc38d77bd712fc81f2708aefe8887e4b80e03e30979cb6e5b56aead","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-111","titel":"Distance aux lignes aériennes à haute tension en survol","typ":"stelle","url":"/ch/lev/art-111/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 La distance directe entre des conducteurs de lignes aériennes à haute tension et le profil d’espace libre d’un téléphérique ne doit pas être inférieure à 1,5 m plus 0,01 m par kV de tension nominale plus 0,01 m par mètre de distance entre le point de croisement et le pylône du téléphérique le plus proche d’une part, et le support de la ligne aérienne le plus proche d’autre part.\n2 La distance directe entre les pylônes du téléphérique et les conducteurs de la ligne aérienne, ne doit pas être inférieure à 1,5 m plus 0,01 m par kV de tension nominale plus 0,02 m par mètre de distance entre le point de croisement et le support le plus proche de la ligne aérienne. Cette distance doit être majorée de 1,5 m au-dessus des parties accessibles des pylônes.\n3 Les distances se calculent à partir des hypothèses suivantes:\na. une température du conducteur de 0° C, avec surcharge sur la ligne aérienne et 0,7 fois la flèche considérée pour les câbles et fils de téléphériques non chargés à une température de 0° C;\nb. une température du conducteur de 40° C et 0,7 fois la flèche considérée pour les câbles et fils de téléphériques à 15° C non chargés;\nc. la déviation due au vent selon l’art. 108, al. 2.\n4 La distance directe de 0,01 m par kV de tension nominale, qui ne sera jamais inférieure à 1,5 m, ne peut être réduite ni en cas de chute ni en cas de rebondissement vers le haut des conducteurs de la ligne aérienne, des câbles ou des fils du téléphérique."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-111.it.json","api_md":"/api/v1/ch/lev/art-111.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_111","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-111","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_111","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-111","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-111/it/","kennung":"ch/lev/art-111","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 111","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"9550919c3838e2151077208059da982c094526c375fc918be2c6c799479cfe7f","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-111","titel":"Distanza delle linee aeree ad alta tensione sovrapassanti","typ":"stelle","url":"/ch/lev/art-111/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 La distanza diretta tra i conduttori delle linee aeree ad alta tensione e le sagome di spazio libero delle funivie non deve, di regola, essere inferiore a 1,5 m più 0,01 m per ogni kV di tensione nominale, più 0,01 m per ogni metro di distanza tra il punto di incrocio ed il sostegno più vicino della funivia da un lato, e tra il punto di incrocio ed il più vicino sostegno della linea aerea d’altro lato.\n2 La distanza diretta tra i sostegni della funivia ed i conduttori della linea aerea non deve essere inferiore a 1,5 m più 0,01 m per ogni kV di tensione nominale, più 0,02 m per ogni metro di distanza tra il punto di incrocio ed il sostegno più vicino della linea aerea. Detta distanza deve essere aumentata di 1,5 m al disopra delle parti accessibili dei sostegni della funivia.\n3 Le distanze vanno calcolate in base alle seguenti ipotesi:\na. una temperatura dei conduttori di 0° C con sovraccarico sulla linea aerea, ed una freccia pari a 0,7 volte la freccia assunta dalle funi e dai fili della funivia in assenza di carico ed alla temperatura di 0° C;\nb. una temperatura dei conduttori della linea aerea di +40° C ed una freccia pari a 0,7 volte la freccia assunta dalle funi e di fili della funivia, in assenza di carico e alla temperatura di +15° C;\nc. gli spostamenti provocati dalla spinta del vento, secondo l’articolo 108 capoverso 2.\n4 La distanza diretta, pari a 0,01 m per ogni kV di tensione nominale, ma non inferiore a 1,5 m, non deve trovarsi diminuita in seguito ad abbassamento dei conduttori della linea aerea o a escursione rapida verso l’alto di funi o fili della funivia."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-112.de.json","api_md":"/api/v1/ch/lev/art-112.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_112","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-112","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_112","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-112","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-112/de/","kennung":"ch/lev/art-112","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 112","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"7214993423da638e80fc9495b95a31cec668e34795fa436801791856124d91cb","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-112","titel":"Schutzkonstruktion über Luftseilbahnen","typ":"stelle","url":"/ch/lev/art-112/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Können die Abstände nach Artikel 111 nicht eingehalten werden, so entscheidet die Kontrollstelle:\na. über die Zulässigkeit der Überführung;\nb. über die zu treffenden Schutzmassnahmen.\n2 Schreibt die Kontrollstelle eine Schutzkonstruktion über der Luftseilbahn vor, so muss die Konstruktion die äussersten Leiter der Freileitungen seitlich so überragen, dass sie absinkende Leiter oder hochschnellende Drähte und Seile aufhalten kann.\n3 Zwischen der Schutzkonstruktion und den Leitern der Freileitung muss der Direktabstand bei grösstem Leiterdurchhang mindestens 1,5 m plus 0,01 m pro kV Nennspannung plus 0,02 m pro Meter Abstand der Kreuzungsstelle zum nächstliegenden Tragwerk der Freileitung betragen.\n4 Kann die Schutzkonstruktion für Instandhaltungs- und Prüfarbeiten bei der Luftseilbahn bestiegen werden, so ist der Abstand nach Absatz 3 um 1,5 m zu vergrössern."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-112.fr.json","api_md":"/api/v1/ch/lev/art-112.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_112","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-112","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_112","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-112","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-112/fr/","kennung":"ch/lev/art-112","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 112","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"86d1fec21be519be93ecff6e82bf250e593cbdd8b16fcbb2b87ba36ec1301c6c","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-112","titel":"Construction protectrice au-dessus des téléphériques","typ":"stelle","url":"/ch/lev/art-112/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Lorsque les distances prescrites à l’art. 111 ne peuvent être respectées, l’organe de contrôle décide:\na. si le survol est admissible;\nb. des mesures de protection adéquates.\n2 Lorsque l’organe de contrôle prescrit une construction protectrice au-dessus du téléphérique, celle-ci doit dépasser latéralement les conducteurs extérieurs de la ligne aérienne de façon à retenir les conducteurs affaissés ou les fils et les câbles rebondissant vers le haut.\n3 La distance directe entre la construction protectrice et les conducteurs de la ligne aérienne mesurée avec la flèche maximale de ces derniers, ne doit pas être inférieure à 1,5 m plus 0,01 m par kV de tension nominale plus 0,02 m par mètre de distance entre le point de croisement et le support le plus proche de la ligne aérienne.\n4 La distance mentionnée à l’al. 3 doit être majorée de 1,5 m si la construction protectrice est prévue pour être escaladée lors des travaux d’entretien ou d’essai du téléphérique."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-112.it.json","api_md":"/api/v1/ch/lev/art-112.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_112","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-112","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_112","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-112","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-112/it/","kennung":"ch/lev/art-112","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 112","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"956ebb13c401683c9bda640a80b8286e3135b1e1f5262d5df0f11f6e09e962d6","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-112","titel":"Costruzioni protettive sopra le funivie","typ":"stelle","url":"/ch/lev/art-112/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Se le esigenze di cui all’articolo 111 non possono essere soddisfatte, l’organo di controllo decide:\na. in merito all’ammissibilità del soprapassaggio;\nb. in merito alle misure protettive da adottare.\n2 Se l’organo di controllo prescrive una costruzione protettiva al disopra della funivia, questa deve estendersi lateralmente oltre i conduttori più esterni delle linee aeree in modo da poter trattenere sia i conduttori caduti, sia le funi o i fili oscillanti verticalmente.\n3 Tra la costruzione protettiva ed i conduttori della linea aerea la distanza diretta, in presenza della freccia massima, non deve mai essere inferiore a 1,5 m più 0,01 m per ogni kV di tensione nominale, più 0,02 m per ogni metro di distanza tra il punto d’incrocio ed il sostegno più vicino della linea aerea.\n4 Se la costruzione protettiva può essere scalata per lavori di manutenzione e di controllo da eseguire sulla funivia, la distanza secondo il capoverso 3 deve essere maggiorata di 1,5 m."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-113.de.json","api_md":"/api/v1/ch/lev/art-113.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_113","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-113","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_113","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-113","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-113/de/","kennung":"ch/lev/art-113","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 113","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"f6ca4765bc38f77cdc02707a5d2050a417c33a977393fe78a29b193f6afe851a","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-113","titel":"Untergeführte Hochspannungsfreileitungen","typ":"stelle","url":"/ch/lev/art-113/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Muss eine Hochspannungsfreileitung ausnahmsweise unter einer Luftseilbahn hindurchgeführt werden, so ist eine Schutzkonstruktion zu erstellen, damit herabhängende oder ‑fallende Seile der Luftseilbahn sich den Leitern nicht unzulässig annähern können.\n2 Auf die Erstellung der Schutzkonstruktion kann verzichtet werden, wenn:\na. der Abstand zwischen den Seilen der Luftseilbahn und den Leitern der Hochspannungsfreileitung so gross ist, dass eine unzulässige Annäherung auch bei ausserordentlichen Betriebszuständen der Luftseilbahn ausgeschlossen ist; und\nb. eine Bergung von Reisenden nicht unzulässig behindert wird.\n3 Die Abstände der Schutzkonstruktion zu den Leitern bestimmen sich nach Anhang 6.\n4 Die Abmessungen der Schutzkonstruktion richten sich nach den örtlichen Gegebenheiten, namentlich nach der seitlichen Windauslenkung der Luftseilbahn.\n5 Können bei ausserordentlichen Betriebszuständen der Luftseilbahn (z. B. brüske Bremsung) deren Seile ausnahmsweise die Schutzkonstruktion berühren oder auf dieser aufliegen, so muss die Schutzkonstruktion entsprechend dimensioniert und so ausgeführt sein, dass die Seile nicht beschädigt werden.\n6 Können Reisende in blockierten Seilbahnfahrzeugen nicht mit einer Bergungsbahn geborgen werden, so muss die Schutzkonstruktion so ausgeführt sein, dass das Abseilen der Reisenden möglich ist."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-113.fr.json","api_md":"/api/v1/ch/lev/art-113.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_113","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-113","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_113","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-113","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-113/fr/","kennung":"ch/lev/art-113","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 113","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"364ca277444f22fdfc57aa35fd40c6eda1b989a6f48909d4086dfae734500613","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-113","titel":"Passages de lignes aériennes à haute tension au-dessous des téléphériques","typ":"stelle","url":"/ch/lev/art-113/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Lorsqu’une ligne aérienne à haute tension doit exceptionnellement passer au-dessous d’un téléphérique, on érigera une construction protectrice afin d’éviter que des câbles du téléphérique détendus ou tombés ne se rapprochent de façon inadmissible des conducteurs de courant.\n2 On pourra se passer d’une construction protectrice:\na. lorsque la distance entre les câbles du téléphérique et les conducteurs de la ligne aérienne à haute tension est telle qu’un rapprochement inadmissible ne peut avoir lieu, même en cas de situation extraordinaire; et\nb. que le sauvetage des voyageurs ne s’en trouve pas entravé de façon inadmis-sible.\n3 Les distances entre la construction protectrice et les conducteurs de courant sont données à l’annexe 6.\n4 Les dimensions de la construction protectrice sont imposées par les conditions locales, notamment par la déviation du téléphérique due au vent.\n5 Si en cas de situation extraordinaire (par exemple de freinage brusque) les câbles du téléphérique sont susceptibles d’entrer en contact avec la construction protectrice ou de se poser dessus, ladite construction protectrice doit être dimensionnée en conséquence et conçue pour ne pas endommager ces câbles.\n6 Si les voyageurs d’une cabine de téléphérique bloquée ne peuvent être évacués par un téléphérique de secours, la construction protectrice doit être aménagée de façon a permettre l’évacuation des voyageurs au moyen d’une corde de rappel."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-113.it.json","api_md":"/api/v1/ch/lev/art-113.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_113","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-113","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_113","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_3","num":"3. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Luftseilbahnen und Skiliften"}],"id":"ch/lev/art-113","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-113/it/","kennung":"ch/lev/art-113","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 113","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"8649ce3edf31f3ccac51389db353e40e076ec78b43f7aa5540ae1b23f86494d2","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-113","titel":"Linee aeree ad alta tensione sottopassanti","typ":"stelle","url":"/ch/lev/art-113/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Se una linea aerea ad alta tensione deve in via eccezionale passare al disotto di una funivia, occorre erigere una costruzione protettiva così che le funi pendenti o cadute della funivia non possano avvicinarsi in modo inammissibile ai conduttori della linea.\n2 Si può rinunciare alla costruzione protettiva quando:\na. la distanza tra le funi della funivia ed i conduttori della linea ad alta tensione sia tale da poter escludere, anche in condizioni straordinarie d’esercizio dell’impianto di trasporto, che si verifichi un avvicinamento inammissibile;\nb. il recupero dei viaggiatori non venga ostacolato in modo inammissibile;\n3 Le distanze tra le costruzioni protettive ed i conduttori della linea si determinano in base all’appendice 6.\n4 Le dimensioni delle costruzioni protettive sono determinate in funzione delle condizioni locali, tenendo conto in particolare dello spostamento trasversale della funivia sotto la spinta del vento.\n5 Se, in seguito a condizioni straordinarie d’esercizio della funivia (ad es. frenatura brusca), le funi della stessa possono eccezionalmente venire in contatto con la costruzione protettiva o poggiare sulla stessa, dette costruzioni protettive vanno dimensionate in conseguenza e costruite in modo che le funi non possano subire danni.\n6 Quando i viaggiatori bloccati nelle cabine della funivia non possono essere portati al sicuro con un impianto di recupero, la costruzione protettiva va concepita in modo che sia possibile far scendere gli stessi mediante corde."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-114.de.json","api_md":"/api/v1/ch/lev/art-114.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_114","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-114","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_114","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-114","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-114/de/","kennung":"ch/lev/art-114","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 114","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"bb4d214a7108c5e6e16970a9a7b8ef5d1a9a94b4b30494cebfe35129614a3b46","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-114","titel":"Rücksicht auf den Weiterausbau der Nationalstrassen","typ":"stelle","url":"/ch/lev/art-114/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Elektrische Leitungen sind so zu planen und zu erstellen, dass sie einen geplanten Weiterausbau der Nationalstrassen nicht behindern."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-114.fr.json","api_md":"/api/v1/ch/lev/art-114.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_114","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-114","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_114","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-114","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-114/fr/","kennung":"ch/lev/art-114","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 114","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"30cced944ad2e818f0e3f89702c2be2cf7a7e0471294de70aecd3b07edb035b7","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-114","titel":"Prise en considération des projets d’extension des routes nationales","typ":"stelle","url":"/ch/lev/art-114/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les lignes électriques doivent être planifiées et établies de façon à ne pas entraver les projets d’extension des routes nationales."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-114.it.json","api_md":"/api/v1/ch/lev/art-114.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_114","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-114","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_114","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-114","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-114/it/","kennung":"ch/lev/art-114","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 114","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"9643a03261347fdc65ad8f0c92cf788cd1f688a328550416e25d4b48cbd6e1a6","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-114","titel":"Considerazione di futuri ampliamenti delle strade nazionali","typ":"stelle","url":"/ch/lev/art-114/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Le linee elettriche devono essere progettate e costruite in modo da non ostacolare gli ampliamenti già pianificati delle strade nazionali."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-115.de.json","api_md":"/api/v1/ch/lev/art-115.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_115","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-115","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_115","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-115","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-115/de/","kennung":"ch/lev/art-115","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 115","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"3513c3f2379197713c3a8e20bdb323622fa0242feddecef7d089b30bd53f0d41","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-115","titel":"Anordnung von Tragwerken","typ":"stelle","url":"/ch/lev/art-115/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Freileitungen sind so zu planen und zu erstellen, dass für den Verkehr auf den Nationalstrassen keine Sichtbehinderung entstehen (Signalisation, Wegweiser usw.).\n2 Tragwerke sind speziell zu schützen, wenn die Gefahr ihrer Beschädigung durch Fahrzeuge besteht. Der Horizontalabstand von Fundamentsockeln und Schaftteilen zur äusseren Standspurgrenze muss mindestens 5 m betragen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-115.fr.json","api_md":"/api/v1/ch/lev/art-115.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_115","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-115","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_115","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-115","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-115/fr/","kennung":"ch/lev/art-115","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 115","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"e653e7c5ebd69ab1cc205ffa66f2597a05128ca32d68bd4825d8b48724fa012f","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-115","titel":"Disposition des supports","typ":"stelle","url":"/ch/lev/art-115/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les lignes aériennes doivent être planifiées et établies de façon à ne pas entraver la visibilité du trafic sur les routes nationales (signalisation, panneaux indicateurs, etc.).\n2 Les supports doivent être spécialement protégés s’ils risquent d’être endommagés par la collision d’un véhicule. La distance horizontale entre les socles de fondations ou les parties du support et la limite extérieure de la piste de stationnement doit être au minimum de 5 m."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-115.it.json","api_md":"/api/v1/ch/lev/art-115.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_115","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-115","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_115","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-115","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-115/it/","kennung":"ch/lev/art-115","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 115","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"f9c52e617ea1889952e3481eada217a2ccb4c5c28430c696e9b8928252dc9bca","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-115","titel":"Disposizione dei sostegni","typ":"stelle","url":"/ch/lev/art-115/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le linee aeree devono essere progettate e costruite in modo da non ostacolare la visibilità sulla strada nazionale (segnaletica, indicatori stradali, ecc.).\n2 I sostegni devono essere protetti in modo particolare quando esiste pericolo di danneggiamento da parte degli autoveicoli. La distanza orizzontale degli zoccoli di fondazione e degli steli dalla linea di corsia più esterna non deve scendere al disotto di 5 m."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-116.de.json","api_md":"/api/v1/ch/lev/art-116.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_116","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-116","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_116","fussnoten":[{"marker":"38","nummer":38,"text":"Fassung gemäss Anhang der V vom 19. Juni 2015, in Kraft seit 1. Jan. 2016 (AS 2015 2263)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-116","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-116/de/","kennung":"ch/lev/art-116","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 116","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"1421d00266d56cfef97953f9bb78c8dae89518208ad3dfdbfe70341453559d26","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-116","titel":"Zusätzliche Bewilligung","typ":"stelle","url":"/ch/lev/art-116/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Leitungsteile von Freileitungen innerhalb der Baulinienabstände von Nationalstrassen müssen auch vom Bundesamt für Strassen bewilligt werden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-116.fr.json","api_md":"/api/v1/ch/lev/art-116.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_116","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-116","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_116","fussnoten":[{"marker":"37","nummer":37,"text":"Nouvelle teneur selon l’annexe de l’O du 19 juin 2015, en vigueur depuis le 1er janv. 2016 (RO 2015 2263)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-116","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-116/fr/","kennung":"ch/lev/art-116","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 116","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"fca6ff86970d59fc07a1577cb59eb501b533a0cb7a5b84d37d700c3b156d8391","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-116","titel":"Autorisation complémentaire","typ":"stelle","url":"/ch/lev/art-116/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les tronçons de lignes aériennes situés à l’intérieur des alignements de routes nationales doivent avoir été autorisés par l’Office fédéral des routes."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-116.it.json","api_md":"/api/v1/ch/lev/art-116.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_116","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-116","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_116","fussnoten":[{"marker":"39","nummer":39,"text":"Nuovo testo giusta l’all. dell’O del 19 giu. 2015, in vigore dal 1° gen. 2016 (RU 2015 2263)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-116","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-116/it/","kennung":"ch/lev/art-116","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 116","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"e9b2c0ef26446d89418e70ff943bfdf6faa086273b39222d8c7bd5746b26f71b","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-116","titel":"Autorizzazione supplementare","typ":"stelle","url":"/ch/lev/art-116/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Le parti della linea aerea all’interno degli allineamenti delle strade nazionali devono essere approvate anche dall’Ufficio federale delle strade."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-117.de.json","api_md":"/api/v1/ch/lev/art-117.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_117","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-117","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_117","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-117","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-117/de/","kennung":"ch/lev/art-117","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 117","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"4cd232de9e1bdd5db50a8b75f060e0d4dad7a715ad4a8fc47fc93e48d6b3021e","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-117","titel":"Erdungen","typ":"stelle","url":"/ch/lev/art-117/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Metallene Zäune, durchgehende Leitplanken oder Leitungsanlagen von Nationalstrassen sind im Einflussbereich von Tragwerkserdungen so zu verlegen, elektrisch aufzutrennen oder zu isolieren, dass weder gefährliche Berührungsspannungen noch Spannungsverschleppungen auftreten können."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-117.fr.json","api_md":"/api/v1/ch/lev/art-117.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_117","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-117","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_117","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-117","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-117/fr/","kennung":"ch/lev/art-117","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 117","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"395cf1dadab9fbc420ff97e0444b79c4eaf87df144312ce1467e488181ad5f30","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-117","titel":"Mises à la terre","typ":"stelle","url":"/ch/lev/art-117/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les clôtures métalliques, les glissières de sécurité continues ou les installations de lignes de la route nationale situées dans la zone d’influence des terres de supports requièrent un mode de pose approprié, une séparation électrique ou une isolation afin qu’aucune tension de contact dangereuse ni aucune migration de potentiel ne puissent y apparaître."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-117.it.json","api_md":"/api/v1/ch/lev/art-117.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_117","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-117","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_117","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-117","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-117/it/","kennung":"ch/lev/art-117","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 117","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"7ac791b091ccd4cb286b05d0018a428293ed8d06e35b7c3fe2e167d96716bdd7","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-117","titel":"Messe a terra","typ":"stelle","url":"/ch/lev/art-117/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"All’interno delle zone di rispetto delle terre dei sostegni, le griglie metalliche, le barriere continue o gli impianti di linee delle strade nazionali devono essere posati, separati elettricamente o isolati in modo che non possano verificarsi tensioni di contatto o trasferimenti di potenziale pericolosi."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-118.de.json","api_md":"/api/v1/ch/lev/art-118.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_118","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-118","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_118","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-118","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-118/de/","kennung":"ch/lev/art-118","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 118","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"f6871809ec5cfb61d7c39d68a3981674553b39fdf3c5585463155e798edc553d","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-118","titel":"Annäherungen und Parallelführungen","typ":"stelle","url":"/ch/lev/art-118/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Bei Annäherungen und Parallelführungen von Freileitungen mit Nationalstrassen sind ausreichende Horizontalabstände vorzusehen oder Schutzmassnahmen gegen unzulässige induzierte Längsspannungen an Anlagen der Nationalstrasse zu treffen.\n2 Der Horizontalabstand zwischen der äusseren Standspurgrenze und dem nächsten Leiter oder Luftkabel muss mindestens 1 m betragen.\n3 Beschränkt sich die Annäherung auf eine Spannweite, so gilt sie als Kreuzung."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-118.fr.json","api_md":"/api/v1/ch/lev/art-118.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_118","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-118","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_118","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-118","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-118/fr/","kennung":"ch/lev/art-118","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 118","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"030bcc17a9874082e1a937827b38bf7e6abb5317a3b52db62bca7abb8f76e5ee","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-118","titel":"Rapprochements et parallélismes","typ":"stelle","url":"/ch/lev/art-118/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 En cas de rapprochement ou de parallélisme de lignes aériennes avec une route nationale, on prévoira des distances horizontales suffisantes ou prendra des mesures de protection contre les composantes longitudinales inadmissibles de tensions induites sur les installations de la route nationale.\n2 La distance horizontale entre la limite extérieure de la piste de stationnement et le conducteur ou le câble aérien le plus proche doit être au minimum de 1 m.\n3 Lorsque le rapprochement est limité à une portée, il doit être considéré comme un croisement."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-118.it.json","api_md":"/api/v1/ch/lev/art-118.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_118","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-118","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_118","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-118","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-118/it/","kennung":"ch/lev/art-118","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 118","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"bc458f8915659c2cc6175d0cbfe3a76c624e4fadb3efb82b83fa67ff9f4d37ba","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-118","titel":"Vicinanze e parallelismi","typ":"stelle","url":"/ch/lev/art-118/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Nei casi di vicinanze e di parallelismi delle linee aeree con le strade nazionali, si devono prevedere distanze orizzontali sufficienti o disporre misure protettive contro l’induzione di potenziali longitudinali lungo gli impianti delle strade nazionali.\n2 La distanza orizzontale tra la linea di corsia più esterna ed il conduttore o il cavo aereo più vicino non deve scendere al disotto di 1 m.\n3 Se la vicinanza abbraccia una sola campata, essa è considerata un incrocio."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-119.de.json","api_md":"/api/v1/ch/lev/art-119.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_119","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-119","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_119","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-119","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-119/de/","kennung":"ch/lev/art-119","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 119","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"1a415e2bec25f60aa046ad7f030cdda7a252b5985505e8654410c5afe7d5027b","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-119","titel":"Kreuzungen","typ":"stelle","url":"/ch/lev/art-119/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Bei Kreuzungen mit Nationalstrassen müssen Schwachstrom- oder Niederspannungsfreileitungen unterführt werden.\n2 Hochspannungsfreileitungen sind so anzulegen, dass wenig Kreuzungen mit Nationalstrassen und den dazugehörenden Rastplätzen entstehen.\n3 Die Bodenabstände der Erdleiter, Leiter und Luftkabel bestimmen sich nach Anhang 3."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-119.fr.json","api_md":"/api/v1/ch/lev/art-119.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_119","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-119","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_119","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-119","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-119/fr/","kennung":"ch/lev/art-119","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 119","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"b48024bf987b47ef1cf5c952247be02979b7f83332f0ccd46f2d6e995f49b2cc","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-119","titel":"Croisements","typ":"stelle","url":"/ch/lev/art-119/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les lignes à courant faible ou à basse tension doivent être souterraines à l’endroit où elles croisent les routes nationales.\n2 Les lignes aériennes à haute tension doivent être disposées de façon à limiter les croisements avec les routes nationales et les aires de repos attenantes.\n3 Les distances au sol des conducteurs de terre, des conducteurs et des câbles aériens figurent à l’annexe 3."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-119.it.json","api_md":"/api/v1/ch/lev/art-119.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_119","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-119","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_119","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-119","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-119/it/","kennung":"ch/lev/art-119","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 119","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"f72ff8be27315ab17c115cbac28a6ca4a6485aaa20828877bac9bead48d2a425","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-119","titel":"Incroci","typ":"stelle","url":"/ch/lev/art-119/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Ai punti di incrocio con le strade nazionali, le linee aeree a corrente debole o a bassa tensione devono essere fatte passare sottoterra.\n2 Le linee aeree ad alta tensione devono essere installate in modo da ridurre al minimo il numero degli incroci con le strade nazionali e con le relative aree di ristoro.\n3 Le distanze dal suolo delle linee di terra, dei conduttori e dei cavi aerei sono regolate nell’appendice 3."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-120.de.json","api_md":"/api/v1/ch/lev/art-120.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_120","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-120","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_120","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-120","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-120/de/","kennung":"ch/lev/art-120","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 120","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"0215a1181cd4e0e34a46d7bdd87916911a938feb2400d4cfa31b9055dcebee01","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-120","titel":"Freileitungsunterführungen bei Brücken","typ":"stelle","url":"/ch/lev/art-120/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Wird eine Hochspannungsfreileitung unter einer Strassenbrücke hindurchgeführt, so müssen Leiter, Erdleiter und Luftkabel zu Konstruktionsteilen und Betriebseinrichtungen der Brücke folgende Mindestabstände aufweisen:\na. einen Direktabstand von mindestens 2,5 m plus 0,01 m pro kV Nennspannung bei 0 °C Leitertemperatur ohne Zusatzlast;\nb. einen Horizontalabstand von mindestens 1,5 m plus 0,01 m pro kV Nennspannung für Leiter bei Windauslenkung.\n2 Dient die Brücke auch dem allgemeinen Fussgängerverkehr oder beträgt der Horizontalabstand zwischen der Brücke und einem Unterführungstragwerk weniger als 25 m, so ist an der Brücke ein 1,8 m hohes Schutzgitter mit Warnzeichen anzubringen, die auf die Gefahren beim Berühren von spannungsführenden Teilen hinweisen. Dieses Gitter muss beidseitig mindestens 2 m über die Leitungsbreite hinausreichen.\n3 Instandhaltungsarbeiten, Schneeräumungen und Reparaturen an und auf der Brücke dürfen durch die Hochspannungsleitung nicht beeinträchtigt werden. Sie sind schriftlich zu vereinbaren."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-120.fr.json","api_md":"/api/v1/ch/lev/art-120.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_120","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-120","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_120","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-120","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-120/fr/","kennung":"ch/lev/art-120","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 120","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"17473ddb7a6557717d59db56c874d22a68011bf8ed5b8789ed1744f0bb776766","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-120","titel":"Passages de lignes aériennes sous les ponts","typ":"stelle","url":"/ch/lev/art-120/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Lorsqu’une ligne aérienne à haute tension passe sous un pont destiné à la circulation routière, on respectera les distances suivantes entre les conducteurs, les conducteurs de terre, les câbles aériens et les éléments de construction ou les installations d’exploitation du pont:\na. une distance directe minimale de 2,5 m + 0,01 m par kV de tension nominale pour une température du conducteur de 0° C sans surcharge;\nb. une distance horizontale minimale de 1,5 m + 0,01 m par kV de tension nominale en cas de déviations du conducteur dues au vent.\n2 Si le pont est ouvert aux piétons ou si la distance horizontale entre le pont et le support de la ligne passant en dessous inférieure à 25 m, on posera sur le pont un treillis de protection d’une hauteur de 1,8 m, muni de signaux avertissant du danger encouru à toucher les éléments sous tension. Ce treillis devra dépasser de 2 m au moins de chaque côté de l’emprise de la ligne.\n3 La présence de la ligne à haute tension ne doit être préjudiciable ni au déblaiement de la neige ni aux travaux d’entretien ou de répartition du pont. Ces travaux doivent être exécutés sur la base de conventions écrites."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-120.it.json","api_md":"/api/v1/ch/lev/art-120.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_120","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-120","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_120","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-120","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-120/it/","kennung":"ch/lev/art-120","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 120","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"0cf19bcdbf9e759bd59313d127bdf2861a1764c8b11be2e35633fc9f81213106","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-120","titel":"Passaggi di linee aeree sotto i ponti","typ":"stelle","url":"/ch/lev/art-120/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Nel caso che una linea aerea ad alta tensione debba sottopassare un ponte stradale, i conduttori, i conduttori di terra e i cavi aerei devono avere le seguenti distanze minime dalle parti costruttive e dai dispositivi d’esercizio del ponte:\na. una distanza diretta almeno pari a 2,5 m + 0,01 m per ogni kV di tensione nominale, per una temperatura dei conduttori di 0° C ed in assenza di sovraccarico;\nb. una distanza orizzontale almeno pari a 1,5 m + 0,01 m per ogni kV di tensione nominale, per conduttori deviati dalla spinta del vento.\n2 Se il ponte è aperto al traffico pedonale oppure la distanza orizzontale tra il ponte ed un sostegno della linea sottopassante è inferiore a 25 m, è necessario apporre una rete di protezione alta 1,8 m con cartelli d’avvertimento che accennano al pericolo di toccare parti sotto tensione. Detta rete deve estendersi per almeno 2 m da ambedue i lati della linea sottopassante, oltre la larghezza della stessa.\n3 I lavori di manutenzione, lo sgombero della neve e le riparazioni al e sul ponte non devono essere ostacolati dalla presenza della linea ad alta tensione. Essi devono essere convenuti per iscritto."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-121.de.json","api_md":"/api/v1/ch/lev/art-121.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_121","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-121","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_121","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-121","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-121/de/","kennung":"ch/lev/art-121","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 121","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"93c2181dc325e5c14cf9278f2744e09f84546c0559b445806b5634b0ee65e461","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-121","titel":"Kabelleitungen","typ":"stelle","url":"/ch/lev/art-121/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Kabelleitungen dürfen bei Annäherungen, Parallelführungen und Kreuzungen mit Verkehrswegen (Strassen, Tunnels, Brücken usw.) nicht durch Schwingungen und Erschütterungen beeinträchtigt werden. Sie müssen bei gelenkigen Konstruktionselementen (Brücken) eine ausreichende Beweglichkeit aufweisen.\n2 Kabelleitungen für Anlagen mit wichtigen Schutz- und Sicherheitsfunktionen sind so zu erstellen, dass sie bei Pannen oder Verkehrsunfällen weder mechanisch noch durch Öl, Benzin oder andere brennende oder ätzende Flüssigkeiten beschädigt werden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-121.fr.json","api_md":"/api/v1/ch/lev/art-121.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_121","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-121","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_121","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-121","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-121/fr/","kennung":"ch/lev/art-121","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 121","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"20bc368f8a78108205bda944c368b642517b4ea468881660c98c87ce850be004","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-121","titel":"Lignes en câbles","typ":"stelle","url":"/ch/lev/art-121/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 En cas de rapprochement, de parallélisme ou de croisement avec des voies de circulation (routes, tunnels, ponts, etc.), les lignes en câbles ne doivent pas être endommagées par les oscillations, les vibrations et les secousses. Elles doivent disposer d’une liberté de mouvement suffisante au sein des éléments de construction articulés (ponts).\n2 En cas de panne ou d’accident de la circulation, les lignes en câbles pour des installations revêtant d’importantes fonctions de protection et de sécurité doivent être établies de façon qu’elles ne puissent être détériorées ni mécaniquement ni par l’huile, par l’essence ou par d’autres liquides inflammables ou corrosifs."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-121.it.json","api_md":"/api/v1/ch/lev/art-121.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_121","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-121","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_121","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-121","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-121/it/","kennung":"ch/lev/art-121","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 121","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"afba2993ab5b1fd3678fe89667959359d38085a13709e10c41984ec45ece9ed4","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-121","titel":"Linee in cavo","typ":"stelle","url":"/ch/lev/art-121/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Nelle vicinanze, nei parallelismi e negli incroci con vie di comunicazione (strade, ponti, gallerie, ecc.), le linee in cavo non devono essere danneggiate dalle vibrazioni e dalle scosse. Esse devono possedere una sufficiente flessibilità in presenza di elementi costruttivi incernierati (ponti).\n2 Le linee in cavo per impianti con importanti funzioni di protezione e di sicurezza devono essere costruite in modo da non poter subire danni meccanici o provocati da olio, benzina o da altri liquidi in fiamme o corrosivi in conseguenza di guasti o incidenti del traffico."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-122.de.json","api_md":"/api/v1/ch/lev/art-122.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_122","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-122","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_122","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-122","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-122/de/","kennung":"ch/lev/art-122","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 122","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"7dc2f505c57996f810c90a2b16a903b1f2831f6b2c46f757276e7cedc83931c7","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-122","titel":"Kabelkanäle und ‑durchführungen","typ":"stelle","url":"/ch/lev/art-122/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Kabelleitungen in Kabelkanälen müssen so geplant und erstellt werden, dass bei Kabelbränden der Verkehr nicht gefährdet wird.\n2 Kabelkanäle in Tunnels dürfen keine Werkstoffe enthalten, die grosse Verqualmungen verursachen.\n3 Kabeldurchführungen in Tunnels, die zwischen dem Verkehrsraum und elektrischen Anlagen liegen und Brände verschleppen können, sind feuerhemmend abzudichten."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-122.fr.json","api_md":"/api/v1/ch/lev/art-122.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_122","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-122","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_122","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-122","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-122/fr/","kennung":"ch/lev/art-122","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 122","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"14619f8128f1bd40aa10d680562e3b22e21eddc877b4b472b447184486454540","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-122","titel":"Caniveaux et traversées de câbles","typ":"stelle","url":"/ch/lev/art-122/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les lignes en câbles dans les caniveaux doivent être planifiées et établies de façon qu’elles ne mettent pas en danger la circulation en cas d’incendie des câbles.\n2 Les caniveaux de câbles posés dans les tunnels ne doivent pas être constitués de matériaux susceptibles de dégager une épaisse fumée en cas d’incendie.\n3 Dans un tunnel, les traversées de câbles sises entre les voies de circulation et les installations électriques doivent être étanchées de façon à empêcher la propagation du feu."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-122.it.json","api_md":"/api/v1/ch/lev/art-122.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_122","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-122","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_122","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_4","num":"4. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Nationalstrassen und anderen Verkehrswegen"}],"id":"ch/lev/art-122","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-122/it/","kennung":"ch/lev/art-122","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 122","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"f02f3e9da303da6c194dc4083405b7d620260642ca8aa62a399df70314d08c33","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-122","titel":"Canali e passaggi per cavi","typ":"stelle","url":"/ch/lev/art-122/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le linee in cavo all’interno dei canali devono essere progettate e disposte in modo da non mettere in pericolo il traffico in caso di incendio dei cavi.\n2 I canali per cavi posati all’interno delle gallerie non devono contenere materiali che possono produrre grandi quantità di fumo.\n3 I passaggi di cavi nelle gallerie, posati tra la via di traffico e gli impianti elettrici e che possono propagare incendi, devono essere schermati con materiale ignifugo."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-123.de.json","api_md":"/api/v1/ch/lev/art-123.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_123","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-123","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_123","fussnoten":[{"marker":"39","nummer":39,"text":"Fassung gemäss Anhang 2 Ziff. 2 der Rohrleitungssicherheitsverordnung vom 4. Juni 2021, in Kraft seit 1. Juli 2021 (AS 2021 348)."},{"marker":"40","nummer":40,"text":"SR 746.1"},{"marker":"41","nummer":41,"text":"SR 734.2"},{"marker":"42","nummer":42,"text":"SR 746.12"}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_5","num":"5. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Rohrleitungsanlagen"}],"id":"ch/lev/art-123","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-123/de/","kennung":"ch/lev/art-123","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 123","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"e4fb84d2dacd4c388e41a2838c350eb5040350f3d2de96df5904bea2decfa6dd","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-123","titel":"Unterirdische Rohrleitungen und Nebenanlagen","typ":"stelle","url":"/ch/lev/art-123/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Für die Erstellung von elektrischen Leitungen in einem Abstand von weniger als 30 m zu Rohrleitungen, die dem Rohrleitungsgesetz vom 4. Oktober 1963 unterstellt sind, ist abzuklären:\na. ob die zulässigen Spannungen nach Anhang 4 der Starkstromverordnung vom 30. März 1994 an der Rohrleitungsanlage nicht überschritten werden;\nb. welche Schutzmassnahmen zu treffen sind.\n2 Die Abklärung ist nur in Bezug auf die Fernmelde- und Fernsteuerungsanlagen vorzunehmen, wenn die Rohrleitung:\na. ohne elektrische Isolation direkt im Erdreich verlegt ist;\nb. auf der Parallelstrecke geerdet ist; oder\nc. aus nicht leitendem Material besteht.\n3 Sie erübrigt sich vollständig, wenn der Sternpunkt des Hochspannungsnetzes von der Erde isoliert betrieben wird oder mit Erdschlusslöschung versehen ist.\n4 Der Gefahr der Gleichstrom- und der Wechselstromkorrosion ist Rechnung zu tragen.\n5 Im Schutzbereich einer Nebenanlage nach Artikel 2 der Rohrleitungssicherheitsverordnung vom 4. Juni 2021 dürfen keine elektrischen Hochspannungsanlagen erstellt werden.\n6 Der Nachweis der Einhaltung der zulässigen Berührungsspannungen ist der Kontrollstelle im Rahmen des Plangenehmigungsgesuches oder auf Verlangen vorzulegen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-123.fr.json","api_md":"/api/v1/ch/lev/art-123.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_123","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-123","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_123","fussnoten":[{"marker":"38","nummer":38,"text":"Nouvelle teneur selon l’annexe 2 ch. 2 de l’O du 4 juin 2021 concernant les prescriptions de sécurité pour les installations de transport par conduites, en vigueur depuis le 1er juil. 2021 (RO 2021 348)."},{"marker":"39","nummer":39,"text":"RS 746.1"},{"marker":"40","nummer":40,"text":"RS 734.2"},{"marker":"41","nummer":41,"text":"RS 746.12"}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_5","num":"5. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Rohrleitungsanlagen"}],"id":"ch/lev/art-123","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-123/fr/","kennung":"ch/lev/art-123","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 123","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"06878db6f1a5bea4f078e7dd8b114a5ca7aa402b83d51c2488490c0977ce9083","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-123","titel":"Installations de transport par conduites souterraines et installations annexes","typ":"stelle","url":"/ch/lev/art-123/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Pour l’établissement de lignes électriques à une distance de moins de 30 m de conduites soumises à la loi du 4 octobre 1963 sur les installations de transport par conduites, on examinera:\na. si les tensions admissibles conformément à l’annexe 4 de l’ordonnance du 30 mars 1994 sur le courant fort ne sont pas dépassées sur l’installation de transport par conduites;\nb. quelles sont les mesures de protection adéquates à prendre.\n2 On examinera uniquement les installations de télécommunication et de télécommande si la conduite:\na. est posée directement dans la terre, sans isolation électrique\nb. est mise à terre sur le tronçon parallèle, ou\nc. est en matériau électriquement non conducteur.\n3 On ne procédera à aucun examen si le point neutre du réseau à haute tension est isolé de la terre ou muni d’une inductance de mise à la terre.\n4 On tiendra compte du danger de corrosion imputable au courant continu et alternatif.\n5 Aucune installation électrique à haute tension ne peut être établie dans le périmètre de protection d’une installation annexe visée à l’art. 2 de l’ordonnance du 4 juin 2021 sur la sécurité des installations de transport par conduite.\n6 La preuve du respect des tensions de contact admissibles doit être apportée à l’organe de contrôle dans le cadre de la demande d’approbation des plans ou à sa demande."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-123.it.json","api_md":"/api/v1/ch/lev/art-123.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_123","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-123","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_123","fussnoten":[{"marker":"40","nummer":40,"text":"Nuovo testo giusta l’all. 2 n. 2 dell’O del 4 giu. 2021 sulla sicurezza degli impianti di trasporto in condotta, in vigore dal 1° lug. 2021 (RU 2021 348)."},{"marker":"41","nummer":41,"text":"RS 746.1"},{"marker":"42","nummer":42,"text":"RS 734.2"},{"marker":"43","nummer":43,"text":"RS 746.12"}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_5","num":"5. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Rohrleitungsanlagen"}],"id":"ch/lev/art-123","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-123/it/","kennung":"ch/lev/art-123","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 123","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"fcea336b8be83c245322bdb60a3df88ad2531dfe9fbcf14266bd4d8a8609a643","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-123","titel":"Condotte interrate e impianti accessori","typ":"stelle","url":"/ch/lev/art-123/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Per la costruzione di linee elettriche a una distanza inferiore a 30 metri da condotte sottoposte alla legge del 4 ottobre 1963 sugli impianti di trasporto in condotta occorre accertare:\na. se nell’impianto di trasporto in condotta non sono superate le tensioni ammissibili secondo l’appendice 4 dell’ordinanza del 30 marzo 1994 sulla corrente forte;\nb. le misure di protezione da adottare.\n2 L’accertamento va limitato agli impianti di telecomunicazione e di comando a distanza se la condotta:\na. è posata direttamente nel terreno senza isolazione elettrica;\nb. è interrata lungo la tratta in parallelo; oppure\nc. è costituita da materiale non conduttore.\n3 L’accertamento diventa superfluo se il neutro della rete ad alta tensione è isolato dalla terra oppure dotato di bobina di estinzione.\n4 Occorre prendere in considerazione il pericolo di corrosione da corrente continua e da corrente alternata.\n5 Nel perimetro di protezione di un impianto accessorio secondo l’articolo 2 dell’ordinanza del 4 giugno 2021 sulla sicurezza degli impianti di trasporto in condotta, non si possono costruire impianti elettrici ad alta tensione.\n6 La prova del rispetto delle tensioni di contatto ammissibili deve essere trasmessa all’organo di controllo nel quadro della domanda di approvazione dei piani o su richiesta."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-124.de.json","api_md":"/api/v1/ch/lev/art-124.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_124","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-124","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_124","fussnoten":[{"marker":"43","nummer":43,"text":"Aufgehoben durch Anhang 2 Ziff. 2 der Rohrleitungssicherheitsverordnung vom 4. Juni 2021, mit Wirkung seit 1. Juli 2021 (AS 2021 348)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_5","num":"5. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Rohrleitungsanlagen"}],"id":"ch/lev/art-124","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-124/de/","kennung":"ch/lev/art-124","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 124","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"bf1b6af4ef921c4462e4f27c74b970c66ac4998a2aa2fe5b151ab8360502954b","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-124","titel":"","typ":"stelle","url":"/ch/lev/art-124/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Aufgehoben durch Anhang 2 Ziff. 2 der Rohrleitungssicherheitsverordnung vom 4. Juni 2021, mit Wirkung seit 1. Juli 2021 (AS 2021 348)."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-124.fr.json","api_md":"/api/v1/ch/lev/art-124.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_124","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-124","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_124","fussnoten":[{"marker":"42","nummer":42,"text":"Abrogé par l’annexe 2 ch. 2 de l’O du 4 juin 2021 concernant les prescriptions de sécurité pour les installations de transport par conduites, avec effet au 1er juil. 2021 (RO 2021 348)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_5","num":"5. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Rohrleitungsanlagen"}],"id":"ch/lev/art-124","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-124/fr/","kennung":"ch/lev/art-124","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 124","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"930a43c605ed30fd6a6cec03c4611ffe35a6f0aaf4974b1911c9def72e4f5ac6","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-124","titel":"","typ":"stelle","url":"/ch/lev/art-124/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Abrogé par l’annexe 2 ch. 2 de l’O du 4 juin 2021 concernant les prescriptions de sécurité pour les installations de transport par conduites, avec effet au 1er juil. 2021 (RO 2021 348)."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-124.it.json","api_md":"/api/v1/ch/lev/art-124.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_124","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-124","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_124","fussnoten":[{"marker":"44","nummer":44,"text":"Abrogato dall’all. 2 n. 2 dell’O del 4 giu. 2021 sulla sicurezza degli impianti di trasporto in condotta, con effetto dal 1° lug. 2021 (RU 2021 348)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_5","num":"5. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Rohrleitungsanlagen"}],"id":"ch/lev/art-124","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-124/it/","kennung":"ch/lev/art-124","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 124","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"409d980518b18d298ddf5f3099ebb4cb85e228f058f8290e670f6e128f8b4d46","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-124","titel":"","typ":"stelle","url":"/ch/lev/art-124/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Abrogato dall’all. 2 n. 2 dell’O del 4 giu. 2021 sulla sicurezza degli impianti di trasporto in condotta, con effetto dal 1° lug. 2021 (RU 2021 348)."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-125.de.json","api_md":"/api/v1/ch/lev/art-125.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_125","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-125","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_125","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_5","num":"5. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Rohrleitungsanlagen"}],"id":"ch/lev/art-125","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-125/de/","kennung":"ch/lev/art-125","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 125","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"18e82e2fdfb9107e49a3705bd41bebf34af141edb57640efade3ccc635a163f6","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-125","titel":"Oberirdische Rohrleitungen","typ":"stelle","url":"/ch/lev/art-125/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Bei Annäherungen und Parallelführungen von Hochspannungsfreileitungen mit oberirdischen und von der Erde isolierten Rohrleitungen sind Schutzmassnahmen zu treffen, wenn beim Berühren der Rohrleitung spürbare Ableitströme entstehen können."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-125.fr.json","api_md":"/api/v1/ch/lev/art-125.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_125","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-125","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_125","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_5","num":"5. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Rohrleitungsanlagen"}],"id":"ch/lev/art-125","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-125/fr/","kennung":"ch/lev/art-125","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 125","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"fc99fae670e5bca1367fd00f3860ecbc1e579269a2887a9607886eb9bbc963fd","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-125","titel":"Conduites posées à ciel ouvert","typ":"stelle","url":"/ch/lev/art-125/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"En cas de rapprochement ou de parallélisme de lignes aériennes à haute tension avec des conduites posées à ciel ouvert et isolée de la terre, on prendra des mesures de protection si, au toucher de la conduite, des courants de fuite perceptibles peuvent apparaître."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-125.it.json","api_md":"/api/v1/ch/lev/art-125.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_125","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-125","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_125","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_5","num":"5. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Rohrleitungsanlagen"}],"id":"ch/lev/art-125","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-125/it/","kennung":"ch/lev/art-125","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 125","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"6dbe6aafa06d21487f500023aed6d644dd2397f82f6ec9437bb239ff280a010b","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-125","titel":"Condotte in superficie","typ":"stelle","url":"/ch/lev/art-125/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Nei casi di vicinanza e di parallelismo delle linee aeree ad alta tensione con condotte in superficie isolate dal terreno, si rendono necessarie misure protettive qualora, nel toccare la condotta, possano prodursi correnti di scarica avvertibili."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-126.de.json","api_md":"/api/v1/ch/lev/art-126.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_126","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-126","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_126","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_5","num":"5. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Rohrleitungsanlagen"}],"id":"ch/lev/art-126","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-126/de/","kennung":"ch/lev/art-126","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 126","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"5498a7ceb1333c3ce9cef9d6c55ae4f8fffc77cc91b40c3d0904b29af644e8b5","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-126","titel":"Elektrische Auftrennung","typ":"stelle","url":"/ch/lev/art-126/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Zwischen Erdungen oder geerdeten Teilen von elektrischen Leitungen oder Starkstromanlagen und Rohrleitungsanlagen dürfen keine metallenen Verbindungen bestehen, ausser beide Anlagen seien mit dem gleichen Erdungssystem verbunden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-126.fr.json","api_md":"/api/v1/ch/lev/art-126.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_126","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-126","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_126","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_5","num":"5. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Rohrleitungsanlagen"}],"id":"ch/lev/art-126","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-126/fr/","kennung":"ch/lev/art-126","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 126","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"18801b30015ead8be667a7dcbd4c3d73fa81db075f2832dfe646e96464b6a698","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-126","titel":"Séparation électrique","typ":"stelle","url":"/ch/lev/art-126/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Il ne doit y avoir aucune liaison métallique entre les terres, les éléments de lignes électriques mises à la terre ou les installations à courant fort et les installations de transport par conduites, sauf si les deux installations sont reliées au même système de mise à la terre."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-126.it.json","api_md":"/api/v1/ch/lev/art-126.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_126","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-126","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_126","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_5","num":"5. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Rohrleitungsanlagen"}],"id":"ch/lev/art-126","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-126/it/","kennung":"ch/lev/art-126","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 126","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"a8cfc816dc0f0aa8d5b7fb349578412b9e60aab1ce7b840aa8cb51abbd1d72f1","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-126","titel":"Separazione galvanica","typ":"stelle","url":"/ch/lev/art-126/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Tra le terre o le parti messe a terra delle linee elettriche, o di impianti a corrente forte, e gli impianti in condotta non devono esserci collegamenti metallici a meno che i due impianti non siano collegati alla stesso sistema di terre."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-127.de.json","api_md":"/api/v1/ch/lev/art-127.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_127","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-127","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_127","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_5","num":"5. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Rohrleitungsanlagen"}],"id":"ch/lev/art-127","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-127/de/","kennung":"ch/lev/art-127","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 127","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"d2e50e37d9756474cc3bab677de604afb83c5c052aab04a63280542cedc42632","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-127","titel":"Kreuzungen mit Freileitungen","typ":"stelle","url":"/ch/lev/art-127/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Rohrleitungen, die sich mit Starkstromfreileitungen kreuzen, müssen im Erdreich verlegt und mindestens 1 m überdeckt sein.\n2 Durch Tiefbauarbeiten dürfen weder die Standfestigkeit von Freileitungs-Tragwerken noch die Rohrleitungsanlagen beeinträchtigt werden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-127.fr.json","api_md":"/api/v1/ch/lev/art-127.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_127","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-127","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_127","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_5","num":"5. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Rohrleitungsanlagen"}],"id":"ch/lev/art-127","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-127/fr/","kennung":"ch/lev/art-127","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 127","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"8a8282b8bc2474d257e2db76486cb0816676c8ef6b429895dd0472632459d0f1","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-127","titel":"Croisements avec des lignes aériennes","typ":"stelle","url":"/ch/lev/art-127/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Aux points de croisements avec des lignes aériennes à courant fort, les conduites doivent être enfouies et leur recouvrement doit être au minimum de 1 m.\n2 Les travaux d’excavation ne doivent porter atteinte ni à la stabilité des supports de lignes aériennes ni aux installations de transport par conduites."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-127.it.json","api_md":"/api/v1/ch/lev/art-127.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_127","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-127","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_127","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_5","num":"5. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Rohrleitungsanlagen"}],"id":"ch/lev/art-127","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-127/it/","kennung":"ch/lev/art-127","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 127","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"aea1bccccd0a582de3e60a008c9eccd6a9f38304fd46766631df8374b0b1d0aa","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-127","titel":"Incroci con linee aeree","typ":"stelle","url":"/ch/lev/art-127/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Agli incroci con le linee aeree a corrente forte, le condotte devono essere interrate e coperte da almeno 1 m di terra;\n2 I lavori nel terreno non devono ridurre la stabilità dei sostegni delle linee aeree né danneggiare gli impianti di trasporto in condotta."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-128.de.json","api_md":"/api/v1/ch/lev/art-128.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_128","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-128","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_128","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_5","num":"5. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Rohrleitungsanlagen"}],"id":"ch/lev/art-128","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-128/de/","kennung":"ch/lev/art-128","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 128","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"772df9a14010561a8e442826c909b725c987b854eb305a631d3997bbc858f419","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-128","titel":"Nicht dem Rohrleitungsgesetz unterstellte Rohrleitungen","typ":"stelle","url":"/ch/lev/art-128/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Die Bestimmungen dieser Verordnung gelten sinngemäss, wenn Hochspannungsleitungen mit Rohrleitungsanlagen zusammentreffen, die zum Transport von brennbaren Gasen und Flüssigkeiten oder von Wärmemedien dienen und nicht dem Rohrleitungsgesetz unterstellt sind."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-128.fr.json","api_md":"/api/v1/ch/lev/art-128.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_128","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-128","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_128","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_5","num":"5. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Rohrleitungsanlagen"}],"id":"ch/lev/art-128","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-128/fr/","kennung":"ch/lev/art-128","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 128","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"4a8cdec2b9504e7ca777ee3002d4f79a5e9f85c7062e1b981b7ce207c7b2a95e","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-128","titel":"Conduites non soumises à la loi sur les installations de transport par conduites","typ":"stelle","url":"/ch/lev/art-128/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les dispositions de la présente ordonnance sont valables par analogie en cas de rencontre entre les lignes à haute tension et des installations de transport de gaz et de liquides inflammables par conduites ainsi que de liquides caloporteurs non soumises à la loi sur les installations de transport par conduites."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-128.it.json","api_md":"/api/v1/ch/lev/art-128.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_128","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-128","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_128","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_5","num":"5. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Rohrleitungsanlagen"}],"id":"ch/lev/art-128","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-128/it/","kennung":"ch/lev/art-128","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 128","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"537ce2e6f443ffabbdda6b3b17a7d2c27e3a2203a5e81292e083250b9d2ce87a","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-128","titel":"Impianti di trasporto in condotta non sottoposti alla legge","typ":"stelle","url":"/ch/lev/art-128/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Le disposizioni della presente ordinanza si applicano, per analogia, all’incontro delle linee ad alta tensione con impianti in condotta adibiti al trasporto di gas e di liquidi infiammabili o al teleriscaldamento e non sottoposti alla legge sugli impianti di trasporto in condotta."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-129.de.json","api_md":"/api/v1/ch/lev/art-129.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_129","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-129","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_129","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_6","num":"6. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Tankanlagen"}],"id":"ch/lev/art-129","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-129/de/","kennung":"ch/lev/art-129","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 129","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"7d9e5f60e6e9fc30a933baadcd43ef2094b3a9dc4434e65cb9a72c8d03398b02","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-129","titel":"Grundsatz","typ":"stelle","url":"/ch/lev/art-129/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Annäherungen, Parallelführungen und Kreuzungen von Freileitungen mit Tankanlagen sind nicht zulässig.\n2 Nicht als Tankanlagen gelten Heizöltanks in Häusern und ähnliche Kleinanlagen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-129.fr.json","api_md":"/api/v1/ch/lev/art-129.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_129","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-129","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_129","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_6","num":"6. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Tankanlagen"}],"id":"ch/lev/art-129","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-129/fr/","kennung":"ch/lev/art-129","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 129","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"60b219ed26bc9a3e7161a226ecdb6b5fe37b09787e32310bb47cefeea13697bd","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-129","titel":"Principe","typ":"stelle","url":"/ch/lev/art-129/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les rapprochements, les parallélismes et les croisements de lignes aériennes avec des dépôts de combustibles ou de carburants ne sont pas admis.\n2 Les citernes à mazout domestiques et les petites installations similaires ne sont pas considérées comme des dépôts de combustibles ou de carburants."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-129.it.json","api_md":"/api/v1/ch/lev/art-129.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_129","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-129","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_129","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_6","num":"6. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Tankanlagen"}],"id":"ch/lev/art-129","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-129/it/","kennung":"ch/lev/art-129","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 129","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"7d1739afbc5a05b78329958fa3655f87b8abfeb53fd9d5fb60653f6ba96db295","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-129","titel":"Principio","typ":"stelle","url":"/ch/lev/art-129/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le vicinanze, i parallelismi e gli incroci tra impianti di cisterne e linee aeree non sono ammessi.\n2 Le cisterne di olio da riscaldamento negli edifici ed i piccoli impianti similari non sono considerati impianti di cisterne."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-130.de.json","api_md":"/api/v1/ch/lev/art-130.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_130","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-130","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_130","fussnoten":[{"marker":"44","nummer":44,"text":"Fassung gemäss Anhang 2 Ziff. 2 der Rohrleitungssicherheitsverordnung vom 4. Juni 2021, in Kraft seit 1. Juli 2021 (AS 2021 348)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_6","num":"6. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Tankanlagen"}],"id":"ch/lev/art-130","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-130/de/","kennung":"ch/lev/art-130","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 130","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"5c68afe901944822e463f78f8e86b3d7cf5437cea09b9eda4857f0a4d31b0c7b","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-130","titel":"Abstand zu Unterflur-Tankanlagen","typ":"stelle","url":"/ch/lev/art-130/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Der Horizontalabstand zwischen Freileitungen und Unterflur-Tankanlagen muss mindestens 10 m betragen.\n2 Der Horizontalabstand zwischen Hochspannungskabelleitungen und Unterflur-Tankanlagen muss mindestens 10 m plus 0,5 m pro kA Erdschlussstrom betragen.\n3 Der Horizontalabstand zwischen Niederspannungskabelleitungen mit einer zusätzlichen Isolationsschicht und Unterflur-Tankanlagen muss mindestens 0,5 m (Erdschicht) betragen.\n4 Beträgt der Direktabstand zwischen Unterflur-Tankanlagen und Kabelleitungen im Erdreich weniger als 10 m, so sorgt der Inhaber der Kabelleitung dafür, dass entweichende brennbare Gase und Flüssigkeiten nicht über Kabelkanäle und Kabelrohre in Gebäude eindringen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-130.fr.json","api_md":"/api/v1/ch/lev/art-130.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_130","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-130","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_130","fussnoten":[{"marker":"43","nummer":43,"text":"Nouvelle teneur selon l’annexe 2 ch. 2 de l’O du 4 juin 2021 concernant les prescriptions de sécurité pour les installations de transport par conduites, en vigueur depuis le 1er juil. 2021 (RO 2021 348)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_6","num":"6. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Tankanlagen"}],"id":"ch/lev/art-130","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-130/fr/","kennung":"ch/lev/art-130","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 130","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"39ae31b088b2cdaad83dc85602efc59a9185e7aad4707495433055893d0f4b87","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-130","titel":"Distance entre les lignes et les dépôts souterrains de combustibles ou de carburants","typ":"stelle","url":"/ch/lev/art-130/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 La distance horizontale entre les lignes aériennes et les dépôts souterrains de combustibles ou de carburants doit être au minimum de 10 m.\n2 La distance horizontale entre les lignes en câble à haute tension et les dépôts souterrains de combustibles ou de carburants doit être au minimum de 10 m plus 0,5 m par kA de courant de court-circuit à la terre.\n3 La distance horizontale entre les lignes en câble à basse tension recouvertes d’une couche d’isolation supplémentaire et les dépôts souterrains de combustibles ou de carburants doit être au minimum de 0,5 m (couche de terre).\n4 Lorsque, dans le sol, la distance directe entre les dépôts souterrains de combustibles ou de carburants et les lignes en câble est inférieure à 10 m, le propriétaire de la ligne en câbles veille à ce que, en cas de fuite, il ne puisse y avoir aucune infiltration de gaz ou de liquides inflammables à l’intérieur des bâtiments au travers des caniveaux ou des tuyaux de câbles."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-130.it.json","api_md":"/api/v1/ch/lev/art-130.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_130","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-130","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_130","fussnoten":[{"marker":"45","nummer":45,"text":"Nuovo testo giusta l’all. 2 n. 2 dell’O del 4 giu. 2021 sulla sicurezza degli impianti di trasporto in condotta, in vigore dal 1° lug. 2021 (RU 2021 348)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_6","num":"6. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Tankanlagen"}],"id":"ch/lev/art-130","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-130/it/","kennung":"ch/lev/art-130","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 130","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"3ed266c5dae11978bab02f8f05abe79f4b1ceee2971bed98998cc4bae025cdb8","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-130","titel":"Distanze dagli impianti di cisterne interrati","typ":"stelle","url":"/ch/lev/art-130/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 La distanza orizzontale tra gli impianti di cisterne interrati e le linee aeree deve essere almeno di 10 metri.\n2 La distanza orizzontale tra linee in cavo ad alta tensione e impianti di cisterne interrati deve essere almeno di 10 metri, più 0,5 metri per ogni kA di corrente di circuito a terra.\n3 La distanza orizzontale tra linee in cavo a bassa tensione con uno strato isolante supplementare e impianti di cisterne interrati deve essere almeno di 0,5 metri (strato di terra).\n4 Se la distanza diretta tra impianti di cisterne interrati e linee in cavo interrate è inferiore a 10 metri, il gestore della linea in cavo deve fare in modo che i gas ed i liquidi infiammabili che possono fuoriuscire non vengano convogliati all’interno degli edifici attraverso i canali ed i tubi dei cavi."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-131.de.json","api_md":"/api/v1/ch/lev/art-131.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_131","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-131","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_131","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_6","num":"6. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Tankanlagen"}],"id":"ch/lev/art-131","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-131/de/","kennung":"ch/lev/art-131","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 131","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"a23fadac23975e516fe80a16dafb2fb95e6b07a03394c32625c902796cda2187","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-131","titel":"Abstand zu Überflur-Tankanlagen","typ":"stelle","url":"/ch/lev/art-131/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Der Horizontalabstand zwischen Freileitungen und Überflur-Tankanlagen muss betragen:\na. mindestens 15 m, wenn die Leiter im Annäherungsbereich auf gleicher Höhe oder tiefer liegen als die obersten Teile der Tankanlage;\nb. mindestens 10 m, wenn die Leiter im Annäherungsbereich höher liegen.\n2 Der Direktabstand von Leitern oder Luftkabeln zu Überflur-Tankanlagen muss bei Windauslenkung mindestens der Explosionszone der Tankanlage plus 0,01 m pro kV Nennspannung entsprechen.\n3 Der Horizontalabstand von Freileitungen zu allgemein zugänglichen Treibstofftankstellen muss mindestens 5 m betragen.\n4 Liegen die Leiter von Freileitungen wesentlich höher als die obersten Teile der Tankanlage, so kann die Kontrollstelle einen kleineren Horizontalabstand oder eine Überführung bewilligen, wenn eine Explosion oder ein Brand in der Tankanlage ausgeschlossen oder für die Freileitung ungefährlich ist. Die Kontrollstelle legt die zu treffenden Schutzmassnahmen fest."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-131.fr.json","api_md":"/api/v1/ch/lev/art-131.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_131","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-131","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_131","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_6","num":"6. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Tankanlagen"}],"id":"ch/lev/art-131","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-131/fr/","kennung":"ch/lev/art-131","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 131","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"2d763746902349cdd2ee63af25244c1e5f8ba77e02d2cf0567f3095f0635bea3","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-131","titel":"Distance entre les lignes et les dépôts de combustibles ou de carburants à ciel ouvert","typ":"stelle","url":"/ch/lev/art-131/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 La distance horizontale entre les lignes aériennes et les dépôts de combustibles ou de carburants à ciel ouvert doit être:\na. au minimum de 15 m lorsque la hauteur des conducteurs dans la zone de rapprochement est égale ou inférieure à celle des parties supérieures du dépôt;\nb. au minimum de 10 m lorsque la hauteur des conducteurs dans la zone de rapprochement est supérieure à celle des parties supérieures du dépôt.\n2 La distance directe entre les conducteurs ou les câbles aériens avec une déviation due au vent et les dépôts de combustibles ou de carburants à ciel ouvert doit être au minimum égale à l’étendue de la zone explosive du dépôt plus 0,01 m par kV de tension nominale.\n3 La distance horizontale entre les lignes aériennes et les stations-service publiques doit être au minimum de 5 m.\n4 Pour les lignes aériennes dont les conducteurs dépassent nettement la hauteur des parties supérieures des dépôts de combustibles ou de carburants, l’organe de contrôle peut autoriser des distances horizontales plus faibles ou le passage au-dessus des dépôts, pour autant qu’une explosion ou qu’un incendie dans le dépôt soient exclus ou qu’ils soient sans danger pour la ligne aérienne. L’organe de contrôle fixe les mesures de protection adéquates."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-131.it.json","api_md":"/api/v1/ch/lev/art-131.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_131","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-131","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_131","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_6","num":"6. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Tankanlagen"}],"id":"ch/lev/art-131","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-131/it/","kennung":"ch/lev/art-131","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 131","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"dd41a9cecfa1e6a9212b06194bd238fb6d3fd5e69e4f666e6734cc7e1041c82b","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-131","titel":"Distanze dagli impianti di cisterne allo scoperto","typ":"stelle","url":"/ch/lev/art-131/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 La distanza orizzontale tra le linee aeree e gli impianti di cisterne allo scoperto:\na. non deve essere inferiore a 15 m quando, nella zona di avvicinamento, i conduttori si trovano alla stessa altezza o più in basso delle parti più elevate dell’impianto di cisterna:\nb. non deve essere inferiore a 10 m quando nella zona di avvicinamento i conduttori sono situati più in alto.\n2 La distanza diretta dei conduttori o dei cavi aerei dall’impianto di cisterne allo scoperto deve almeno corrispondere, quando deviati dal vento, all’estensione della zona di esplosione dell’impianto, più 0,01 m per ogni kV di tensione nominale.\n3 La distanza orizzontale tra le linee aeree ed i distributori di carburante aperti al pubblico non deve essere inferiore a 5 m.\n4 Se le linee aeree sono tesate molto più in alto della parte più elevata dell’impianto di cisterna, l’organo di controllo può autorizzare distanze orizzontali più piccole oppure il sovrapassaggio quando si possa escludere l’esplosione o l’incendio dell’impianto di cisterne o la loro pericolosità per le linee aeree. L’organo di controllo fissa i provvedimenti di protezione da adottare."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-132.de.json","api_md":"/api/v1/ch/lev/art-132.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_132","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-132","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_132","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_6","num":"6. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Tankanlagen"}],"id":"ch/lev/art-132","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-132/de/","kennung":"ch/lev/art-132","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 132","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"47f59947297e90b4af59dc4fc7e136ac6bb1348511f064949070d5c4265f214d","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-132","titel":"Grössere Abstände aus feuerwehrtechnischen Gründen","typ":"stelle","url":"/ch/lev/art-132/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Die Kontrollstelle kann grössere Abstände und besondere Schutzmassnahmen vorschreiben, um zu verhindern, dass elektrische Leitungen bei einem Brand in Tankanlagen Lösch- und Kühlaktionen behindern oder das Löschpersonal gefährden.\n2 Besteht trotz Einhaltung des Horizontalabstandes die Gefahr, dass eine Explosion oder ein Brand in der Tankanlage die elektrische Starkstromanlage gefährdet oder teilweise zerstört, so sind mit den zuständigen Feuerwehrorganen Schutzmassnahmen zu vereinbaren.\n3 Elektrische Leitungen, die bei Katastrophenfällen in Tankanlagen unentbehrlich sind, müssen besonders geschützt werden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-132.fr.json","api_md":"/api/v1/ch/lev/art-132.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_132","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-132","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_132","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_6","num":"6. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Tankanlagen"}],"id":"ch/lev/art-132","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-132/fr/","kennung":"ch/lev/art-132","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 132","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"ff85ada1d2b3a9e2b4f81fa39ea5131816dd9c1392afed982490d6526fee505a","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-132","titel":"Distances plus grandes pour des motifs de lutte contre le feu","typ":"stelle","url":"/ch/lev/art-132/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Pour les motifs de lutte contre le feu, l’organe de contrôle peut prescrire de plus grandes distances ou des mesures de protection spéciales afin de ne pas entraver les opérations d’extinction et de refroidissement en cas d’incendie dans les dépôts de combustibles ou de carburants et de ne pas mettre en danger ceux qui les exécutent.\n2 Si malgré le respect de la distance horizontale prescrite, une explosion ou un incendie dans le dépôt de combustibles ou de carburants peut mettre en danger ou détruire partiellement l’installation électrique à courant fort, on conviendra avec les organes compétents de lutte contre le feu des mesures de protection adéquates.\n3 Les lignes électriques qui sont indispensables en cas de catastrophe dans les dépôts de combustibles ou de carburants doivent être spécialement protégées."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-132.it.json","api_md":"/api/v1/ch/lev/art-132.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_132","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-132","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_132","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_6","num":"6. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Tankanlagen"}],"id":"ch/lev/art-132","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-132/it/","kennung":"ch/lev/art-132","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 132","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"b1e3f5e6842699546884b6b87b0fcbe16c87d47aef180b7da6e6968f46d0f3d6","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-132","titel":"Distanze maggiori per esigenze antincendio","typ":"stelle","url":"/ch/lev/art-132/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 L’organo di controllo può prescrivere distanze maggiori e particolari misure di protezione per evitare che le linee elettriche possano ostacolare, nel caso di incendio dell’impianto, le operazioni di spegnimento e di raffreddamento oppure mettere in pericolo il personale partecipante.\n2 Se, malgrado il rispetto della distanza orizzontale prescritta, non si può escludere che una esplosione o un incendio nell’impianto di cisterne possa mettere in pericolo o danneggiare parzialmente l’impianto elettrico a corrente forte, bisogna concordare con gli organi competenti dei vigili del fuoco misure di protezione appropriate.\n3 Le linee elettriche indispensabili nel caso di catastrofe negli impianti di cisterne devono essere particolarmente protette."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-133.de.json","api_md":"/api/v1/ch/lev/art-133.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_133","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-133","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_133","fussnoten":[{"marker":"45","nummer":45,"text":"Aufgehoben durch Anhang 2 Ziff. 2 der Rohrleitungssicherheitsverordnung vom 4. Juni 2021, mit Wirkung seit 1. Juli 2021 (AS 2021 348)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_6","num":"6. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Tankanlagen"}],"id":"ch/lev/art-133","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-133/de/","kennung":"ch/lev/art-133","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 133","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"bf1b6af4ef921c4462e4f27c74b970c66ac4998a2aa2fe5b151ab8360502954b","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-133","titel":"","typ":"stelle","url":"/ch/lev/art-133/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Aufgehoben durch Anhang 2 Ziff. 2 der Rohrleitungssicherheitsverordnung vom 4. Juni 2021, mit Wirkung seit 1. Juli 2021 (AS 2021 348)."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-133.fr.json","api_md":"/api/v1/ch/lev/art-133.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_133","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-133","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_133","fussnoten":[{"marker":"44","nummer":44,"text":"Abrogé par l’annexe 2 ch. 2 de l’O du 4 juin 2021 concernant les prescriptions de sécurité pour les installations de transport par conduites, avec effet au 1er juil. 2021 (RO 2021 348)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_6","num":"6. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Tankanlagen"}],"id":"ch/lev/art-133","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-133/fr/","kennung":"ch/lev/art-133","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 133","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"930a43c605ed30fd6a6cec03c4611ffe35a6f0aaf4974b1911c9def72e4f5ac6","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-133","titel":"","typ":"stelle","url":"/ch/lev/art-133/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Abrogé par l’annexe 2 ch. 2 de l’O du 4 juin 2021 concernant les prescriptions de sécurité pour les installations de transport par conduites, avec effet au 1er juil. 2021 (RO 2021 348)."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-133.it.json","api_md":"/api/v1/ch/lev/art-133.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_133","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-133","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_133","fussnoten":[{"marker":"46","nummer":46,"text":"Abrogato dall’all. 2 n. 2 dell’O del 4 giu. 2021 sulla sicurezza degli impianti di trasporto in condotta, con effetto dal 1° lug. 2021 (RU 2021 348)."}],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_6","num":"6. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Tankanlagen"}],"id":"ch/lev/art-133","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-133/it/","kennung":"ch/lev/art-133","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 133","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"409d980518b18d298ddf5f3099ebb4cb85e228f058f8290e670f6e128f8b4d46","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-133","titel":"","typ":"stelle","url":"/ch/lev/art-133/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Abrogato dall’all. 2 n. 2 dell’O del 4 giu. 2021 sulla sicurezza degli impianti di trasporto in condotta, con effetto dal 1° lug. 2021 (RU 2021 348)."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-134.de.json","api_md":"/api/v1/ch/lev/art-134.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_134","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-134","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_134","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_6","num":"6. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Tankanlagen"}],"id":"ch/lev/art-134","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-134/de/","kennung":"ch/lev/art-134","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 134","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"843e1c07981a1209b06de16dff8ec31d497392d68d602902a04b6728a5d8bb71","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-134","titel":"Erdungsanlagen","typ":"stelle","url":"/ch/lev/art-134/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Tankanlagen sind gegen gefährliche kapazitive Aufladungen durch benachbarte Hochspannungsfreileitungen zu schützen.\n2 Zwischen Tankanlagen und geerdeten Teilen von elektrischen Leitungen, die nicht zu Tankanlagen gehören, dürfen keine metallenen Verbindungen bestehen.\n3 Tankanlagen dürfen sich nicht im gefährlichen Einflussbereich der Erdungen von elektrischen Leitungen befinden. Die Kontrollstelle kann Ausnahmen bewilligen.\n4 Bei Annäherungen im Erdboden muss der Direktabstand zwischen den mit der Tankanlage verbundenen Teilen und den Erdleitungen bzw. geerdeten Teilen fremder elektrischer Starkstromleitungen und -anlagen 0,5 m pro kA Erdschlussstrom, mindestens aber 10 m, betragen.\n5 Der Direktabstand nach Absatz 4 darf unterschritten werden, wenn die geerdeten Teile elektrischer Kabelleitungen oder die Teile der Tankanlage zusätzlich gegen das umgebende Erdreich elektrisch isoliert sind. Ein Direktabstand von 0,5 m (Erdschicht) darf aber nie unterschritten werden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-134.fr.json","api_md":"/api/v1/ch/lev/art-134.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_134","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-134","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_134","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_6","num":"6. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Tankanlagen"}],"id":"ch/lev/art-134","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-134/fr/","kennung":"ch/lev/art-134","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 134","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"68e4fe7a80e3dfacdcd50c67242c33c8150800b6a3c44f3d922f086b7df346d9","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-134","titel":"Installations de mise à la terre","typ":"stelle","url":"/ch/lev/art-134/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les dépôts de combustibles ou de carburants doivent être protégés contre des charges capacitives dangereuses dues à la proximité des lignes aériennes à haute tension.\n2 Il ne doit y avoir aucune liaison métallique entre les dépôts de combustibles ou de carburants et les éléments mis à la terre de lignes électriques étrangères à ces dépôts.\n3 Les dépôts de combustibles ou de carburants doivent se trouver à l’extérieur des zones d’influence dangereuses des mises à la terre de lignes électriques. L’organe de contrôle peut autoriser des dérogations.\n4 En cas de rapprochement dans le sol, la distance directe entre les éléments reliés au dépôt de combustibles ou de carburants et les conducteurs de terre, les éléments mis à la terre de lignes ou d’installations électriques à courant fort étrangères au dépôt doit être de 0,5 m par kA de courant de court-circuit à la terre, mais jamais inférieure à 10 m.\n5 La distance directe prescrite à l’al. 4 peut être plus faible si les éléments mis à la terre des lignes en câbles ou les éléments du dépôt de combustibles ou de carburants sont isolés électriquement de la terre avoisinante. Elle ne doit, toutefois, pas être inférieure à 0,5 m (couche de terre)."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-134.it.json","api_md":"/api/v1/ch/lev/art-134.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_134","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-134","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_134","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_2","num":"2. Titel:","titel":"Bauvorschriften"},{"ebene":"chapter","eid":"tit_2/chap_4","num":"4. Kapitel:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit anderen Anlagen"},{"ebene":"section","eid":"tit_2/chap_4/sec_6","num":"6. Abschnitt:","titel":"Annäherungen, Parallelführungen und Kreuzungen elektrischer Leitungen mit Tankanlagen"}],"id":"ch/lev/art-134","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-134/it/","kennung":"ch/lev/art-134","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 134","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"643ad9c0fb0bbfe6138eac93219f5c232a6c32df17c652816d705eb06d5fc45e","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-134","titel":"Impianti di messa a terra","typ":"stelle","url":"/ch/lev/art-134/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Gli impianti di cisterne devono essere protetti contro le cariche capacitive pericolose indotte dalle linee aeree ad alta tensione situate in prossimità.\n2 Non devono esservi collegamenti metallici tra gli impianti di cisterne e le parti messe a terra delle linee elettriche non appartenenti agli impianti.\n3 Gli impianti di cisterne non devono trovarsi all’interno della zona di influenza pericolosa delle terre delle linee elettriche. L’organo di controllo può autorizzare eccezioni.\n4 Nel caso di vicinanza nel terreno, la distanza diretta tra le parti collegate all’impianto di cisterne ed i conduttori di terra – o le parti messe a terra degli impianti elettrici a corrente forte di terzi – deve essere pari a 0,5 m per ogni kA di corrente di circuito a terra, ma non inferiore a 10 m.\n5 La distanza diretta di cui al capoverso 4 può essere ridotta quando le parti messe a terra delle linee elettriche in cavo o le parti dell’impianto di cisterne sono inoltre isolate elettricamente dal terreno circostante. La distanza diretta non può mai essere inferiore a 0,5 m (strato di terra)."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-135.de.json","api_md":"/api/v1/ch/lev/art-135.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_135","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-135","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_135","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-135","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-135/de/","kennung":"ch/lev/art-135","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 135","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"176068f9574ab54c44e274970e65349186abb8857935fd8b24e76b5b7a4b140f","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-135","titel":"Instandhaltung und Kontrollen","typ":"stelle","url":"/ch/lev/art-135/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Die Betriebsinhaber müssen die Leitungen dauernd in gutem Zustand halten und regelmässig kontrollieren.\n2 Sie müssen insbesondere Annäherungen, Parallelführungen und Kreuzungen von Freileitungen mit anderen Anlagen oder mit öffentlichen Strassen, Plätzen und schiffbaren Gewässern regelmässig überprüfen.\n3 Die Kontrollperioden dürfen bei Schwachstrom- und Niederspannungsfreileitungen fünf Jahre und bei Hochspannungsfreileitungen zwei Jahre nicht überschreiten."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-135.fr.json","api_md":"/api/v1/ch/lev/art-135.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_135","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-135","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_135","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-135","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-135/fr/","kennung":"ch/lev/art-135","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 135","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"d045d2b1eecf3e688e6e3d2bfc8c95ade6a46441862cbc8d5b36ee99c35b9e27","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-135","titel":"Entretien et contrôles","typ":"stelle","url":"/ch/lev/art-135/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les exploitants doivent maintenir constamment les lignes en bon état et les contrôler régulièrement.\n2 En particulier, ils doivent contrôler régulièrement les rapprochements, les parallélismes et les croisements de lignes aériennes avec les routes publiques, les places, les cours d’eau navigables et les autres infrastructures.\n3 La périodicité des contrôles ne doit pas excéder cinq ans pour les lignes aériennes à courant faible ou à basse tension, pas deux ans pour les lignes aériennes à haute tension."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-135.it.json","api_md":"/api/v1/ch/lev/art-135.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_135","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-135","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_135","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-135","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-135/it/","kennung":"ch/lev/art-135","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 135","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"62a2f360c4f28cc81de4037c156be0af7c9e9384b7e604732d15141a7a44d635","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-135","titel":"Manutenzione e controlli","typ":"stelle","url":"/ch/lev/art-135/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Gli esercenti devono mantenere le linee sempre in buono stato e sottoporle a controlli periodici.\n2 In particolare, essi devono verificare periodicamente le vicinanze, i parallelismi e gli incroci delle linee aeree con altri impianti o strade, piazze e acque navigabili pubbliche.\n3 Gli intervalli tra i controlli non devono superare 5 anni per le linee aeree a corrente debole ed a bassa tensione, e 2 anni per le linee aeree ad alta tensione."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-136.de.json","api_md":"/api/v1/ch/lev/art-136.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_136","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-136","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_136","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-136","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-136/de/","kennung":"ch/lev/art-136","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 136","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"24f15144d25dac220b49a8d538f3275a0e7cfa3685d9752857d52abebcd6e60b","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-136","titel":"Kontrollbericht","typ":"stelle","url":"/ch/lev/art-136/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Die Betriebsinhaber erstellen über jede Kontrolle einen Kontrollbericht. Darin beurteilen sie die Leitung und halten fest, wie und bis wann Mängel behoben werden.\n2 Die Kontrollberichte sind mindestens zehn Jahre aufzubewahren und auf Verlangen der Kontrollstelle vorzuweisen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-136.fr.json","api_md":"/api/v1/ch/lev/art-136.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_136","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-136","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_136","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-136","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-136/fr/","kennung":"ch/lev/art-136","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 136","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"6c4d264bf29e66af13c05bd7453c2779971eac22b121e2a4663a67249350680b","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-136","titel":"Rapport de contrôle","typ":"stelle","url":"/ch/lev/art-136/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les exploitants établissent un rapport pour chaque contrôle. Ils y inscrivent les défauts constatés sur la ligne, le genre des travaux d’entretien à entreprendre et les délais dont ils disposent.\n2 Les rapports de contrôle doivent être conservés pendant au minimum dix ans et présentés, sur demande, à l’organe de contrôle."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-136.it.json","api_md":"/api/v1/ch/lev/art-136.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_136","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-136","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_136","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-136","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-136/it/","kennung":"ch/lev/art-136","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 136","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"81068e02608a56e6ed3233f4a247ff105fcaca633abf22a4b8706465b0d57d61","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-136","titel":"Rapporto sui controlli","typ":"stelle","url":"/ch/lev/art-136/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Gli esercenti stendono un rapporto per ogni controllo effettuato. Nello stesso riportano un giudizio sulle linee, stabilendo le modalità ed i termini per l’eliminazione delle manchevolezze constatate.\n2 I rapporti sui controlli devono essere conservati almeno per 10 anni e presentati su richiesta agli organi di controllo."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-137.de.json","api_md":"/api/v1/ch/lev/art-137.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_137","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-137","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_137","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-137","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-137/de/","kennung":"ch/lev/art-137","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 137","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"1665adc7c314c75ad0bd52b7eb9feee8e91cc219cab49c62261ab985f6cc5645","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-137","titel":"Instruktion der Feuerwehr","typ":"stelle","url":"/ch/lev/art-137/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Die Betriebsinhaber von Starkstromleitungen der lokalen oder regionalen Stromversorgung orientieren und instruieren die Feuerwehr regelmässig über ihre Leitungen und Anlagen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-137.fr.json","api_md":"/api/v1/ch/lev/art-137.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_137","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-137","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_137","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-137","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-137/fr/","kennung":"ch/lev/art-137","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 137","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"1db9cabcdbd4d5fcf9b803158bd26ee58732a9a2d41bc8a8802541e4496f4d8c","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-137","titel":"Instruction du corps de sapeurs-pompiers","typ":"stelle","url":"/ch/lev/art-137/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les exploitants de lignes à courant fort pour la distribution d’énergie locale ou régionale informent et instruisent périodiquement les corps de sapeurs-pompiers au sujet de leurs lignes et de leurs installations."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-137.it.json","api_md":"/api/v1/ch/lev/art-137.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_137","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-137","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_137","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-137","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-137/it/","kennung":"ch/lev/art-137","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 137","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"036b63c548e619791c89b729e4c83ce2d2cf63054c98925f5982d00b022ad7e8","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-137","titel":"Istruzioni per i vigili del fuoco","typ":"stelle","url":"/ch/lev/art-137/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Gli esercenti delle linee aeree a corrente forte destinate all’alimentazione di corrente a livello locale o regionale informano ed istruiscono periodicamente i vigili del fuoco per quanto concerne i loro impianti e le loro linee."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-138.de.json","api_md":"/api/v1/ch/lev/art-138.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_138","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-138","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_138","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-138","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-138/de/","kennung":"ch/lev/art-138","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 138","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"f4d3a7ddc07022a53020da32dc55d1876d006e6297a39260733fe9be60b3b4f9","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-138","titel":"Ausser Betrieb gesetzte Leitungen","typ":"stelle","url":"/ch/lev/art-138/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Freileitungen, die für längere Zeit ausser Betrieb gesetzt sind, müssen geerdet und kurzgeschlossen werden.\n2 Ausser Betrieb gesetzte Freileitungen sind wie in Betrieb stehende Leitungen zu kontrollieren und instand zu halten."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-138.fr.json","api_md":"/api/v1/ch/lev/art-138.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_138","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-138","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_138","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-138","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-138/fr/","kennung":"ch/lev/art-138","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 138","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"183dd041061a3aa5bf26b116f4dd4deb6562adf2142c8806419c44c6337a7f3c","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-138","titel":"Lignes mise hors service","typ":"stelle","url":"/ch/lev/art-138/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Les lignes aériennes mises hors service pour une longue durée doivent être mises à la terre et en court-circuit.\n2 Les lignes aériennes mises hors service doivent être entretenues et contrôlées comme les lignes en service."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-138.it.json","api_md":"/api/v1/ch/lev/art-138.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_138","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-138","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_138","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-138","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-138/it/","kennung":"ch/lev/art-138","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 138","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"144149ac6f60157c5993b7b06cfa3e18260c6392b46be4dc0d5677ac03013040","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-138","titel":"Linee messe fuori servizio","typ":"stelle","url":"/ch/lev/art-138/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le linee aeree fuori servizio per lungo tempo devono essere messe a terra e cortocircuitate.\n2 Le linee aeree messe fuori servizio devono essere periodicamente sottoposte a controllo e manutenzione come le linee in esercizio."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-139.de.json","api_md":"/api/v1/ch/lev/art-139.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_139","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-139","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_139","fussnoten":[{"marker":"46","nummer":46,"text":"SR 734.2"}],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-139","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-139/de/","kennung":"ch/lev/art-139","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 139","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"6deb1d180c3ce5529b8e67988fe31e8127e87b84141cb1c4e7486748eedb0867","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-139","titel":"Arbeiten an Starkstromleitungen","typ":"stelle","url":"/ch/lev/art-139/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Für das Arbeiten an Starkstromleitungen gelten die Bestimmungen der Starkstromverordnung vom 30. März 1994."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-139.fr.json","api_md":"/api/v1/ch/lev/art-139.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_139","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-139","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_139","fussnoten":[{"marker":"45","nummer":45,"text":"RS 734.2"}],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-139","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-139/fr/","kennung":"ch/lev/art-139","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 139","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"6e1efa691e77a754462dd0275f5718e2c4bebcc4f295a1342af06f24800613be","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-139","titel":"Travaux sur les lignes à courant fort","typ":"stelle","url":"/ch/lev/art-139/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les travaux sur les lignes à courant fort sont régis par les dispositions de l’ordonnance du 30 mars 1994 sur le courant fort."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-139.it.json","api_md":"/api/v1/ch/lev/art-139.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_139","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-139","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_139","fussnoten":[{"marker":"47","nummer":47,"text":"RS 734.2"}],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-139","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-139/it/","kennung":"ch/lev/art-139","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 139","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"ec403878ca28e3009a050d331cb864ea0733e042eb366d0b63b533b27bd9bdf7","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-139","titel":"Lavori alle linee a corrente forte","typ":"stelle","url":"/ch/lev/art-139/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Per i lavori alle linee a corrente forte valgono le disposizioni dell’ordinanza del 30 marzo 1994 sugli impianti elettrici a corrente forte."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-140.de.json","api_md":"/api/v1/ch/lev/art-140.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_140","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-140","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_140","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-140","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-140/de/","kennung":"ch/lev/art-140","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 140","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"f538cc01195b453106a2a889bdfb7eb02c033be42657d9f3e231df234e940286","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-140","titel":"Arbeiten an Kabelleitungen","typ":"stelle","url":"/ch/lev/art-140/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Kabelleitungen, an denen gearbeitet werden soll sind vorgängig eindeutig zu identifizieren sowie freizuschalten und zu erden.\n2 Können unzulässige Berührungsspannungen auftreten, so müssen die freien Enden der leitenden Umhüllungen elektrisch leitend miteinander verbunden und an die Erdung der Arbeitsstelle angeschlossen werden.\n3 Ist die Sicherheit anderweitig gewährleistet, so kann auf die Freischaltung oder Erdung von Niederspannungs- und Schwachstromkabeln verzichtet werden."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-140.fr.json","api_md":"/api/v1/ch/lev/art-140.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_140","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-140","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_140","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-140","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-140/fr/","kennung":"ch/lev/art-140","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 140","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"18101cf23a413c6a308cfcb8e98b2a9039599d9bf32286a31bfd43e2f5b34a42","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-140","titel":"Travaux sur les lignes en câbles","typ":"stelle","url":"/ch/lev/art-140/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Avant d’entreprendre un quelconque travail sur les lignes en câbles, on les identifiera sans équivoque et les mettra hors tension et à la terre.\n2 Si des tensions de contact inadmissibles sont susceptibles d’apparaître, les extrémités libres des gaines conductrices devront être reliées électriquement entre elles et connectées avec la terre du chantier.\n3 On pourra renoncer à la mise hors tension ou à la mise à la terre pour des câbles à basse tension ou à courant faible si la sécurité est assurée autrement."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-140.it.json","api_md":"/api/v1/ch/lev/art-140.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_140","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-140","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_140","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-140","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-140/it/","kennung":"ch/lev/art-140","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 140","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"e3fe14347633b90398eeeb0d6ee546083b216c3e60a7d4baf515a9b14be40499","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-140","titel":"Lavori alle linee in cavo","typ":"stelle","url":"/ch/lev/art-140/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Le linee in cavo sulle quali si deve lavorare vanno preventivamente identificate con chiarezza, disinserite e messe a terra.\n2 Nel caso possano verificarsi tensioni di contatto inammissibili, bisogna collegare galvanicamente i terminali liberi degli involucri di materiale conduttore e allacciarli alla terra del posto di lavoro.\n3 Per i cavi a bassa tensione e a corrente debole, si può rinunciare al disinserimento o alla messa a terra qualora la sicurezza sia garantita in altro modo."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-141.de.json","api_md":"/api/v1/ch/lev/art-141.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_141","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-141","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_141","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-141","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-141/de/","kennung":"ch/lev/art-141","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 141","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"3cd4e68c8adb152906c33950e3247ff6838c30e10ca2885c55cf962a7414f0ff","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-141","titel":"Besondere Schutzmassnahmen","typ":"stelle","url":"/ch/lev/art-141/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Können bei Arbeiten an einer Leitung Gefahren für andere Anlagen entstehen oder von anderen Anlagen ausgehen, so verständigen sich die Inhaber rechtzeitig über die zu treffenden Schutzmassnahmen.\n2 Können sie sich nicht einigen, so entscheidet die Kontrollstelle über die Schutzmassnahmen.\n3 Bei drohender Gefahr kann die Kontrollstelle die sofortige Einstellung der Arbeiten oder des Betriebes der ihrer Aufsicht unterstellten Anlage anordnen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-141.fr.json","api_md":"/api/v1/ch/lev/art-141.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_141","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-141","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_141","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-141","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-141/fr/","kennung":"ch/lev/art-141","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 141","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"3bb36f7ec05f417975cb86e2efcd6418dbda378312f0251175b4edcdaf0570be","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-141","titel":"Mesures de protection particulières","typ":"stelle","url":"/ch/lev/art-141/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Lorsque des travaux sur une ligne peuvent entraîner des dangers pour d’autres installations ou être rendus dangereux par elles, les propriétaires doivent s’entendre par écrit en temps opportun sur les mesures de protection à prendre.\n2 Si aucun accord ne peut être trouvé, l’organe de contrôle décide des mesures de protection nécessaires.\n3 En cas de danger imminent, l’organe de contrôle peut ordonner la cessation immédiate des travaux ou de l’exploitation de l’installation placée sous sa surveillance."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-141.it.json","api_md":"/api/v1/ch/lev/art-141.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_141","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-141","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_141","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-141","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-141/it/","kennung":"ch/lev/art-141","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 141","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"0d834967c8691cfd8f4401b5f99480f7d60766e4dca0eec44a8ce4acdeb22dce","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-141","titel":"Misure di protezione particolari","typ":"stelle","url":"/ch/lev/art-141/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Se, durante i lavori ad una linea, possono nascere pericoli per altri o da altri impianti, gli esercenti si mettono tempestivamente d’accordo sulle misure protettive da adottare.\n2 Se non si raggiunge un accordo, l’organo di controllo decide in merito alle misure necessarie.\n3 In caso di pericolo incombente, l’organo di controllo può ordinare la sospensione immediata dei lavori o dell’esercizio dell’impianto sottoposto alla sua vigilanza."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-142.de.json","api_md":"/api/v1/ch/lev/art-142.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_142","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-142","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_142","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-142","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-142/de/","kennung":"ch/lev/art-142","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 142","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"1c4d010ecb84796b9d1ec97b052f76c339969679ac945137575db9cdbf7240ee","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-142","titel":"Massnahmen bei der Bergung von Reisenden aus Fahrzeugen von Luftseilbahnen","typ":"stelle","url":"/ch/lev/art-142/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"1 Können Personen bei Bergungsmassnahmen an einer Luftseilbahn durch eine Freileitung gefährdet werden, so haben sich die Betriebsinhaber beider Anlagen über das Vorgehen und über die sofortige Leitungsabschaltung schriftlich zu verständigen.\n2 Die schriftliche Vereinbarung muss vorliegen, bevor die später erstellte Anlage in Betrieb gesetzt wird. Sie ist der Kontrollstelle auf Verlangen vorzulegen und muss dem Betriebspersonal beider Anlagen jederzeit zugänglich sein.\n3 Die Betriebsinhaber müssen ihr Personal über das Vorgehen und die Massnahmen, die bei einer Bergung zu treffen sind, instruieren."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-142.fr.json","api_md":"/api/v1/ch/lev/art-142.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_142","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-142","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_142","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-142","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-142/fr/","kennung":"ch/lev/art-142","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 142","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"6d3a232d76fd10ef211d3951da19b5dc8d09570834b8434da5acf974df33d194","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-142","titel":"Mesures pour le sauvetage des passagers de téléphériques","typ":"stelle","url":"/ch/lev/art-142/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"1 Si une ligne aérienne constitue un danger pour le sauvetage des passagers d’un téléphérique, les exploitants des deux installations doivent établir une convention écrite sur la façon de procéder et sur le déclenchement immédiat de la ligne en cas d’urgence.\n2 Cette convention écrite doit être établie avant la mise en exploitation de la nouvelle installation. Elle doit pouvoir être présentée sur demande à l’organe de contrôle et être en permanence à la disposition du personnel de service des deux installations.\n3 Les exploitants doivent instruire leur personnel sur la façon de procéder et sur les mesures à prendre en cas de sauvetage."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-142.it.json","api_md":"/api/v1/ch/lev/art-142.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_142","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-142","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_142","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_3","num":"3. Titel:","titel":"Betrieb, Instandhaltung und Kontrolle von elektrischen Leitungen"}],"id":"ch/lev/art-142","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-142/it/","kennung":"ch/lev/art-142","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 142","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"324d99de25ce03215820b4f63cbeaa06d2cc985f9fe4ff0bc6b4611568a63aef","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-142","titel":"Misure per il recupero dei viaggiatori delle funivie","typ":"stelle","url":"/ch/lev/art-142/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"1 Se, nel corso delle operazioni di recupero dei viaggiatori di una funivia, gli stessi possono essere esposti a pericolo a causa della presenza di una linea aerea, gli esercenti dei due impianti devono accordarsi per iscritto sulla procedura da seguire e sul disinserimento immediato della linea.\n2 Detta convenzione scritta deve essere pronta prima che si dia inizio all’esercizio dell’impianto ultimo venuto, su richiesta, deve essere presentata all’organo di controllo ed essere ognora accessibile al personale di servizio dei due impianti.\n3 Gli esercenti devono istruire il loro personale sulla procedura da seguire e sulle misure da adottare nel caso di recupero in linea."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-143.de.json","api_md":"/api/v1/ch/lev/art-143.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_143","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-143","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_143","fussnoten":[{"marker":"47","nummer":47,"text":"Aufgehoben durch Ziff. IV 25 der V vom 22. Aug. 2007 zur formellen Bereinigung des Bundesrechts, mit Wirkung seit 1. Jan. 2008 (AS 2007 4477)."}],"gliederung":[{"ebene":"title","eid":"tit_4","num":"4. Titel:","titel":"Schlussbestimmungen"}],"id":"ch/lev/art-143","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-143/de/","kennung":"ch/lev/art-143","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 143","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"e5849081c975f6ba748bfbde1cd2a5c31893be897148b0ae6e3db600c9d6fea7","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-143","titel":"","typ":"stelle","url":"/ch/lev/art-143/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Aufgehoben durch Ziff. IV 25 der V vom 22. Aug. 2007 zur formellen Bereinigung des Bundesrechts, mit Wirkung seit 1. Jan. 2008 (AS 2007 4477)."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-143.fr.json","api_md":"/api/v1/ch/lev/art-143.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_143","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-143","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_143","fussnoten":[{"marker":"46","nummer":46,"text":"Abrogé par le ch. IV 25 de l’O du 22 août 2007 relative à la mise à jour formelle du droit fédéral, avec effet au 1er janv. 2008 (RO 2007 4477)."}],"gliederung":[{"ebene":"title","eid":"tit_4","num":"4. Titel:","titel":"Schlussbestimmungen"}],"id":"ch/lev/art-143","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-143/fr/","kennung":"ch/lev/art-143","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 143","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"ab69682170ffbe55b12837492bb23ca517bbc26d0810de4fd100a13ee8d67b9f","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-143","titel":"","typ":"stelle","url":"/ch/lev/art-143/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Abrogé par le ch. IV 25 de l’O du 22 août 2007 relative à la mise à jour formelle du droit fédéral, avec effet au 1er janv. 2008 (RO 2007 4477)."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-143.it.json","api_md":"/api/v1/ch/lev/art-143.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_143","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-143","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_143","fussnoten":[{"marker":"48","nummer":48,"text":"Abrogato dalla cifra IV n. 25 dell’O del 22 ago. 2007 concernente l’aggiornamento formale del diritto federale, con effetto dal 1° gen. 2008 (RU 2007 4477)."}],"gliederung":[{"ebene":"title","eid":"tit_4","num":"4. Titel:","titel":"Schlussbestimmungen"}],"id":"ch/lev/art-143","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-143/it/","kennung":"ch/lev/art-143","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 143","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"d14bdb9ff4927dbac88946139a9bf7bdd4cb7c993e2b76a340c28fa7c8a46931","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-143","titel":"","typ":"stelle","url":"/ch/lev/art-143/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Abrogato dalla cifra IV n. 25 dell’O del 22 ago. 2007 concernente l’aggiornamento formale del diritto federale, con effetto dal 1° gen. 2008 (RU 2007 4477)."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-144.de.json","api_md":"/api/v1/ch/lev/art-144.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_144","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-144","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_144","fussnoten":[{"marker":"48","nummer":48,"text":"[BS 4 848]"}],"gliederung":[{"ebene":"title","eid":"tit_4","num":"4. Titel:","titel":"Schlussbestimmungen"}],"id":"ch/lev/art-144","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-144/de/","kennung":"ch/lev/art-144","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 144","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"4b0bb24516f3d083a46d058119ccf1e1369898a8ee8cf838c2f3415e8f580ca9","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-144","titel":"Aufhebung bisherigen Rechts","typ":"stelle","url":"/ch/lev/art-144/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Die Verordnung vom 7. Juli 1933 über die Parallelführungen und Kreuzungen elektrischer Leitungen unter sich und mit Eisenbahnen wird aufgehoben."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-144.fr.json","api_md":"/api/v1/ch/lev/art-144.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_144","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-144","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_144","fussnoten":[{"marker":"47","nummer":47,"text":"[RS 4 884]"}],"gliederung":[{"ebene":"title","eid":"tit_4","num":"4. Titel:","titel":"Schlussbestimmungen"}],"id":"ch/lev/art-144","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-144/fr/","kennung":"ch/lev/art-144","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 144","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"3e1a1f5447b9a9c4279bf1442e574a23a91b46c70c96c14ecb71132ea085df2c","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-144","titel":"Abrogation du droit en vigueur","typ":"stelle","url":"/ch/lev/art-144/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"L’ordonnance du 7 juillet 1933 sur les parallélismes et les croisements de lignes électriques entre elles et avec les chemins de fer est abrogée."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-144.it.json","api_md":"/api/v1/ch/lev/art-144.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_144","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-144","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_144","fussnoten":[{"marker":"49","nummer":49,"text":"[CS 4 861]"}],"gliederung":[{"ebene":"title","eid":"tit_4","num":"4. Titel:","titel":"Schlussbestimmungen"}],"id":"ch/lev/art-144","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-144/it/","kennung":"ch/lev/art-144","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 144","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"4d142c4abc57aad241ef9c4602636fd6186d128f108e2ac739d5a83d859ea55c","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-144","titel":"Diritto previgente: abrogazione","typ":"stelle","url":"/ch/lev/art-144/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"L’ordinanza del 7 luglio 1933 sui parallelismi e gli incroci delle linee elettriche tra esse e con le ferrovie è abrogata."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-145.de.json","api_md":"/api/v1/ch/lev/art-145.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_145","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-145","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_145","fussnoten":[{"marker":"49","nummer":49,"text":"Die Änderung kann unter AS 1994 1233 konsultiert werden."}],"gliederung":[{"ebene":"title","eid":"tit_4","num":"4. Titel:","titel":"Schlussbestimmungen"}],"id":"ch/lev/art-145","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-145/de/","kennung":"ch/lev/art-145","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 145","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"b4935894c8ce16bde67bbffc672428b1533c4f1e1e8b1ce21a2933183db6bfa5","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-145","titel":"Änderung bisherigen Rechts","typ":"stelle","url":"/ch/lev/art-145/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"…"}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-145.fr.json","api_md":"/api/v1/ch/lev/art-145.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_145","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-145","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_145","fussnoten":[{"marker":"48","nummer":48,"text":"La mod. peut être consultée au RO 1994 1233."}],"gliederung":[{"ebene":"title","eid":"tit_4","num":"4. Titel:","titel":"Schlussbestimmungen"}],"id":"ch/lev/art-145","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-145/fr/","kennung":"ch/lev/art-145","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 145","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"b4935894c8ce16bde67bbffc672428b1533c4f1e1e8b1ce21a2933183db6bfa5","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-145","titel":"Modification du droit en vigueur","typ":"stelle","url":"/ch/lev/art-145/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"…"}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-145.it.json","api_md":"/api/v1/ch/lev/art-145.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_145","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-145","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_145","fussnoten":[{"marker":"50","nummer":50,"text":"La mod. può essere consultata alla RU 1994 1233."}],"gliederung":[{"ebene":"title","eid":"tit_4","num":"4. Titel:","titel":"Schlussbestimmungen"}],"id":"ch/lev/art-145","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-145/it/","kennung":"ch/lev/art-145","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 145","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"b4935894c8ce16bde67bbffc672428b1533c4f1e1e8b1ce21a2933183db6bfa5","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-145","titel":"Modificazione del diritto vigente","typ":"stelle","url":"/ch/lev/art-145/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"…"}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-146.de.json","api_md":"/api/v1/ch/lev/art-146.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_146","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-146","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_146","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_4","num":"4. Titel:","titel":"Schlussbestimmungen"}],"id":"ch/lev/art-146","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-146/de/","kennung":"ch/lev/art-146","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 146","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"61fc8bb4755350cacfd9a605cd95ff805af77f2a4e4ec1079572526abb7eb283","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-146","titel":"Übergangsbestimmung","typ":"stelle","url":"/ch/lev/art-146/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Planvorlagen für elektrische Leitungen, die bei Inkrafttreten dieser Verordnung bereits bei der Genehmigungsbehörde eingereicht sind, werden nach bestehendem Recht beurteilt. Werden die Pläne vollständig oder zu einem überwiegenden Teil überarbeitet, so sind sie nach neuem Recht zu beurteilen."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-146.fr.json","api_md":"/api/v1/ch/lev/art-146.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_146","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-146","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_146","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_4","num":"4. Titel:","titel":"Schlussbestimmungen"}],"id":"ch/lev/art-146","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-146/fr/","kennung":"ch/lev/art-146","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 146","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"ed3e202763b4d839f26be41a2c50afe81f7a17fabac5dc20defb334cf660a734","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-146","titel":"Dispositions transitoires","typ":"stelle","url":"/ch/lev/art-146/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les projets de lignes électriques déposés devant l’autorité d’approbation avant l’entrée en vigueur de la présente ordonnance seront examinés sous le régime du droit en vigueur. S’ils doivent ensuite être remaniés intégralement ou de façon importante, ils seront alors examinés sous le régime du nouveau droit."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-146.it.json","api_md":"/api/v1/ch/lev/art-146.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_146","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-146","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_146","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_4","num":"4. Titel:","titel":"Schlussbestimmungen"}],"id":"ch/lev/art-146","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-146/it/","kennung":"ch/lev/art-146","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 146","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"cae25b71d829c4fb8c249e392100254fdf364c100839df283e1daa4fc72f8a20","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-146","titel":"Disposizione transitoria","typ":"stelle","url":"/ch/lev/art-146/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"I progetti di piani per linee elettriche già presentati alle autorità di approvazione al momento dell’entrata in vigore della presente ordinanza sono esaminati in conformità alle esigenze del diritto previgente. Nel caso di rielaborazione completa o importante dei piani, essi saranno esaminati conformemente al nuovo diritto."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-146a.de.json","api_md":"/api/v1/ch/lev/art-146a.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_146_a","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-146a","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_146_a","fussnoten":[{"marker":"50","nummer":50,"text":"Eingefügt durch Ziff. I der V vom 25. Juni 2025, in Kraft seit 1. Aug. 2025 (AS 2025 451)."}],"gliederung":[{"ebene":"title","eid":"tit_4","num":"4. Titel:","titel":"Schlussbestimmungen"}],"id":"ch/lev/art-146a","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-146a/de/","kennung":"ch/lev/art-146a","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 146a","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"2e9291a4d4f694c4d9bf2bb9f33396fcb3630a48c9791502feb80e6ab2965307","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-146a","titel":"Übergangsbestimmung","typ":"stelle","url":"/ch/lev/art-146a/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"An folgenden Leitungen sind die Anpassungen zum Vogelschutz nach Artikel 30 Absatz 2 vorzunehmen:\na. Leitungen mit einer Spannung von 1 bis 36 kV: bis Ende 2035;\nb. Leitungen mit einer höheren Spannung als 36 kV bis 150 kV: bis Ende 2040."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-146a.fr.json","api_md":"/api/v1/ch/lev/art-146a.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_146_a","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-146a","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_146_a","fussnoten":[{"marker":"49","nummer":49,"text":"Introduit par le ch. I de l’O du 25 juin 2025, en vigueur depuis le 1er août 2025 (RO 2025 451)."}],"gliederung":[{"ebene":"title","eid":"tit_4","num":"4. Titel:","titel":"Schlussbestimmungen"}],"id":"ch/lev/art-146a","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-146a/fr/","kennung":"ch/lev/art-146a","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 146a","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"63b99fa3afb0e24f071807197ea177488cbbf5bcf75ff059c673336f5b613c95","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-146a","titel":"Disposition transitoire","typ":"stelle","url":"/ch/lev/art-146a/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"Les lignes suivantes doivent être adaptées conformément à l’art. 30, al. 2, à des fins de protection des oiseaux:\na. les lignes d’une tension de 1 à 36 kV, d’ici à fin 2035;\nb. les lignes d’une tension supérieure à 36 kV et inférieure ou égale à 150 kV, d’ici à fin 2040."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-146a.it.json","api_md":"/api/v1/ch/lev/art-146a.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_146_a","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-146a","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_146_a","fussnoten":[{"marker":"51","nummer":51,"text":"Introdotto dalla cifra I dell’O del 25 giu. 2025, in vigore dal 1° ago. 2025 (RU 2025 451)."}],"gliederung":[{"ebene":"title","eid":"tit_4","num":"4. Titel:","titel":"Schlussbestimmungen"}],"id":"ch/lev/art-146a","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-146a/it/","kennung":"ch/lev/art-146a","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 146a","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"ca3be207280bfec1e2caa8fc6673f5daa009e58617527ea8610096873a6761d0","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-146a","titel":"Disposizione transitoria","typ":"stelle","url":"/ch/lev/art-146a/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"Sulle linee seguenti devono essere realizzati gli adattamenti per la protezione dei volatili di cui all’articolo 30 capoverso 2:\na. linee con una tensione da 1 a 36 kV: entro la fine del 2035;\nb. linee con una tensione da 36 a 150 kV: entro la fine del 2040."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-147.de.json","api_md":"/api/v1/ch/lev/art-147.de.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_147","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-147","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_147","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_4","num":"4. Titel:","titel":"Schlussbestimmungen"}],"id":"ch/lev/art-147","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-147/de/","kennung":"ch/lev/art-147","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 147","quelle_sha":"e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695","schema":1,"sha256":"80b6e449224fc04efeb456f12531aa45e65d474b0c6bc9bb8cdc4bab1ab95545","sprache":"de","sr":"734.31","stand":"2025-08-01","stelle":"art-147","titel":"Inkrafttreten","typ":"stelle","url":"/ch/lev/art-147/de/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"LeV","werk_titel":"Verordnung über elektrische Leitungen","wortlaut":"Diese Verordnung tritt am 1. Juni 1994 in Kraft."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-147.fr.json","api_md":"/api/v1/ch/lev/art-147.fr.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_147","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-147","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_147","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_4","num":"4. Titel:","titel":"Schlussbestimmungen"}],"id":"ch/lev/art-147","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-147/fr/","kennung":"ch/lev/art-147","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 147","quelle_sha":"572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d","schema":1,"sha256":"2f1a4258f0051cb3124e2956d21a1e143982dad8de6670caf6c208d42d0e889f","sprache":"fr","sr":"734.31","stand":"2025-08-01","stelle":"art-147","titel":"Entrée en vigueur","typ":"stelle","url":"/ch/lev/art-147/fr/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordonnance sur les lignes électriques","wortlaut":"La présente ordonnance entre en vigueur le 1er juin 1994."}
{"$schema":"https://verbaipsa.org/api/v1/schema/stelle.schema.json","amtlich":false,"api_json":"/api/v1/ch/lev/art-147.it.json","api_md":"/api/v1/ch/lev/art-147.it.md","edition":"Fedlex, Systematische Rechtssammlung des Bundes","edition_id":"fedlex-sr","eid":"art_147","extraktionsregel":"akn-kanon-v1","fassung_kennung":"ch/lev/2025-08-01/art-147","fundstelle":"https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_147","fussnoten":[],"gliederung":[{"ebene":"title","eid":"tit_4","num":"4. Titel:","titel":"Schlussbestimmungen"}],"id":"ch/lev/art-147","ist_geltend":true,"kanonische_url":"https://verbaipsa.org/ch/lev/art-147/it/","kennung":"ch/lev/art-147","lizenz":"gemeinfrei, Art. 5 URG","num":"Art. 147","quelle_sha":"86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e","schema":1,"sha256":"c6ba862a63fd2df9a96fcbdc4b94b3725fff676454d1d9a5fbffd4965e853b70","sprache":"it","sr":"734.31","stand":"2025-08-01","stelle":"art-147","titel":"Entrata in vigore","typ":"stelle","url":"/ch/lev/art-147/it/","werk_id":"ch/lev","werk_kennung":"lev","werk_kurztitel":"OLEl","werk_titel":"Ordinanza sulle linee elettriche","wortlaut":"La presente ordinanza entra in vigore il 1° giugno 1994."}
