  "$schema": "https://verbaipsa.org/api/v1/schema/stelle-buendel.schema.json",
  "amtlich": false,
  "api_json": "/api/v1/ch/lev/art-21.json",
  "api_md": "/api/v1/ch/lev/art-21.md",
  "edition": "Fedlex, Systematische Rechtssammlung des Bundes",
  "edition_id": "fedlex-sr",
  "eid": "art_21",
  "extraktionsregel": "akn-kanon-v1",
  "fassung_kennung": "ch/lev/2025-08-01/art-21",
  "fassungen": {
    "de": {
      "api_json": "/api/v1/ch/lev/art-21.de.json",
      "api_md": "/api/v1/ch/lev/art-21.de.md",
      "fundstelle": "https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_21",
      "fussnoten": [],
      "kanonische_url": "https://verbaipsa.org/ch/lev/art-21/de/",
      "num": "Art. 21",
      "quelle_sha": "e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695",
      "sha256": "29a23c494f48add43dae5e30f7b551ac9782afea11a572572f0b409441bc45aa",
      "sprache": "de",
      "titel": "Isolatoren",
      "url": "/ch/lev/art-21/de/",
      "wortlaut": "1 Die Mindestbruchkraft von Stab‑, Stütz- und Stützenisolatoren aus keramischen Werkstoffen oder aus Glas muss mindestens 2,8 mal grösser sein als die grössten statischen Belastungen.\n2 Verbundisolatoren aus Kunststoff müssen witterungsbeständig und gegen UV-Strahlung resistent sein."
    },
    "fr": {
      "api_json": "/api/v1/ch/lev/art-21.fr.json",
      "api_md": "/api/v1/ch/lev/art-21.fr.md",
      "fundstelle": "https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_21",
      "fussnoten": [],
      "kanonische_url": "https://verbaipsa.org/ch/lev/art-21/fr/",
      "num": "Art. 21",
      "quelle_sha": "572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d",
      "sha256": "2707877805aedd6538d698c5b19ff07bd98985abe7c34d377d8f192d3f61694c",
      "sprache": "fr",
      "titel": "Isolateurs",
      "url": "/ch/lev/art-21/fr/",
      "wortlaut": "1 La charge de rupture minimale des isolateurs en céramique ou en verre, qu’ils soient à long fût, supports ou rigides à tige, doit présenter un coefficient de sécurité d’au moins 2,8 par rapport aux charges statiques maximales.\n2 Les isolateurs composites en matière synthétique doivent être résistants aux intempéries et au rayonnement ultraviolet."
    },
    "it": {
      "api_json": "/api/v1/ch/lev/art-21.it.json",
      "api_md": "/api/v1/ch/lev/art-21.it.md",
      "fundstelle": "https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_21",
      "fussnoten": [],
      "kanonische_url": "https://verbaipsa.org/ch/lev/art-21/it/",
      "num": "Art. 21",
      "quelle_sha": "86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e",
      "sha256": "6ec1e26052d7b2e7bf98bfb4b0d9ca7efc9372ff60e538302651eaeb20f71313",
      "sprache": "it",
      "titel": "Isolatori",
      "url": "/ch/lev/art-21/it/",
      "wortlaut": "1 Il carico di rottura minimo degli isolatori a bastone, degli isolatori rigidi a perno e degli isolatori rigidi a base, di materiali ceramici o di vetro, deve essere almeno pari a 2,8 volte la sollecitazione statica massima.\n2 Gli isolatori compositi di materiale sintetico devono resistere alle intemperie ed all’azione dei raggi ultravioletti."
    }
  },
  "id": "ch/lev/art-21",
  "ist_geltend": true,
  "kanonische_url": "https://verbaipsa.org/ch/lev/art-21/",
  "kennung": "ch/lev/art-21",
  "lizenz": "gemeinfrei, Art. 5 URG",
  "schema": 1,
  "sprachen": [
    "de",
    "fr",
    "it"
  ],
  "sr": "734.31",
  "stand": "2025-08-01",
  "stelle": "art-21",
  "typ": "stelle_buendel",
  "url": "/ch/lev/art-21/",
  "werk_id": "ch/lev",
  "werk_kennung": "lev"
}