{
  "$schema": "https://verbaipsa.org/api/v1/schema/stelle-buendel.schema.json",
  "amtlich": false,
  "api_json": "/api/v1/ch/lev/art-105.json",
  "api_md": "/api/v1/ch/lev/art-105.md",
  "edition": "Fedlex, Systematische Rechtssammlung des Bundes",
  "edition_id": "fedlex-sr",
  "eid": "art_105",
  "extraktionsregel": "akn-kanon-v1",
  "fassung_kennung": "ch/lev/2025-08-01/art-105",
  "fassungen": {
    "de": {
      "api_json": "/api/v1/ch/lev/art-105.de.json",
      "api_md": "/api/v1/ch/lev/art-105.de.md",
      "fundstelle": "https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_105",
      "fussnoten": [],
      "kanonische_url": "https://verbaipsa.org/ch/lev/art-105/de/",
      "num": "Art. 105",
      "quelle_sha": "e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695",
      "sha256": "9e57d2695149623b3f0d35ad4da1833a74861265549d235bea1dd058dd006c10",
      "sprache": "de",
      "titel": "Leitungstragwerke",
      "url": "/ch/lev/art-105/de/",
      "wortlaut": "1 Wo Leitungstragwerke durch Schiefstellung oder Umsturz den Seilbahnbetrieb unmittelbar gefährden können, sind Stützmasten nicht zulässig.\n2 Solche Tragwerke müssen den Anforderungen für Sondertragmasten (Anhang 14 Ziff. 4.3) entsprechen und mit besonderen Fundamenten nach Artikel 61 Absatz 5 ausgerüstet sein."
    },
    "fr": {
      "api_json": "/api/v1/ch/lev/art-105.fr.json",
      "api_md": "/api/v1/ch/lev/art-105.fr.md",
      "fundstelle": "https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_105",
      "fussnoten": [],
      "kanonische_url": "https://verbaipsa.org/ch/lev/art-105/fr/",
      "num": "Art. 105",
      "quelle_sha": "572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d",
      "sha256": "b988561a3671f9b13221797423a446d9f861b5498fd5f5f6d9e5963896daeb8e",
      "sprache": "fr",
      "titel": "Supports de lignes",
      "url": "/ch/lev/art-105/fr/",
      "wortlaut": "1 Les supports d’appui ne sont pas admis là où ils peuvent, en cas de chute ou d’inclinaison accidentelle, mettre directement en danger l’exploitation du téléphérique.\n2 Les supports de lignes doivent satisfaire aux exigences valables pour les supports porteurs spéciaux conformément à l’annexe 14, ch. 4.3, et être munis de fondations spéciales conformément à l’art. 61, al. 5."
    },
    "it": {
      "api_json": "/api/v1/ch/lev/art-105.it.json",
      "api_md": "/api/v1/ch/lev/art-105.it.md",
      "fundstelle": "https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_105",
      "fussnoten": [],
      "kanonische_url": "https://verbaipsa.org/ch/lev/art-105/it/",
      "num": "Art. 105",
      "quelle_sha": "86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e",
      "sha256": "60bca13e14ae48f3e282bfb671fce683c02417cc57b1a5ee4441c749e48af862",
      "sprache": "it",
      "titel": "Sostegni delle linee elettriche",
      "url": "/ch/lev/art-105/it/",
      "wortlaut": "1 Non sono ammessi sostegni ordinari che, in seguito a inclinazione o caduta, potrebbero mettere direttamente in pericolo l’esercizio dell’impianto di trasporto a fune.\n2 Questi sostegni devono soddisfare i requisiti richiesti ai sostegni portanti speciali (appendice 14, cifra 4.3) ed essere dotati di fondazioni speciali secondo l’articolo 61 capoverso 5."
    }
  },
  "id": "ch/lev/art-105",
  "ist_geltend": true,
  "kanonische_url": "https://verbaipsa.org/ch/lev/art-105/",
  "kennung": "ch/lev/art-105",
  "lizenz": "gemeinfrei, Art. 5 URG",
  "schema": 1,
  "sprachen": [
    "de",
    "fr",
    "it"
  ],
  "sr": "734.31",
  "stand": "2025-08-01",
  "stelle": "art-105",
  "typ": "stelle_buendel",
  "url": "/ch/lev/art-105/",
  "werk_id": "ch/lev",
  "werk_kennung": "lev"
}