{
  "$schema": "https://verbaipsa.org/api/v1/schema/stelle-buendel.schema.json",
  "amtlich": false,
  "api_json": "/api/v1/ch/lev/art-102.json",
  "api_md": "/api/v1/ch/lev/art-102.md",
  "edition": "Fedlex, Systematische Rechtssammlung des Bundes",
  "edition_id": "fedlex-sr",
  "eid": "art_102",
  "extraktionsregel": "akn-kanon-v1",
  "fassung_kennung": "ch/lev/2025-08-01/art-102",
  "fassungen": {
    "de": {
      "api_json": "/api/v1/ch/lev/art-102.de.json",
      "api_md": "/api/v1/ch/lev/art-102.de.md",
      "fundstelle": "https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/de#art_102",
      "fussnoten": [],
      "kanonische_url": "https://verbaipsa.org/ch/lev/art-102/de/",
      "num": "Art. 102",
      "quelle_sha": "e686ca24f689157def6ce2688fb152836bd48d965bd3052aa5f10d18d44d7695",
      "sha256": "87d4faa14694005f97fc923c8870f1dd590238869411aea6b055123fc4781c4e",
      "sprache": "de",
      "titel": "Kreuzungen von Bahnen ohne Fahrleitung",
      "url": "/ch/lev/art-102/de/",
      "wortlaut": "Kreuzen elektrische Leitungen Bahnen ohne Fahrleitung, so muss der Abstand zwischen den übergeführten Leitern und der Schienenoberkante mindestens 7 m plus 0,01 m pro kV der Nennspannung betragen."
    },
    "fr": {
      "api_json": "/api/v1/ch/lev/art-102.fr.json",
      "api_md": "/api/v1/ch/lev/art-102.fr.md",
      "fundstelle": "https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/fr#art_102",
      "fussnoten": [],
      "kanonische_url": "https://verbaipsa.org/ch/lev/art-102/fr/",
      "num": "Art. 102",
      "quelle_sha": "572b68d36afa8cec35ee62f7bf305453efc187f133d2f7d13d698df0d0fb328d",
      "sha256": "6dc43fbcbf042d13a51fa69495ad43863e5284f5f98a48995204c3a6a4bf0ff5",
      "sprache": "fr",
      "titel": "Croisement avec des installations de traction sans ligne de contact",
      "url": "/ch/lev/art-102/fr/",
      "wortlaut": "La distance entre le niveau supérieur des rails et les conducteurs les survolant doit être au minimum de 7 m plus 0,01 m par kV de tension nominale."
    },
    "it": {
      "api_json": "/api/v1/ch/lev/art-102.it.json",
      "api_md": "/api/v1/ch/lev/art-102.it.md",
      "fundstelle": "https://www.fedlex.admin.ch/eli/cc/1994/1233_1233_1233/it#art_102",
      "fussnoten": [],
      "kanonische_url": "https://verbaipsa.org/ch/lev/art-102/it/",
      "num": "Art. 102",
      "quelle_sha": "86a73f215b50d1dfb4faf1b76a260c9bb12e0b8bb7177ccfcf63305ebdaab22e",
      "sha256": "6a835fd958f0eab39356ccec71bd16a8f902c116568071f13e7c5f7342decd0f",
      "sprache": "it",
      "titel": "Incroci con ferrovie senza linea di contatto",
      "url": "/ch/lev/art-102/it/",
      "wortlaut": "Se le linee elettriche incrociano ferrovie senza linea di contatto, l’altezza sulla testa della rotaia dei conduttori sovrapassanti deve essere almeno pari a 7 m più 0,01 m per ogni kV di tensione nominale."
    }
  },
  "id": "ch/lev/art-102",
  "ist_geltend": true,
  "kanonische_url": "https://verbaipsa.org/ch/lev/art-102/",
  "kennung": "ch/lev/art-102",
  "lizenz": "gemeinfrei, Art. 5 URG",
  "schema": 1,
  "sprachen": [
    "de",
    "fr",
    "it"
  ],
  "sr": "734.31",
  "stand": "2025-08-01",
  "stelle": "art-102",
  "typ": "stelle_buendel",
  "url": "/ch/lev/art-102/",
  "werk_id": "ch/lev",
  "werk_kennung": "lev"
}